[基于不对称流场-流分馏的天麻多糖分离与表征:立体过渡现象]。

IF 1.2 4区 化学 Q4 CHEMISTRY, ANALYTICAL
Mu Wang, Xi-Rui Zhang, Yu-Wei Dou, Hong Ye, Hai-Yang Dou
{"title":"[基于不对称流场-流分馏的天麻多糖分离与表征:立体过渡现象]。","authors":"Mu Wang,&nbsp;Xi-Rui Zhang,&nbsp;Yu-Wei Dou,&nbsp;Hong Ye,&nbsp;Hai-Yang Dou","doi":"10.3724/SP.J.1123.2022.11020","DOIUrl":null,"url":null,"abstract":"<p><p>Asymmetrical flow field-flow fractionation (AF4), a gentle tool for the separation and characterization of particles and macromolecules, has attracted increased interest in recent years owing to its broad dynamic size range and utilization of \"open channel\" voids in the packing or stationary phase. A steric transition phenomenon in which the sample elution mode change from the normal mode to the steric/hyperlayer mode occurs. Accurate characterization by AF4 requires the absence of steric transition, particularly when the sample has a broad size distribution, because the effect of the combination of different modes is difficult to interpret. In this study, the relative molecular mass (<i>M</i>), radius of gyration (<i>R</i><sub>g</sub>), and conformation of <i>Gastrodia elata</i> polysaccharides (GEPs) were characterized using AF4 coupled with online multi-angle light scattering (MALS) and differential refractive index (dRI) detection (AF4-MALS-dRI). Steric transition was observed during GEP separation by AF4 owing to the broad size distribution of the molecules. This phenomenon would result in the inaccurate characterization of the GEPs in terms of <i>M</i> and <i>R</i><sub>g</sub> because two GEP groups of different sizes may elute together. In this study, the effects of constant and exponentially decaying cross-flow rates, sample mass concentration, and spacer thickness on steric transition were systematically investigated. The results indicated that a high GEP mass concentration (i. e., 0.75 mg/mL) can lead to steric transition. The spacer thickness affected the resolution and retention time of the GEPs and changed the steric transition point (<i>d</i><sub>i</sub>). An exponentially decaying cross-flow rate not only adjusted the <i>d</i><sub>i</sub> of the polydisperse GEP samples but also improved the GEP resolution and shortened the analysis time. The influence of steric transition was solved under the following operating conditions: injected GEP mass concentration=0.5 mg/mL; injection volume=50 μL; spacer thickness=350 μm; detector flow rate=1.0 mL/min; and cross-flow rate exponentially decayed from 0.2 to 0.05 mL/min with a half-life of 2 min. Moreover, the influence of GEP origins and ultrasound treatment time on the <i>M</i> and <i>R</i><sub>g</sub> distributions and conformation of GEPs were investigated under the optimized operating conditions. The results showed that the <i>M</i> and <i>R</i><sub>g</sub> distributions of Yunnan and Sichuan GEPs decreased with increasing ultrasound time. When the ultrasound treatment time was 15 min, the Yunnan GEPs had a loosely hyperbranched chain conformation, whereas the Sichuan GEPs had a spherical conformation. When the ultrasound treatment time was increased to 30 or 60 min, the GEPs from both Yunnan and Sichuan had a hyperbranched chain conformation, indicating that ultrasound treatment resulted in GEP degradation. Under the same extraction conditions, GEPs from Yunnan had larger <i>M</i> and <i>R</i><sub>g</sub> values than those from Sichuan. AF4-MALS-dRI showed good repeatability for the characterization of GEPs under the optimized operating conditions. The relative standard deviations of <i>R</i><sub>g</sub> and <i>M</i> were 0.5% and 1.7%, respectively. The data presented in this study can be used as a starting point for in-depth studies on the structural bioactivity of GEPs.</p>","PeriodicalId":9864,"journal":{"name":"色谱","volume":"41 8","pages":"714-721"},"PeriodicalIF":1.2000,"publicationDate":"2023-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398820/pdf/cjc-41-08-714.pdf","citationCount":"0","resultStr":"{\"title\":\"[Separation and characterization of <i>Gastrodia elata</i> polysaccharides based on asymmetrical flow field-flow fractionation: steric transition phenomenon].