右至左房间分流大且右侧填充压力正常的室间隔分离所致缺氧1例。

IF 0.5 Q4 PERIPHERAL VASCULAR DISEASE
Nicolas W Shammas, Kathleen Keyes, William Witcik, Jon Robken, Edmund Coyne, Humphrey Wong
{"title":"右至左房间分流大且右侧填充压力正常的室间隔分离所致缺氧1例。","authors":"Nicolas W Shammas,&nbsp;Kathleen Keyes,&nbsp;William Witcik,&nbsp;Jon Robken,&nbsp;Edmund Coyne,&nbsp;Humphrey Wong","doi":"10.1055/s-0042-1749075","DOIUrl":null,"url":null,"abstract":"<p><p>Hypoxia secondary to right to left interatrial shunting in the setting of normal right-sided filling pressure is an uncommon clinical presentation. We present a case of persistent hypoxia irrespective of body position in a patient with a wide separation between the septum primum and secundum, creating a tunnel channeling flow from the right to the left atrium. Hypoxia resolved instantly following closure of the defect with an Amplatzer occluder under intracardiac echocardiography guidance. Although platypnea-orthodeoxia leads to hypoxia in the setting of normal right-sided filling pressures, the finding of a coexisting wide gap between the septum primum and secundum is likely to have worsened the hypoxia making it severe irrespective of body position. Closure of the interatrial septal defect led to immediate and sustained resolution of the hypoxia.</p>","PeriodicalId":13798,"journal":{"name":"International Journal of Angiology","volume":"32 3","pages":"202-205"},"PeriodicalIF":0.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421673/pdf/10-1055-s-0042-1749075.pdf","citationCount":"0","resultStr":"{\"title\":\"Hypoxia Due to a Large Right to Left Interatrial Shunt with Normal Right-Sided Filling Pressures in the Setting of a Separation between the Septum Primum and Secundum: A Case Report.\",\"authors\":\"Nicolas W Shammas,&nbsp;Kathleen Keyes,&nbsp;William Witcik,&nbsp;Jon Robken,&nbsp;Edmund Coyne,&nbsp;Humphrey Wong\",\"doi\":\"10.1055/s-0042-1749075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Hypoxia secondary to right to left interatrial shunting in the setting of normal right-sided filling pressure is an uncommon clinical presentation. We present a case of persistent hypoxia irrespective of body position in a patient with a wide separation between the septum primum and secundum, creating a tunnel channeling flow from the right to the left atrium. Hypoxia resolved instantly following closure of the defect with an Amplatzer occluder under intracardiac echocardiography guidance. Although platypnea-orthodeoxia leads to hypoxia in the setting of normal right-sided filling pressures, the finding of a coexisting wide gap between the septum primum and secundum is likely to have worsened the hypoxia making it severe irrespective of body position. Closure of the interatrial septal defect led to immediate and sustained resolution of the hypoxia.</p>\",\"PeriodicalId\":13798,\"journal\":{\"name\":\"International Journal of Angiology\",\"volume\":\"32 3\",\"pages\":\"202-205\"},\"PeriodicalIF\":0.5000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10421673/pdf/10-1055-s-0042-1749075.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Angiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0042-1749075\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Angiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0042-1749075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

摘要

在右侧充盈压力正常的情况下,继发于右至左心房分流的缺氧是一种罕见的临床表现。我们报告了一例与体位无关的持续性缺氧病例,患者的主隔膜和次隔膜之间有很大的分离,形成了一个从右心房到左心房的隧道通道。在超声心动图指导下用Amplatzer封堵器封闭缺损后,缺氧立即解决。虽然在正常右侧填充压力的情况下,肺动脉正常缺氧会导致缺氧,但发现原始隔膜和第二隔膜之间共存的宽间隙可能会加重缺氧,使其无论体位如何都变得严重。房间隔缺损的关闭导致缺氧的立即和持续的解决。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Hypoxia Due to a Large Right to Left Interatrial Shunt with Normal Right-Sided Filling Pressures in the Setting of a Separation between the Septum Primum and Secundum: A Case Report.

Hypoxia secondary to right to left interatrial shunting in the setting of normal right-sided filling pressure is an uncommon clinical presentation. We present a case of persistent hypoxia irrespective of body position in a patient with a wide separation between the septum primum and secundum, creating a tunnel channeling flow from the right to the left atrium. Hypoxia resolved instantly following closure of the defect with an Amplatzer occluder under intracardiac echocardiography guidance. Although platypnea-orthodeoxia leads to hypoxia in the setting of normal right-sided filling pressures, the finding of a coexisting wide gap between the septum primum and secundum is likely to have worsened the hypoxia making it severe irrespective of body position. Closure of the interatrial septal defect led to immediate and sustained resolution of the hypoxia.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Angiology
International Journal of Angiology PERIPHERAL VASCULAR DISEASE-
CiteScore
1.30
自引率
16.70%
发文量
57
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信