{"title":"用小射频线圈对睾丸进行高分辨率磁共振成像。","authors":"Masayuki Yamaguchi, Kosuke Kojo, Mizuki Akatsuka, Tomoyuki Haishi, Tatsushi Kobayashi, Takahito Nakajima, Hiroyuki Nishiyama, Hirofumi Fujii","doi":"10.2463/mrms.tn.2021-0130","DOIUrl":null,"url":null,"abstract":"<p><p>We have developed a new device, consisting of a 3-cm RF coil and an immobilizer, to acquire high-resolution MR images of the testis. With the approval of our institutional review board, we conducted an MRI study on a cohort of healthy volunteers to test this device. With the participants in the supine position, we placed the dedicated immobilizer and RF coil on the scrotum for typically no more than 3 min. Subsequently, T2-weighted images were acquired with an in-plane resolution of 117 µm using a 3-T MR scanner and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) sequence. The total scan time ranged from 12 to 30 min (average 20 min). High-resolution MR images of the testis were acquired without deterioration by motion artifacts. Our results showed that the combined use of a small RF coil and an immobilizer is a feasible option for acquiring high-resolution MR images of the testis.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":"22 1","pages":"127-136"},"PeriodicalIF":4.6000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/23/2e/mrms-22-127.PMC9849421.pdf","citationCount":"0","resultStr":"{\"title\":\"High Resolution MR Imaging of the Testis Using a Small Radiofrequency Coil.\",\"authors\":\"Masayuki Yamaguchi, Kosuke Kojo, Mizuki Akatsuka, Tomoyuki Haishi, Tatsushi Kobayashi, Takahito Nakajima, Hiroyuki Nishiyama, Hirofumi Fujii\",\"doi\":\"10.2463/mrms.tn.2021-0130\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We have developed a new device, consisting of a 3-cm RF coil and an immobilizer, to acquire high-resolution MR images of the testis. With the approval of our institutional review board, we conducted an MRI study on a cohort of healthy volunteers to test this device. With the participants in the supine position, we placed the dedicated immobilizer and RF coil on the scrotum for typically no more than 3 min. Subsequently, T2-weighted images were acquired with an in-plane resolution of 117 µm using a 3-T MR scanner and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) sequence. The total scan time ranged from 12 to 30 min (average 20 min). High-resolution MR images of the testis were acquired without deterioration by motion artifacts. Our results showed that the combined use of a small RF coil and an immobilizer is a feasible option for acquiring high-resolution MR images of the testis.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":\"22 1\",\"pages\":\"127-136\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/23/2e/mrms-22-127.PMC9849421.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.2463/mrms.tn.2021-0130\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2463/mrms.tn.2021-0130","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0
摘要
我们开发了一种新设备,由一个3厘米的射频线圈和一个固定装置组成,用于获取睾丸的高分辨率磁共振图像。在我们机构审查委员会的批准下,我们对一组健康志愿者进行了核磁共振研究来测试这个设备。当参与者处于仰卧位时,我们将专用固定器和射频线圈放置在阴囊上通常不超过3分钟。随后,使用3- t MR扫描仪和周期性旋转重叠平行线增强重建(PROPELLER)序列获得平面内分辨率为117 μ m的t2加权图像。总扫描时间为12 ~ 30分钟(平均20分钟)。获得睾丸的高分辨率MR图像,无运动伪影恶化。我们的研究结果表明,结合使用一个小射频线圈和一个固定器是一个可行的选择,以获得高分辨率的睾丸磁共振图像。
High Resolution MR Imaging of the Testis Using a Small Radiofrequency Coil.
We have developed a new device, consisting of a 3-cm RF coil and an immobilizer, to acquire high-resolution MR images of the testis. With the approval of our institutional review board, we conducted an MRI study on a cohort of healthy volunteers to test this device. With the participants in the supine position, we placed the dedicated immobilizer and RF coil on the scrotum for typically no more than 3 min. Subsequently, T2-weighted images were acquired with an in-plane resolution of 117 µm using a 3-T MR scanner and the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) sequence. The total scan time ranged from 12 to 30 min (average 20 min). High-resolution MR images of the testis were acquired without deterioration by motion artifacts. Our results showed that the combined use of a small RF coil and an immobilizer is a feasible option for acquiring high-resolution MR images of the testis.