\",\"authors\":\"Mu Wang,&nbsp;Xi-Rui Zhang,&nbsp;Yu-Wei Dou,&nbsp;Hong Ye,&nbsp;Hai-Yang Dou\",\"doi\":\"10.3724/SP.J.1123.2022.11020\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Asymmetrical flow field-flow fractionation (AF4), a gentle tool for the separation and characterization of particles and macromolecules, has attracted increased interest in recent years owing to its broad dynamic size range and utilization of \\\"open channel\\\" voids in the packing or stationary phase. A steric transition phenomenon in which the sample elution mode change from the normal mode to the steric/hyperlayer mode occurs. Accurate characterization by AF4 requires the absence of steric transition, particularly when the sample has a broad size distribution, because the effect of the combination of different modes is difficult to interpret. In this study, the relative molecular mass (<i>M</i>), radius of gyration (<i>R</i><sub>g</sub>), and conformation of <i>Gastrodia elata</i> polysaccharides (GEPs) were characterized using AF4 coupled with online multi-angle light scattering (MALS) and differential refractive index (dRI) detection (AF4-MALS-dRI). Steric transition was observed during GEP separation by AF4 owing to the broad size distribution of the molecules. This phenomenon would result in the inaccurate characterization of the GEPs in terms of <i>M</i> and <i>R</i><sub>g</sub> because two GEP groups of different sizes may elute together. In this study, the effects of constant and exponentially decaying cross-flow rates, sample mass concentration, and spacer thickness on steric transition were systematically investigated. The results indicated that a high GEP mass concentration (i. e., 0.75 mg/mL) can lead to steric transition. The spacer thickness affected the resolution and retention time of the GEPs and changed the steric transition point (<i>d</i><sub>i</sub>). An exponentially decaying cross-flow rate not only adjusted the <i>d</i><sub>i</sub> of the polydisperse GEP samples but also improved the GEP resolution and shortened the analysis time. The influence of steric transition was solved under the following operating conditions: injected GEP mass concentration=0.5 mg/mL; injection volume=50 μL; spacer thickness=350 μm; detector flow rate=1.0 mL/min; and cross-flow rate exponentially decayed from 0.2 to 0.05 mL/min with a half-life of 2 min. Moreover, the influence of GEP origins and ultrasound treatment time on the <i>M</i> and <i>R</i><sub>g</sub> distributions and conformation of GEPs were investigated under the optimized operating conditions. The results showed that the <i>M</i> and <i>R</i><sub>g</sub> distributions of Yunnan and Sichuan GEPs decreased with increasing ultrasound time. When the ultrasound treatment time was 15 min, the Yunnan GEPs had a loosely hyperbranched chain conformation, whereas the Sichuan GEPs had a spherical conformation. When the ultrasound treatment time was increased to 30 or 60 min, the GEPs from both Yunnan and Sichuan had a hyperbranched chain conformation, indicating that ultrasound treatment resulted in GEP degradation. Under the same extraction conditions, GEPs from Yunnan had larger <i>M</i> and <i>R</i><sub>g</sub> values than those from Sichuan. AF4-MALS-dRI showed good repeatability for the characterization of GEPs under the optimized operating conditions. The relative standard deviations of <i>R</i><sub>g</sub> and <i>M</i> were 0.5% and 1.7%, respectively. The data presented in this study can be used as a starting point for in-depth studies on the structural bioactivity of GEPs.</p>\",\"PeriodicalId\":9864,\"journal\":{\"name\":\"色谱\",\"volume\":\"41 8\",\"pages\":\"714-721\"},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2023-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10398820/pdf/cjc-41-08-714.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"色谱\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.3724/SP.J.1123.2022.11020\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"色谱","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.3724/SP.J.1123.2022.11020","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

非对称流场-流动分选(AF4)是一种用于分离和表征颗粒和大分子的温和工具,近年来由于其广泛的动态尺寸范围和利用填料或固定相中的“开放通道”空隙而引起了越来越多的兴趣。发生样品洗脱模式从正常模式转变为立体/超层模式的一种立体过渡现象。AF4的准确表征要求没有空间跃迁,特别是当样品具有广泛的尺寸分布时,因为不同模式组合的影响很难解释。本研究利用AF4结合在线多角度光散射(MALS)和差示折射率(dRI)检测(AF4-MALS-dRI)对天麻多糖(GEPs)的相对分子质量(M)、旋转半径(Rg)和构象进行了表征。由于分子的大尺寸分布,AF4在GEP分离过程中观察到立体跃迁。这种现象将导致用M和Rg来描述GEP的不准确特征,因为两个不同大小的GEP组可能会一起洗脱。在本研究中,系统地研究了恒定和指数衰减的横流速率、样品质量浓度和间隔层厚度对立体跃迁的影响。结果表明,较高的GEP质量浓度(即0.75 mg/mL)可导致位位跃迁。间隔层厚度影响gep的分辨率和滞留时间,改变空间过渡点(di)。指数衰减的交叉流率不仅可以调节多分散GEP样品的di,还可以提高GEP的分辨率,缩短分析时间。在以下操作条件下解决了立体跃迁的影响:注射GEP质量浓度=0.5 mg/mL;注射量=50 μL;垫片厚度=350 μm;检测器流速=1.0 mL/min;横流速率从0.2 mL/min呈指数衰减至0.05 mL/min,半衰期为2 min。此外,在优化的操作条件下,研究了GEP来源和超声处理时间对GEP M和Rg分布及构象的影响。结果表明,云南和四川GEPs的M和Rg分布随超声时间的增加而减小。超声处理时间为15 min时,云南GEPs具有松散的超支链构象,而四川GEPs具有球形构象。当超声处理时间增加到30或60 min时,云南和四川的GEP都出现了超支链构象,表明超声处理导致了GEP的降解。在相同提取条件下,云南产GEPs的M和Rg值均大于四川产GEPs。在优化的操作条件下,AF4-MALS-dRI对GEPs的表征具有良好的重复性。Rg和M的相对标准偏差分别为0.5%和1.7%。本研究提供的数据可作为深入研究GEPs结构生物活性的起点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Separation and characterization of Gastrodia elata polysaccharides based on asymmetrical flow field-flow fractionation: steric transition phenomenon].

