高效液相色谱二极管阵列和蒸发光散射检测法用于剂量分段吉西他滨输液袋的性能评估。

IF 1.6 4区 医学 Q3 PHARMACOLOGY & PHARMACY
Thomas Stalder, Claire Andre, Maurad Ben Mahi, Lydie Lethier, Samuel Limat, Christine Legat, Yves Guillaume
{"title":"高效液相色谱二极管阵列和蒸发光散射检测法用于剂量分段吉西他滨输液袋的性能评估。","authors":"Thomas Stalder, Claire Andre, Maurad Ben Mahi, Lydie Lethier, Samuel Limat, Christine Legat, Yves Guillaume","doi":"10.1136/ejhpharm-2022-003540","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dose banding (DB) was used to optimise the individualisation of patient treatments with gemcitabine (Gem) in order to improve workload planning at the pharmacy of the University Hospital Centre of Besançon (UHCB). A new simple and fast high-performance liquid chromatographic (HPLC) method was also developed for the quantification of Gem without dilution of the infusion bags.</p><p><strong>Methods: </strong>Individual doses of Gem preparations were retrospectively analysed over a 1-year period to determine the frequency of prepared doses. Using a maximum gap of 7.5% around the doses chosen, the selected Gem standard doses were 1400 mg, 1600 mg, 1800 mg and 2000 mg. Following the DB scheme, the frequency of prescription of standard and individualised Gem doses was analysed over a period of 10 months. The four selected Gem standard doses were aseptically prepared in polyolefin infusion bags. Each series of 20 bags was stocked under refrigerated storage conditions (4°C) for up to 84 days. The quantification of Gem without dilution of the infusion bags was obtained by the development of a HPLC method coupled to a diode array detector (DAD) or an evaporative light scattering detector (ELSD).</p><p><strong>Results: </strong>During the 10-month period following implementation of the DB, 75.6% of the 1266 prescribed doses were covered by the four standardised preparations. The number of different Gem doses was reduced from 183 to 55. Concerning the Gem quantification, both heteroscedasticity and non-linearity were observed with DAD. Using an ELSD, the trueness values were between 98.59% and 101.52% with excellent repeatability values between 0.66% and 1.42%.</p><p><strong>Conclusion: </strong>A new HPLC method has been developed for the quantification of Gem without dilution of the infusion bags prepared in advance as a result of a target DB scheme successfully implemented in our pharmacy department.</p>","PeriodicalId":12050,"journal":{"name":"European journal of hospital pharmacy : science and practice","volume":" ","pages":"369-375"},"PeriodicalIF":1.6000,"publicationDate":"2024-06-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11265545/pdf/","citationCount":"0","resultStr":"{\"title\":\"Performance evaluation of the HPLC diode array and evaporative light scattering detection for the implementation of dose-banded gemcitabine infusion bags.\",\"authors\":\"Thomas Stalder, Claire Andre, Maurad Ben Mahi, Lydie Lethier, Samuel Limat, Christine Legat, Yves Guillaume\",\"doi\":\"10.1136/ejhpharm-2022-003540\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Dose banding (DB) was used to optimise the individualisation of patient treatments with gemcitabine (Gem) in order to improve workload planning at the pharmacy of the University Hospital Centre of Besançon (UHCB). A new simple and fast high-performance liquid chromatographic (HPLC) method was also developed for the quantification of Gem without dilution of the infusion bags.</p><p><strong>Methods: </strong>Individual doses of Gem preparations were retrospectively analysed over a 1-year period to determine the frequency of prepared doses. Using a maximum gap of 7.5% around the doses chosen, the selected Gem standard doses were 1400 mg, 1600 mg, 1800 mg and 2000 mg. Following the DB scheme, the frequency of prescription of standard and individualised Gem doses was analysed over a period of 10 months. The four selected Gem standard doses were aseptically prepared in polyolefin infusion bags. Each series of 20 bags was stocked under refrigerated storage conditions (4°C) for up to 84 days. The quantification of Gem without dilution of the infusion bags was obtained by the development of a HPLC method coupled to a diode array detector (DAD) or an evaporative light scattering detector (ELSD).</p><p><strong>Results: </strong>During the 10-month period following implementation of the DB, 75.6% of the 1266 prescribed doses were covered by the four standardised preparations. The number of different Gem doses was reduced from 183 to 55. Concerning the Gem quantification, both heteroscedasticity and non-linearity were observed with DAD. Using an ELSD, the trueness values were between 98.59% and 101.52% with excellent repeatability values between 0.66% and 1.42%.</p><p><strong>Conclusion: </strong>A new HPLC method has been developed for the quantification of Gem without dilution of the infusion bags prepared in advance as a result of a target DB scheme successfully implemented in our pharmacy department.</p>\",\"PeriodicalId\":12050,\"journal\":{\"name\":\"European journal of hospital pharmacy : science and practice\",\"volume\":\" \",\"pages\":\"369-375\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-06-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11265545/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of hospital pharmacy : science and practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1136/ejhpharm-2022-003540\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"PHARMACOLOGY & PHARMACY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of hospital pharmacy : science and practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1136/ejhpharm-2022-003540","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"PHARMACOLOGY & PHARMACY","Score":null,"Total":0}
引用次数: 0

