Sasa Kou, Yaru Ren, Xinyu Zhuang, Yingjie Chen, Xiaofeng Zhang
{"title":"佩戴Paragon CRT与欧几里德角膜塑形镜后治疗区相关因素的研究。","authors":"Sasa Kou, Yaru Ren, Xinyu Zhuang, Yingjie Chen, Xiaofeng Zhang","doi":"10.1097/ICL.0000000000001035","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.</p><p><strong>Methods: </strong>The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.</p><p><strong>Results: </strong>There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) ( P <0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups ( P <0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) ( P =0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups ( P <0.05).</p><p><strong>Conclusion: </strong>For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.</p>","PeriodicalId":50457,"journal":{"name":"Eye & Contact Lens-Science and Clinical Practice","volume":" ","pages":"521-527"},"PeriodicalIF":2.0000,"publicationDate":"2023-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659246/pdf/","citationCount":"0","resultStr":"{\"title\":\"Study on Related Factors of the Treatment Zone After Wearing Paragon CRT and Euclid Orthokeratology Lenses.\",\"authors\":\"Sasa Kou, Yaru Ren, Xinyu Zhuang, Yingjie Chen, Xiaofeng Zhang\",\"doi\":\"10.1097/ICL.0000000000001035\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.</p><p><strong>Methods: </strong>The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.</p><p><strong>Results: </strong>There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) ( P <0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups ( P <0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) ( P =0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups ( P <0.05).</p><p><strong>Conclusion: </strong>For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.</p>\",\"PeriodicalId\":50457,\"journal\":{\"name\":\"Eye & Contact Lens-Science and Clinical Practice\",\"volume\":\" \",\"pages\":\"521-527\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10659246/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eye & Contact Lens-Science and Clinical Practice\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/ICL.0000000000001035\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/14 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eye & Contact Lens-Science and Clinical Practice","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ICL.0000000000001035","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/14 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Study on Related Factors of the Treatment Zone After Wearing Paragon CRT and Euclid Orthokeratology Lenses.
Objective: To explore the influence factors of the treatment zone diameter (TZD) and its relationship with axial length growth (ALG) after wearing Paragon CRT and Euclid orthokeratology lenses.
Methods: The right eye data of myopic patients wearing Paragon CRT and Euclid orthokeratology in the ophthalmology department of The First Affiliated Hospital of Soochow University were retrospectively reviewed from April 2019 to October 2022. The TZD and ALG were compared between the Paragon CRT and Euclid groups. The correlation factors of TZD after wearing lens for 1 month and the relationship between the overlapping treatment zone-to-pupil area ratio and the ALG after wearing lens for 1 year were analyzed between the two groups.
Results: There were 160 patients (160 eyes) in the Paragon CRT group and 155 patients (155 eyes) in the Euclid group. After wearing lens for 1 month, the TZD in the Paragon CRT group (3.72±0.37 mm) was larger than that in the Euclid group (3.26±0.37 mm) ( P <0.001). The stepwise multivariate linear regression analysis showed that the eccentricity at the flattest meridians (Em) and the central corneal thickness were correlated with the TZD in both groups ( P <0.05). After wearing lens for 1 year, the ALG in the Paragon CRT group (0.32±0.20 mm) was larger than that in the Euclid group (0.25±0.20 mm) ( P =0.001). The stepwise multivariate linear regression analysis showed that the initial wearing age and the overlapping treatment zone area-to-pupil area ratio were correlated with the ALG in both groups ( P <0.05).
Conclusion: For both the Paragon CRT and Euclid orthokeratology, the wearers with thicker central corneal thickness and smaller Em usually had a smaller TZD. In both groups, the overlapping treatment zone area-to-pupil area ratio was correlated with the ALG.
期刊介绍:
Eye & Contact Lens: Science and Clinical Practice is the official journal of the Contact Lens Association of Ophthalmologists (CLAO), an international educational association for anterior segment research and clinical practice of interest to ophthalmologists, optometrists, and other vision care providers and researchers. Focusing especially on contact lenses, it also covers dry eye disease, MGD, infections, toxicity of drops and contact lens care solutions, topography, cornea surgery and post-operative care, optics, refractive surgery and corneal stability (eg, UV cross-linking). Peer-reviewed and published six times annually, it is a highly respected scientific journal in its field.