{"title":"动态植入手术中基准标记数目和配置对配准误差的影响。","authors":"Yihan Shen, Baoxin Tao, Yuanyuan Sun, Wei Huang, Feng Wang, Yiqun Wu","doi":"10.11607/jomi.10134","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To verify the effect of fiducial marker number and configuration on target registration error (TRE) for dynamic computer-aided zygomatic implant surgery. <b>Material and Methods:</b> All patients who underwent zygomatic implant surgery with navigation from January 2018 to December 2021 were enrolled. For each patient, 6 to 8 miniscrews were placed intraorally as fiducial markers before the surgery. After the registration procedure, the TRE, which represents the distance between the target of the image space and the real position of the fiducial markers, was calculated. SPSS (22.0) was used for statistical analysis. <b>Results:</b> A total of 325 titanium miniscrews were placed in 47 patients who underwent zygomatic implant placement by navigation. The lowest TRE was 0.2 mm, compared to the highest TRE of 1.9 mm. There was no significant difference in the mean TRE value among the different titanium miniscrew groups (<i>P</i> = .07). A total of 8 miniscrews in 7 patients were lost in the maxillary tuberosity area prior to and during navigation surgery, which resulted in an irregular polygonal distribution of fiducial markers. However, there was no statistically significant difference in TRE between a polygonal distribution (0.62 ± 0.35 mm) and an irregular polygonal distribution (0.68 ± 0.33 mm) (<i>P</i> = .35). <b>Conclusion:</b> A scattered, polygonal distribution with of a minimum of five fiducial markers in an edentulous maxilla could achieve acceptable TRE values in registration. It seems that the registration error was not influenced by the absence of one corner in a polygon distribution.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The Effect of Fiducial Marker Number and Configuration on Registration Error in Dynamic Implant Surgery.\",\"authors\":\"Yihan Shen, Baoxin Tao, Yuanyuan Sun, Wei Huang, Feng Wang, Yiqun Wu\",\"doi\":\"10.11607/jomi.10134\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective:</b> To verify the effect of fiducial marker number and configuration on target registration error (TRE) for dynamic computer-aided zygomatic implant surgery. <b>Material and Methods:</b> All patients who underwent zygomatic implant surgery with navigation from January 2018 to December 2021 were enrolled. For each patient, 6 to 8 miniscrews were placed intraorally as fiducial markers before the surgery. After the registration procedure, the TRE, which represents the distance between the target of the image space and the real position of the fiducial markers, was calculated. SPSS (22.0) was used for statistical analysis. <b>Results:</b> A total of 325 titanium miniscrews were placed in 47 patients who underwent zygomatic implant placement by navigation. The lowest TRE was 0.2 mm, compared to the highest TRE of 1.9 mm. There was no significant difference in the mean TRE value among the different titanium miniscrew groups (<i>P</i> = .07). A total of 8 miniscrews in 7 patients were lost in the maxillary tuberosity area prior to and during navigation surgery, which resulted in an irregular polygonal distribution of fiducial markers. However, there was no statistically significant difference in TRE between a polygonal distribution (0.62 ± 0.35 mm) and an irregular polygonal distribution (0.68 ± 0.33 mm) (<i>P</i> = .35). <b>Conclusion:</b> A scattered, polygonal distribution with of a minimum of five fiducial markers in an edentulous maxilla could achieve acceptable TRE values in registration. It seems that the registration error was not influenced by the absence of one corner in a polygon distribution.</p>\",\"PeriodicalId\":1,\"journal\":{\"name\":\"Accounts of Chemical Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":16.4000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Accounts of Chemical Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.11607/jomi.10134\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.11607/jomi.10134","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
The Effect of Fiducial Marker Number and Configuration on Registration Error in Dynamic Implant Surgery.
Objective: To verify the effect of fiducial marker number and configuration on target registration error (TRE) for dynamic computer-aided zygomatic implant surgery. Material and Methods: All patients who underwent zygomatic implant surgery with navigation from January 2018 to December 2021 were enrolled. For each patient, 6 to 8 miniscrews were placed intraorally as fiducial markers before the surgery. After the registration procedure, the TRE, which represents the distance between the target of the image space and the real position of the fiducial markers, was calculated. SPSS (22.0) was used for statistical analysis. Results: A total of 325 titanium miniscrews were placed in 47 patients who underwent zygomatic implant placement by navigation. The lowest TRE was 0.2 mm, compared to the highest TRE of 1.9 mm. There was no significant difference in the mean TRE value among the different titanium miniscrew groups (P = .07). A total of 8 miniscrews in 7 patients were lost in the maxillary tuberosity area prior to and during navigation surgery, which resulted in an irregular polygonal distribution of fiducial markers. However, there was no statistically significant difference in TRE between a polygonal distribution (0.62 ± 0.35 mm) and an irregular polygonal distribution (0.68 ± 0.33 mm) (P = .35). Conclusion: A scattered, polygonal distribution with of a minimum of five fiducial markers in an edentulous maxilla could achieve acceptable TRE values in registration. It seems that the registration error was not influenced by the absence of one corner in a polygon distribution.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.