摘要

背景:贝桑松大学医院中心(UHCB)药房采用剂量分段法(DB)优化吉西他滨(Gem)对患者的个体化治疗,以改善工作量规划。此外,还开发了一种简单快速的高效液相色谱(HPLC)新方法,用于在不稀释输液袋的情况下对吉西他滨进行定量:方法:对 1 年内 Gem 制剂的单个剂量进行回顾性分析,以确定配制剂量的频率。根据所选剂量周围 7.5% 的最大间隙,选定的宝石标准剂量为 1400 毫克、1600 毫克、1800 毫克和 2000 毫克。根据 DB 计划,对 10 个月内开具标准和个性化宝石剂量处方的频率进行了分析。所选的四种宝石标准剂量均无菌配制在聚烯烃输液袋中。每个系列 20 袋,在冷藏条件下(4°C)储存长达 84 天。通过开发一种与二极管阵列检测器 (DAD) 或蒸发光散射检测器 (ELSD) 相结合的高效液相色谱法,在不稀释输液袋的情况下对宝石进行定量:在实施 DB 后的 10 个月期间,四种标准化制剂覆盖了 1266 个处方剂量中的 75.6%。不同宝石剂量的数量从 183 种减少到 55 种。在宝石定量方面,使用 DAD 观察到了异方差和非线性现象。使用 ELSD,真实值介于 98.59% 和 101.52% 之间,重复性极佳,介于 0.66% 和 1.42% 之间:由于我们的药剂部门成功实施了目标 DB 计划,因此开发出了一种新的 HPLC 方法,无需稀释提前准备好的输液袋即可定量检测 Gem。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Performance evaluation of the HPLC diode array and evaporative light scattering detection for the implementation of dose-banded gemcitabine infusion bags.

Background: Dose banding (DB) was used to optimise the individualisation of patient treatments with gemcitabine (Gem) in order to improve workload planning at the pharmacy of the University Hospital Centre of Besançon (UHCB). A new simple and fast high-performance liquid chromatographic (HPLC) method was also developed for the quantification of Gem without dilution of the infusion bags.

Methods: Individual doses of Gem preparations were retrospectively analysed over a 1-year period to determine the frequency of prepared doses. Using a maximum gap of 7.5% around the doses chosen, the selected Gem standard doses were 1400 mg, 1600 mg, 1800 mg and 2000 mg. Following the DB scheme, the frequency of prescription of standard and individualised Gem doses was analysed over a period of 10 months. The four selected Gem standard doses were aseptically prepared in polyolefin infusion bags. Each series of 20 bags was stocked under refrigerated storage conditions (4°C) for up to 84 days. The quantification of Gem without dilution of the infusion bags was obtained by the development of a HPLC method coupled to a diode array detector (DAD) or an evaporative light scattering detector (ELSD).

Results: During the 10-month period following implementation of the DB, 75.6% of the 1266 prescribed doses were covered by the four standardised preparations. The number of different Gem doses was reduced from 183 to 55. Concerning the Gem quantification, both heteroscedasticity and non-linearity were observed with DAD. Using an ELSD, the trueness values were between 98.59% and 101.52% with excellent repeatability values between 0.66% and 1.42%.

Conclusion: A new HPLC method has been developed for the quantification of Gem without dilution of the infusion bags prepared in advance as a result of a target DB scheme successfully implemented in our pharmacy department.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.40
自引率
5.90%
发文量
104
审稿时长
6-12 weeks
期刊介绍: European Journal of Hospital Pharmacy (EJHP) offers a high quality, peer-reviewed platform for the publication of practical and innovative research which aims to strengthen the profile and professional status of hospital pharmacists. EJHP is committed to being the leading journal on all aspects of hospital pharmacy, thereby advancing the science, practice and profession of hospital pharmacy. The journal aims to become a major source for education and inspiration to improve practice and the standard of patient care in hospitals and related institutions worldwide. EJHP is the only official journal of the European Association of Hospital Pharmacists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信