循环miR-140-3p、miR-130a-3p和miR-320b作为急性缺血性卒中诊断生物标志物的表达水平

IF 2.7 4区 医学 Q3 MEDICINE, RESEARCH & EXPERIMENTAL
Hong-Yan Ju, Shan-Shan Tang, Bang-Jing Li, Xi Luo, Qi Li
{"title":"循环miR-140-3p、miR-130a-3p和miR-320b作为急性缺血性卒中诊断生物标志物的表达水平","authors":"Hong-Yan Ju,&nbsp;Shan-Shan Tang,&nbsp;Bang-Jing Li,&nbsp;Xi Luo,&nbsp;Qi Li","doi":"10.1002/kjm2.12721","DOIUrl":null,"url":null,"abstract":"<p><p>Plasma miRNAs can characterize several diseases, including acute ischemic stroke (AIS), which is noninvasive and currently affordable in most laboratories worldwide. We aimed to demonstrate plasma miR-140-3p, miR-130a-3p, and miR-320b as diagnostic biomarkers in AIS.GSE110993 and GSE86291 datasets were analyzed to obtain plasma differentially expressed miRNAs between AIS and healthy control subjects (HCs). We further applied RT-qPCR for the validation in 85 AIS patients and 85 HCs. Receiver operating characteristic (ROC) curve were conducted to evaluate their diagnostic utility in AIS. Correlation was analyzed between DEmiRNAs and clinical and laboratory parameters, as well as inflammatory markers. The plasma levels of miR-140-3p, miR-130a-3p, and miR-320b were found to be consistently altered in both GSE110993 and GSE86291 datasets. In comparison to HCs, AIS patients at admission exhibited lower levels of miR-140-3p and miR-320b and higher level of miR-130a-3p in their plasma. The ROC analysis revealed that plasma miR-140-3p, miR-130a-3p, and miR-320b had area under the curve values of 0.790, 0.831, and 0.907, respectively. When combined, these miRNAs showed superior discriminatory power with a sensitivity of 91.76% and specificity of 95.29%. Plasma miR-140-3p and miR-320b negatively correlated glucose levels and inflammatory markers (IL-6, MMP-2, MMP-9, and VEGF) in AIS patients. Conversely, plasma miR-130a-3p levels were positively associated with glucose levels and these markers. Plasma miR-140-3p, miR-130a-3p, and miR-320b levels varied significantly among AIS patients with different NIHSS scores. Plasma miR-140-3p, miR-130a-3p, and miR-320b had high diagnostic value in AIS patients, which were correlated with inflammation and severity in stroke.</p>","PeriodicalId":49946,"journal":{"name":"Kaohsiung Journal of Medical Sciences","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The expression levels of circulating miR-140-3p, miR-130a-3p, and miR-320b as diagnostic biomarkers in acute ischemic stroke.\",\"authors\":\"Hong-Yan Ju,&nbsp;Shan-Shan Tang,&nbsp;Bang-Jing Li,&nbsp;Xi Luo,&nbsp;Qi Li\",\"doi\":\"10.1002/kjm2.12721\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Plasma miRNAs can characterize several diseases, including acute ischemic stroke (AIS), which is noninvasive and currently affordable in most laboratories worldwide. We aimed to demonstrate plasma miR-140-3p, miR-130a-3p, and miR-320b as diagnostic biomarkers in AIS.GSE110993 and GSE86291 datasets were analyzed to obtain plasma differentially expressed miRNAs between AIS and healthy control subjects (HCs). We further applied RT-qPCR for the validation in 85 AIS patients and 85 HCs. Receiver operating characteristic (ROC) curve were conducted to evaluate their diagnostic utility in AIS. Correlation was analyzed between DEmiRNAs and clinical and laboratory parameters, as well as inflammatory markers. The plasma levels of miR-140-3p, miR-130a-3p, and miR-320b were found to be consistently altered in both GSE110993 and GSE86291 datasets. In comparison to HCs, AIS patients at admission exhibited lower levels of miR-140-3p and miR-320b and higher level of miR-130a-3p in their plasma. The ROC analysis revealed that plasma miR-140-3p, miR-130a-3p, and miR-320b had area under the curve values of 0.790, 0.831, and 0.907, respectively. When combined, these miRNAs showed superior discriminatory power with a sensitivity of 91.76% and specificity of 95.29%. Plasma miR-140-3p and miR-320b negatively correlated glucose levels and inflammatory markers (IL-6, MMP-2, MMP-9, and VEGF) in AIS patients. Conversely, plasma miR-130a-3p levels were positively associated with glucose levels and these markers. Plasma miR-140-3p, miR-130a-3p, and miR-320b levels varied significantly among AIS patients with different NIHSS scores. Plasma miR-140-3p, miR-130a-3p, and miR-320b had high diagnostic value in AIS patients, which were correlated with inflammation and severity in stroke.</p>\",\"PeriodicalId\":49946,\"journal\":{\"name\":\"Kaohsiung Journal of Medical Sciences\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Kaohsiung Journal of Medical Sciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1002/kjm2.12721\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Kaohsiung Journal of Medical Sciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1002/kjm2.12721","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

