Kazuyoshi Okada, Hiroyuki Michiwaki, Hiroaki Mori, Manabu Tashiro, Tomoko Inoue, Hisato Shima, Koji Ohshima, Jun Minakuchi, Shu Kawashima
{"title":"同一患者使用相同的血液滤过器进行稀释前和稀释后在线血液滤过的去除效果。","authors":"Kazuyoshi Okada, Hiroyuki Michiwaki, Hiroaki Mori, Manabu Tashiro, Tomoko Inoue, Hisato Shima, Koji Ohshima, Jun Minakuchi, Shu Kawashima","doi":"10.1007/s10047-022-01379-4","DOIUrl":null,"url":null,"abstract":"<p><p>Online hemodiafiltration (OHDF) for renal replacement therapy has two modes: pre- (pre-OHDF) and post-dilution OHDF (post-OHDF). To elucidate the precise differences between the two modes, a clinical study was performed using the same polysulfone hemodiafilters in the same patients. Eight patients were treated with ABH<sup>™</sup>-22PA for 6 weeks: 3 weeks of pre-OHDF (with substitution volumes of 24, 36, and 48 L) and 3 weeks of post-OHDF (6, 8, and 10 L). The reduction ratios of urea, uric acid (UA), creatinine (CRE), inorganic phosphorus (iP), beta-2-microglobulin (β<sub>2</sub>-MG), and alpha-1-microglobulin (α<sub>1</sub>-MG) were evaluated. The removal amounts of β<sub>2</sub>-MG, α<sub>1</sub>-MG, and albumin were also evaluated by analyzing the spent dialysis fluids. The types and numbers of adverse events (AEs) and device malfunctions were recorded. The reduction ratios of urea, UA, CRE, iP, and β<sub>2</sub>-MG were comparable among all conditions, while that of α<sub>1</sub>-MG tended to be slightly higher in post-OHDF than in pre-OHDF. The removal amounts of α<sub>1</sub>-MG and albumin in pre-OHDF and post-OHDF were significantly greater with the maximum substitution volume than with the minimum volume. However, the selective removal indices, which were obtained by dividing the amount of α<sub>1</sub>-MG removed by the albumin level, tended to be slightly higher in pre- than in post-OHDF. No device-related AEs or device malfunctions occurred in either mode. No significant differences in inflammatory responses, evaluated by high-sensitivity C-reactive protein and interleukin-6, were observed. This study provides removal performance and safety data regarding the application of ABH-22PA for pre- and post-OHDF.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635926/pdf/","citationCount":"1","resultStr":"{\"title\":\"Removal performance of pre- and post-dilution online hemodiafiltration using identical hemodiafilters in the same patients.\",\"authors\":\"Kazuyoshi Okada, Hiroyuki Michiwaki, Hiroaki Mori, Manabu Tashiro, Tomoko Inoue, Hisato Shima, Koji Ohshima, Jun Minakuchi, Shu Kawashima\",\"doi\":\"10.1007/s10047-022-01379-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Online hemodiafiltration (OHDF) for renal replacement therapy has two modes: pre- (pre-OHDF) and post-dilution OHDF (post-OHDF). To elucidate the precise differences between the two modes, a clinical study was performed using the same polysulfone hemodiafilters in the same patients. Eight patients were treated with ABH<sup>™</sup>-22PA for 6 weeks: 3 weeks of pre-OHDF (with substitution volumes of 24, 36, and 48 L) and 3 weeks of post-OHDF (6, 8, and 10 L). The reduction ratios of urea, uric acid (UA), creatinine (CRE), inorganic phosphorus (iP), beta-2-microglobulin (β<sub>2</sub>-MG), and alpha-1-microglobulin (α<sub>1</sub>-MG) were evaluated. The removal amounts of β<sub>2</sub>-MG, α<sub>1</sub>-MG, and albumin were also evaluated by analyzing the spent dialysis fluids. The types and numbers of adverse events (AEs) and device malfunctions were recorded. The reduction ratios of urea, UA, CRE, iP, and β<sub>2</sub>-MG were comparable among all conditions, while that of α<sub>1</sub>-MG tended to be slightly higher in post-OHDF than in pre-OHDF. The removal amounts of α<sub>1</sub>-MG and albumin in pre-OHDF and post-OHDF were significantly greater with the maximum substitution volume than with the minimum volume. However, the selective removal indices, which were obtained by dividing the amount of α<sub>1</sub>-MG removed by the albumin level, tended to be slightly higher in pre- than in post-OHDF. No device-related AEs or device malfunctions occurred in either mode. No significant differences in inflammatory responses, evaluated by high-sensitivity C-reactive protein and interleukin-6, were observed. This study provides removal performance and safety data regarding the application of ABH-22PA for pre- and post-OHDF.</p>\",\"PeriodicalId\":15177,\"journal\":{\"name\":\"Journal of Artificial Organs\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10635926/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Artificial Organs\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1007/s10047-022-01379-4\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/12/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-022-01379-4","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/12/14 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
Removal performance of pre- and post-dilution online hemodiafiltration using identical hemodiafilters in the same patients.
Online hemodiafiltration (OHDF) for renal replacement therapy has two modes: pre- (pre-OHDF) and post-dilution OHDF (post-OHDF). To elucidate the precise differences between the two modes, a clinical study was performed using the same polysulfone hemodiafilters in the same patients. Eight patients were treated with ABH™-22PA for 6 weeks: 3 weeks of pre-OHDF (with substitution volumes of 24, 36, and 48 L) and 3 weeks of post-OHDF (6, 8, and 10 L). The reduction ratios of urea, uric acid (UA), creatinine (CRE), inorganic phosphorus (iP), beta-2-microglobulin (β2-MG), and alpha-1-microglobulin (α1-MG) were evaluated. The removal amounts of β2-MG, α1-MG, and albumin were also evaluated by analyzing the spent dialysis fluids. The types and numbers of adverse events (AEs) and device malfunctions were recorded. The reduction ratios of urea, UA, CRE, iP, and β2-MG were comparable among all conditions, while that of α1-MG tended to be slightly higher in post-OHDF than in pre-OHDF. The removal amounts of α1-MG and albumin in pre-OHDF and post-OHDF were significantly greater with the maximum substitution volume than with the minimum volume. However, the selective removal indices, which were obtained by dividing the amount of α1-MG removed by the albumin level, tended to be slightly higher in pre- than in post-OHDF. No device-related AEs or device malfunctions occurred in either mode. No significant differences in inflammatory responses, evaluated by high-sensitivity C-reactive protein and interleukin-6, were observed. This study provides removal performance and safety data regarding the application of ABH-22PA for pre- and post-OHDF.
期刊介绍:
The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.