一种植入式定向多普勒流量计的详细描述。

Biotelemetry Pub Date : 1976-01-01
D Cathignol, J Y Chapelon, J Jossinet, B Lavandier, C Fourcade
{"title":"一种植入式定向多普勒流量计的详细描述。","authors":"D Cathignol,&nbsp;J Y Chapelon,&nbsp;J Jossinet,&nbsp;B Lavandier,&nbsp;C Fourcade","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A Doppler flowmeter and the necessary modifications for implantation are described in detail. Since only part of the electronics was implanted a phase-locked loop had to be introduced in order to keep the flow measurement directional. The proper working of the apparatus is demonstrated in vitro and in vivo. As an example the result of flow studies in the aorta and the pulmonary artery after homotransplantation of the lung in dogs are given.</p>","PeriodicalId":75602,"journal":{"name":"Biotelemetry","volume":"3 2","pages":"117-28"},"PeriodicalIF":0.0000,"publicationDate":"1976-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Detailed description of an implantable directional Doppler flowmeter.\",\"authors\":\"D Cathignol,&nbsp;J Y Chapelon,&nbsp;J Jossinet,&nbsp;B Lavandier,&nbsp;C Fourcade\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A Doppler flowmeter and the necessary modifications for implantation are described in detail. Since only part of the electronics was implanted a phase-locked loop had to be introduced in order to keep the flow measurement directional. The proper working of the apparatus is demonstrated in vitro and in vivo. As an example the result of flow studies in the aorta and the pulmonary artery after homotransplantation of the lung in dogs are given.</p>\",\"PeriodicalId\":75602,\"journal\":{\"name\":\"Biotelemetry\",\"volume\":\"3 2\",\"pages\":\"117-28\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1976-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biotelemetry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biotelemetry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

详细介绍了一种多普勒流量计和植入所需的改造。由于只植入了部分电子器件,因此必须引入锁相环以保持流量测量的方向性。该装置在体内和体外均能正常工作。本文给出了狗同种肺移植后主动脉和肺动脉的血流研究结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Detailed description of an implantable directional Doppler flowmeter.

A Doppler flowmeter and the necessary modifications for implantation are described in detail. Since only part of the electronics was implanted a phase-locked loop had to be introduced in order to keep the flow measurement directional. The proper working of the apparatus is demonstrated in vitro and in vivo. As an example the result of flow studies in the aorta and the pulmonary artery after homotransplantation of the lung in dogs are given.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信