血浆mirna可以表征多种疾病,包括急性缺血性中风(AIS),这是无创的,目前世界上大多数实验室都负担得起。我们旨在证明血浆miR-140-3p、miR-130a-3p和miR-320b是AIS的诊断生物标志物。分析GSE110993和GSE86291数据集,获得AIS与健康对照者(hc)血浆差异表达的mirna。我们进一步应用RT-qPCR对85名AIS患者和85名hcc患者进行验证。采用受试者工作特征(ROC)曲线评价其对AIS的诊断价值。分析DEmiRNAs与临床和实验室参数以及炎症标志物之间的相关性。在GSE110993和GSE86291数据集中发现miR-140-3p、miR-130a-3p和miR-320b的血浆水平一致改变。与hcc相比,入院时AIS患者血浆中miR-140-3p和miR-320b水平较低,miR-130a-3p水平较高。ROC分析显示血浆miR-140-3p、miR-130a-3p、miR-320b曲线下面积分别为0.790、0.831、0.907。当组合时,这些mirna表现出优异的区分能力,灵敏度为91.76%,特异性为95.29%。AIS患者血浆miR-140-3p和miR-320b与血糖水平和炎症标志物(IL-6、MMP-2、MMP-9和VEGF)负相关。相反,血浆miR-130a-3p水平与血糖水平和这些标志物呈正相关。不同NIHSS评分的AIS患者血浆miR-140-3p、miR-130a-3p和miR-320b水平差异显著。血浆miR-140-3p、miR-130a-3p、miR-320b在AIS患者中具有较高的诊断价值,与炎症及卒中严重程度相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The expression levels of circulating miR-140-3p, miR-130a-3p, and miR-320b as diagnostic biomarkers in acute ischemic stroke.

Plasma miRNAs can characterize several diseases, including acute ischemic stroke (AIS), which is noninvasive and currently affordable in most laboratories worldwide. We aimed to demonstrate plasma miR-140-3p, miR-130a-3p, and miR-320b as diagnostic biomarkers in AIS.GSE110993 and GSE86291 datasets were analyzed to obtain plasma differentially expressed miRNAs between AIS and healthy control subjects (HCs). We further applied RT-qPCR for the validation in 85 AIS patients and 85 HCs. Receiver operating characteristic (ROC) curve were conducted to evaluate their diagnostic utility in AIS. Correlation was analyzed between DEmiRNAs and clinical and laboratory parameters, as well as inflammatory markers. The plasma levels of miR-140-3p, miR-130a-3p, and miR-320b were found to be consistently altered in both GSE110993 and GSE86291 datasets. In comparison to HCs, AIS patients at admission exhibited lower levels of miR-140-3p and miR-320b and higher level of miR-130a-3p in their plasma. The ROC analysis revealed that plasma miR-140-3p, miR-130a-3p, and miR-320b had area under the curve values of 0.790, 0.831, and 0.907, respectively. When combined, these miRNAs showed superior discriminatory power with a sensitivity of 91.76% and specificity of 95.29%. Plasma miR-140-3p and miR-320b negatively correlated glucose levels and inflammatory markers (IL-6, MMP-2, MMP-9, and VEGF) in AIS patients. Conversely, plasma miR-130a-3p levels were positively associated with glucose levels and these markers. Plasma miR-140-3p, miR-130a-3p, and miR-320b levels varied significantly among AIS patients with different NIHSS scores. Plasma miR-140-3p, miR-130a-3p, and miR-320b had high diagnostic value in AIS patients, which were correlated with inflammation and severity in stroke.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Kaohsiung Journal of Medical Sciences
Kaohsiung Journal of Medical Sciences 医学-医学:研究与实验
CiteScore
5.60
自引率
3.00%
发文量
139
审稿时长
4-8 weeks
期刊介绍: Kaohsiung Journal of Medical Sciences (KJMS), is the official peer-reviewed open access publication of Kaohsiung Medical University, Taiwan. The journal was launched in 1985 to promote clinical and scientific research in the medical sciences in Taiwan, and to disseminate this research to the international community. It is published monthly by Wiley. KJMS aims to publish original research and review papers in all fields of medicine and related disciplines that are of topical interest to the medical profession. Authors are welcome to submit Perspectives, reviews, original articles, short communications, Correspondence and letters to the editor for consideration.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信