心脏外科医生手术时应考虑到瓣膜的位置。

IF 2.2 4区 医学 Q2 SURGERY
Tsu-Hsien Wang, Yi-No Kang, Wan-Ying Lin, Kuan-Yu Chi
{"title":"心脏外科医生手术时应考虑到瓣膜的位置。","authors":"Tsu-Hsien Wang, Yi-No Kang, Wan-Ying Lin, Kuan-Yu Chi","doi":"10.1503/cjs.010122-l","DOIUrl":null,"url":null,"abstract":"We read the art ic le entit led “Mechanical versus bioprosthetic valves in chronic dialysis: a systematic review and meta-analysis” by Kim and colleagues,1 with great interest. The authors attempted to address limitations of previous meta-analyses by expanding the searching strategy and exhausting more databases without placing any language restriction. They concluded that the significant benefit of lower all-cause mortality with the use of mechanical prosthesis (MP) was at the expense of higher risks of bleeding and stroke. We appreciated the authors’ efforts and contribution, and concur with the authors that most studies were subject to high risk of unmeasured confounding bias owing to unreported demographics, which lowers the quality of evidence considerably. However, we believe that the prosthetic position upon which cardiac surgeons operate is a significant contributor to not only conceptual, but also statistical heterogeneity. Besides, compared with relative risk (RR) that Kim and colleagues selected for the analysis of all-cause mortality, hazard ratio (HR) is supposed to be a more appropriate statistic, as it incorporates time into the consideration. Thus, we followed Kim and colleagues’ inclusion criteria and reconducted the meta-analysis with the introduction of a subgroup analysis based on valve position. There are 8 studies2–9 providing comparative long-term survival outcome for aortic valve replacement (AVR) between MP and bioprosthesis (BP) in dialysis patients. We showed that dialysis patients using MP for AVR was associated with significantly lower longterm all-cause mortality than those using BP (HR 0.65, 95 % confidence interval [CI] 0.51–0.83, I2 = 0 %) (Figure 1). On the other hand, the long-term overall survival was comparable between MP and BP (HR 0.91, 95 % CI 0.77–1.07, I2 = 0 %) (Figure 1) in mixed cohorts of AVR and mitral valve replacement (MVR). Regarding the bleeding events, although the use of MP was associated with a considerably higher risk in studies including mixed cohorts of AVR and MVR (incidence rate ratio [IRR] 2.37, 95% CI 1.34–4.22, I2 = 41%), we found that there was no significant difference in bleeding events between MP and BP in patients undergoing AVR (IRR 1.18, 95% CI 0.28–4.85, I2 = 0 %) (Figure 1). One plausible explanation for similar bleeding risk between MP and BP in dialysis patients undergoing AVR may reside in the lower target of international normalized ratio (INR), usual ly less than 2.5, used in this popu lation, as compared with the target of 3.0 used in MVR.28 In fact, it LETTERS • LETTRES","PeriodicalId":9573,"journal":{"name":"Canadian Journal of Surgery","volume":"66 5","pages":"E472-E473"},"PeriodicalIF":2.2000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/91/d4/066E472.PMC10495162.pdf","citationCount":"0","resultStr":"{\"title\":\"Valve positions upon which cardiac surgeons operate should be taken into consideration.\",\"authors\":\"Tsu-Hsien Wang, Yi-No Kang, Wan-Ying Lin, Kuan-Yu Chi\",\"doi\":\"10.1503/cjs.010122-l\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"We read the art ic le entit led “Mechanical versus bioprosthetic valves in chronic dialysis: a systematic review and meta-analysis” by Kim and colleagues,1 with great interest. The authors attempted to address limitations of previous meta-analyses by expanding the searching strategy and exhausting more databases without placing any language restriction. They concluded that the significant benefit of lower all-cause mortality with the use of mechanical prosthesis (MP) was at the expense of higher risks of bleeding and stroke. We appreciated the authors’ efforts and contribution, and concur with the authors that most studies were subject to high risk of unmeasured confounding bias owing to unreported demographics, which lowers the quality of evidence considerably. However, we believe that the prosthetic position upon which cardiac surgeons operate is a significant contributor to not only conceptual, but also statistical heterogeneity. Besides, compared with relative risk (RR) that Kim and colleagues selected for the analysis of all-cause mortality, hazard ratio (HR) is supposed to be a more appropriate statistic, as it incorporates time into the consideration. Thus, we followed Kim and colleagues’ inclusion criteria and reconducted the meta-analysis with the introduction of a subgroup analysis based on valve position. There are 8 studies2–9 providing comparative long-term survival outcome for aortic valve replacement (AVR) between MP and bioprosthesis (BP) in dialysis patients. We showed that dialysis patients using MP for AVR was associated with significantly lower longterm all-cause mortality than those using BP (HR 0.65, 95 % confidence interval [CI] 0.51–0.83, I2 = 0 %) (Figure 1). On the other hand, the long-term overall survival was comparable between MP and BP (HR 0.91, 95 % CI 0.77–1.07, I2 = 0 %) (Figure 1) in mixed cohorts of AVR and mitral valve replacement (MVR). Regarding the bleeding events, although the use of MP was associated with a considerably higher risk in studies including mixed cohorts of AVR and MVR (incidence rate ratio [IRR] 2.37, 95% CI 1.34–4.22, I2 = 41%), we found that there was no significant difference in bleeding events between MP and BP in patients undergoing AVR (IRR 1.18, 95% CI 0.28–4.85, I2 = 0 %) (Figure 1). One plausible explanation for similar bleeding risk between MP and BP in dialysis patients undergoing AVR may reside in the lower target of international normalized ratio (INR), usual ly less than 2.5, used in this popu lation, as compared with the target of 3.0 used in MVR.28 In fact, it LETTERS • LETTRES\",\"PeriodicalId\":9573,\"journal\":{\"name\":\"Canadian Journal of Surgery\",\"volume\":\"66 5\",\"pages\":\"E472-E473\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/91/d4/066E472.PMC10495162.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Canadian Journal of Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1503/cjs.010122-l\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Canadian Journal of Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1503/cjs.010122-l","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"SURGERY","Score":null,"Total":0}
引用次数: 0

