Luis G Rosifini Alves Rezende, Filipe J Shimaoka, Luiz G Mandarano-Filho, Nilton Mazzer
{"title":"第五掌颈矫正截骨髓内螺钉固定技术:技术与病例报告。","authors":"Luis G Rosifini Alves Rezende, Filipe J Shimaoka, Luiz G Mandarano-Filho, Nilton Mazzer","doi":"10.1097/BTH.0000000000000363","DOIUrl":null,"url":null,"abstract":"<p><p>Malunion of metacarpal fractures can result in severe functional and esthetic impairment to the patient, thus requiring surgical correction. Traditionally, the fixation methods most commonly used for these fractures are the Kirschner wires or the plates and screws. However, one of the options for the fixation of metacarpal fractures is intramedullary fixation with a headless screw. This minimally invasive method can also be used for corrective metacarpal osteotomies. It has the advantages of being a minimally invasive technique and allowing the early range of motion. This minimally invasive method can also be used to stabilize the corrective metacarpal osteotomies for malunion. This case report presents a minimally invasive technique for corrective dorsal metacarpal osteotomy and fixation with a headless intramedullary screw. This alternative fixation method has the advantage of low damage to soft tissues and good functional outcomes.</p>","PeriodicalId":39303,"journal":{"name":"Techniques in Hand and Upper Extremity Surgery","volume":"26 2","pages":"84-88"},"PeriodicalIF":0.0000,"publicationDate":"2022-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Corrective Fifth Metacarpal Neck Osteotomy and Intramedullary Screw Fixation Technique: Technique and Case Report.\",\"authors\":\"Luis G Rosifini Alves Rezende, Filipe J Shimaoka, Luiz G Mandarano-Filho, Nilton Mazzer\",\"doi\":\"10.1097/BTH.0000000000000363\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Malunion of metacarpal fractures can result in severe functional and esthetic impairment to the patient, thus requiring surgical correction. Traditionally, the fixation methods most commonly used for these fractures are the Kirschner wires or the plates and screws. However, one of the options for the fixation of metacarpal fractures is intramedullary fixation with a headless screw. This minimally invasive method can also be used for corrective metacarpal osteotomies. It has the advantages of being a minimally invasive technique and allowing the early range of motion. This minimally invasive method can also be used to stabilize the corrective metacarpal osteotomies for malunion. This case report presents a minimally invasive technique for corrective dorsal metacarpal osteotomy and fixation with a headless intramedullary screw. This alternative fixation method has the advantage of low damage to soft tissues and good functional outcomes.</p>\",\"PeriodicalId\":39303,\"journal\":{\"name\":\"Techniques in Hand and Upper Extremity Surgery\",\"volume\":\"26 2\",\"pages\":\"84-88\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Techniques in Hand and Upper Extremity Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1097/BTH.0000000000000363\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in Hand and Upper Extremity Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BTH.0000000000000363","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Corrective Fifth Metacarpal Neck Osteotomy and Intramedullary Screw Fixation Technique: Technique and Case Report.
Malunion of metacarpal fractures can result in severe functional and esthetic impairment to the patient, thus requiring surgical correction. Traditionally, the fixation methods most commonly used for these fractures are the Kirschner wires or the plates and screws. However, one of the options for the fixation of metacarpal fractures is intramedullary fixation with a headless screw. This minimally invasive method can also be used for corrective metacarpal osteotomies. It has the advantages of being a minimally invasive technique and allowing the early range of motion. This minimally invasive method can also be used to stabilize the corrective metacarpal osteotomies for malunion. This case report presents a minimally invasive technique for corrective dorsal metacarpal osteotomy and fixation with a headless intramedullary screw. This alternative fixation method has the advantage of low damage to soft tissues and good functional outcomes.
期刊介绍:
Techniques in Hand & Upper Extremity Surgery presents authoritative, practical information on today"s advances in hand and upper extremity surgery. It features articles by leading experts on the latest surgical techniques, the newest equipment, and progress in therapies for rehabilitation. The primary focus of the journal is hand surgery, but articles on the wrist, elbow, and shoulder are also included. Major areas covered include arthroscopy, microvascular surgery, plastic surgery, congenital anomalies, tendon and nerve disorders, trauma, and work-related injuries.