Asymmetrical flow field-flow fractionation (AF4), a gentle tool for the separation and characterization of particles and macromolecules, has attracted increased interest in recent years owing to its broad dynamic size range and utilization of "open channel" voids in the packing or stationary phase. A steric transition phenomenon in which the sample elution mode change from the normal mode to the steric/hyperlayer mode occurs. Accurate characterization by AF4 requires the absence of steric transition, particularly when the sample has a broad size distribution, because the effect of the combination of different modes is difficult to interpret. In this study, the relative molecular mass (M), radius of gyration (Rg), and conformation of Gastrodia elata polysaccharides (GEPs) were characterized using AF4 coupled with online multi-angle light scattering (MALS) and differential refractive index (dRI) detection (AF4-MALS-dRI). Steric transition was observed during GEP separation by AF4 owing to the broad size distribution of the molecules. This phenomenon would result in the inaccurate characterization of the GEPs in terms of M and Rg because two GEP groups of different sizes may elute together. In this study, the effects of constant and exponentially decaying cross-flow rates, sample mass concentration, and spacer thickness on steric transition were systematically investigated. The results indicated that a high GEP mass concentration (i. e., 0.75 mg/mL) can lead to steric transition. The spacer thickness affected the resolution and retention time of the GEPs and changed the steric transition point (di). An exponentially decaying cross-flow rate not only adjusted the di of the polydisperse GEP samples but also improved the GEP resolution and shortened the analysis time. The influence of steric transition was solved under the following operating conditions: injected GEP mass concentration=0.5 mg/mL; injection volume=50 μL; spacer thickness=350 μm; detector flow rate=1.0 mL/min; and cross-flow rate exponentially decayed from 0.2 to 0.05 mL/min with a half-life of 2 min. Moreover, the influence of GEP origins and ultrasound treatment time on the M and Rg distributions and conformation of GEPs were investigated under the optimized operating conditions. The results showed that the M and Rg distributions of Yunnan and Sichuan GEPs decreased with increasing ultrasound time. When the ultrasound treatment time was 15 min, the Yunnan GEPs had a loosely hyperbranched chain conformation, whereas the Sichuan GEPs had a spherical conformation. When the ultrasound treatment time was increased to 30 or 60 min, the GEPs from both Yunnan and Sichuan had a hyperbranched chain conformation, indicating that ultrasound treatment resulted in GEP degradation. Under the same extraction conditions, GEPs from Yunnan had larger M and Rg values than those from Sichuan. AF4-MALS-dRI showed good repeatability for the characterization of GEPs under the optimized operating conditions. The relative standard deviations of Rg and M were 0.5% and 1.7%, respectively. The data presented in this study can be used as a starting point for in-depth studies on the structural bioactivity of GEPs.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
色谱
色谱 CHEMISTRY, ANALYTICAL-
CiteScore
1.30
自引率
42.90%
发文量
7198
期刊介绍: "Chinese Journal of Chromatography" mainly reports the basic research results of chromatography, important application results of chromatography and its interdisciplinary subjects and their progress, including the application of new methods, new technologies, and new instruments in various fields, the research and development of chromatography instruments and components, instrument analysis teaching research, etc. It is suitable for researchers engaged in chromatography basic and application technology research in scientific research institutes, master and doctoral students in chromatography and related disciplines, grassroots researchers in the field of analysis and testing, and relevant personnel in chromatography instrument development and operation units. The journal has columns such as special planning, focus, perspective, research express, research paper, monograph and review, micro review, technology and application, and teaching research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信