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。

Valve positions upon which cardiac surgeons operate should be taken into consideration.

Valve positions upon which cardiac surgeons operate should be taken into consideration.
We read the art ic le entit led “Mechanical versus bioprosthetic valves in chronic dialysis: a systematic review and meta-analysis” by Kim and colleagues,1 with great interest. The authors attempted to address limitations of previous meta-analyses by expanding the searching strategy and exhausting more databases without placing any language restriction. They concluded that the significant benefit of lower all-cause mortality with the use of mechanical prosthesis (MP) was at the expense of higher risks of bleeding and stroke. We appreciated the authors’ efforts and contribution, and concur with the authors that most studies were subject to high risk of unmeasured confounding bias owing to unreported demographics, which lowers the quality of evidence considerably. However, we believe that the prosthetic position upon which cardiac surgeons operate is a significant contributor to not only conceptual, but also statistical heterogeneity. Besides, compared with relative risk (RR) that Kim and colleagues selected for the analysis of all-cause mortality, hazard ratio (HR) is supposed to be a more appropriate statistic, as it incorporates time into the consideration. Thus, we followed Kim and colleagues’ inclusion criteria and reconducted the meta-analysis with the introduction of a subgroup analysis based on valve position. There are 8 studies2–9 providing comparative long-term survival outcome for aortic valve replacement (AVR) between MP and bioprosthesis (BP) in dialysis patients. We showed that dialysis patients using MP for AVR was associated with significantly lower longterm all-cause mortality than those using BP (HR 0.65, 95 % confidence interval [CI] 0.51–0.83, I2 = 0 %) (Figure 1). On the other hand, the long-term overall survival was comparable between MP and BP (HR 0.91, 95 % CI 0.77–1.07, I2 = 0 %) (Figure 1) in mixed cohorts of AVR and mitral valve replacement (MVR). Regarding the bleeding events, although the use of MP was associated with a considerably higher risk in studies including mixed cohorts of AVR and MVR (incidence rate ratio [IRR] 2.37, 95% CI 1.34–4.22, I2 = 41%), we found that there was no significant difference in bleeding events between MP and BP in patients undergoing AVR (IRR 1.18, 95% CI 0.28–4.85, I2 = 0 %) (Figure 1). One plausible explanation for similar bleeding risk between MP and BP in dialysis patients undergoing AVR may reside in the lower target of international normalized ratio (INR), usual ly less than 2.5, used in this popu lation, as compared with the target of 3.0 used in MVR.28 In fact, it LETTERS • LETTRES
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
3.00
自引率
8.00%
发文量
120
审稿时长
6-12 weeks
期刊介绍: The mission of CJS is to contribute to the meaningful continuing medical education of Canadian surgical specialists, and to provide surgeons with an effective vehicle for the dissemination of observations in the areas of clinical and basic science research.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信