热量测试解释中的误差来源。

G D Becker
{"title":"热量测试解释中的误差来源。","authors":"G D Becker","doi":"10.1177/019459987808600534","DOIUrl":null,"url":null,"abstract":"<p><p>Caloric testing plays a prominent role in evaluating the vestibular system. A unilateral reduced vestibular response (RVR) is a common abnormality and is consistent with peripheral vestibular pathology. An erroneous interpretation of RVR may be made due to the following circumstances: laboratory technique, the influence of directional preponderance (DP) on monothermal tests (MT), unilateral hyperactivity, or pseudocaloric (PC) nystagmus. These errors in interpretation may be avoided by (1) repeating any single irrigation that is significantly different from the other three, to rule out laboratory technical error; (2) performing bithermal (BT) testing exists, to eliminate the effects of directional preponderance; (3) observing that a right/left (R/L) difference is not due to unilateral hyperactivity, by noting absolute slow phase (SP) velocity; and (4) by demonstrating bidirectional sensitivity of the cupula before concluding that residual caloric function exists instead of no function.</p>","PeriodicalId":76297,"journal":{"name":"Otolaryngology","volume":"86 5","pages":"ORL-830-3"},"PeriodicalIF":0.0000,"publicationDate":"1978-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/019459987808600534","citationCount":"6","resultStr":"{\"title\":\"Sources of error in interpretation of caloric tests.\",\"authors\":\"G D Becker\",\"doi\":\"10.1177/019459987808600534\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Caloric testing plays a prominent role in evaluating the vestibular system. A unilateral reduced vestibular response (RVR) is a common abnormality and is consistent with peripheral vestibular pathology. An erroneous interpretation of RVR may be made due to the following circumstances: laboratory technique, the influence of directional preponderance (DP) on monothermal tests (MT), unilateral hyperactivity, or pseudocaloric (PC) nystagmus. These errors in interpretation may be avoided by (1) repeating any single irrigation that is significantly different from the other three, to rule out laboratory technical error; (2) performing bithermal (BT) testing exists, to eliminate the effects of directional preponderance; (3) observing that a right/left (R/L) difference is not due to unilateral hyperactivity, by noting absolute slow phase (SP) velocity; and (4) by demonstrating bidirectional sensitivity of the cupula before concluding that residual caloric function exists instead of no function.</p>\",\"PeriodicalId\":76297,\"journal\":{\"name\":\"Otolaryngology\",\"volume\":\"86 5\",\"pages\":\"ORL-830-3\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1978-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/019459987808600534\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Otolaryngology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/019459987808600534\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Otolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/019459987808600534","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

热量测试在评估前庭系统中起着重要的作用。单侧前庭反应减少(RVR)是一种常见的异常,与周围前庭病理一致。对RVR的错误解释可能是由于以下情况:实验室技术、定向优势(DP)对单温测试(MT)的影响、单侧多动或假性眼震(PC)。这些解释错误可以通过以下方式避免:(1)重复任何一个与其他三个明显不同的灌溉,以排除实验室技术错误;(2)进行双热(BT)测试,消除定向优势的影响;(3)通过观察绝对慢相(SP)速度,观察到右/左(R/L)差异不是由于单侧多动症引起的;(4)通过证明坩埚的双向敏感性,得出存在残余热函数而不是没有功能的结论。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Sources of error in interpretation of caloric tests.

Caloric testing plays a prominent role in evaluating the vestibular system. A unilateral reduced vestibular response (RVR) is a common abnormality and is consistent with peripheral vestibular pathology. An erroneous interpretation of RVR may be made due to the following circumstances: laboratory technique, the influence of directional preponderance (DP) on monothermal tests (MT), unilateral hyperactivity, or pseudocaloric (PC) nystagmus. These errors in interpretation may be avoided by (1) repeating any single irrigation that is significantly different from the other three, to rule out laboratory technical error; (2) performing bithermal (BT) testing exists, to eliminate the effects of directional preponderance; (3) observing that a right/left (R/L) difference is not due to unilateral hyperactivity, by noting absolute slow phase (SP) velocity; and (4) by demonstrating bidirectional sensitivity of the cupula before concluding that residual caloric function exists instead of no function.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信