电感耦合等离子串联质谱法快速测定人尿中钛

Miao Zhang, Zhifei Zhao, Liang Ding
{"title":"电感耦合等离子串联质谱法快速测定人尿中钛","authors":"Miao Zhang,&nbsp;Zhifei Zhao,&nbsp;Liang Ding","doi":"10.19813/j.cnki.weishengyanjiu.2023.04.014","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To establish an inductively coupled plasma-tandem mass spectrometry(ICP-MS/MS) method to determinate the titanium(Ti) in human urine samples rapidly.</p><p><strong>Methods: </strong>By comparing different gas mode, ~(47)Ti was selected as the analysis element. Injecting NH_3 to the collision/reaction cell, swept by mass spectrum to determine the optimal mass spectrum conditions with the mass number of Q1=47, Q2=149(Ti ammonia hexamer). The mass spectrometry conditions of internal standard elements, integration time, reaction gas flow rate and data processing method and so on were optimized.</p><p><strong>Results: </strong>Ti had a good linear between 0.1-5.00 μg/L under the optimal analytical conditions. The detection limit was 0.1 μg/L. The RSDs of intra-day and inter-day were less than 10%, and the average recoveries were 93.7%-112.2%. The result of Seronorm Trace Elements Urine L-2 met the acceptable range.</p><p><strong>Conclusion: </strong>The method is rapid, simple, accuracy, and suitable for the rapid analysis of titanium in human urine.</p>","PeriodicalId":23789,"journal":{"name":"Wei sheng yan jiu = Journal of hygiene research","volume":"52 4","pages":"604-610"},"PeriodicalIF":0.0000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Rapid determination of titanium in human urine by inductively coupled plasma-tandem mass spectrometry].\",\"authors\":\"Miao Zhang,&nbsp;Zhifei Zhao,&nbsp;Liang Ding\",\"doi\":\"10.19813/j.cnki.weishengyanjiu.2023.04.014\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To establish an inductively coupled plasma-tandem mass spectrometry(ICP-MS/MS) method to determinate the titanium(Ti) in human urine samples rapidly.</p><p><strong>Methods: </strong>By comparing different gas mode, ~(47)Ti was selected as the analysis element. Injecting NH_3 to the collision/reaction cell, swept by mass spectrum to determine the optimal mass spectrum conditions with the mass number of Q1=47, Q2=149(Ti ammonia hexamer). The mass spectrometry conditions of internal standard elements, integration time, reaction gas flow rate and data processing method and so on were optimized.</p><p><strong>Results: </strong>Ti had a good linear between 0.1-5.00 μg/L under the optimal analytical conditions. The detection limit was 0.1 μg/L. The RSDs of intra-day and inter-day were less than 10%, and the average recoveries were 93.7%-112.2%. The result of Seronorm Trace Elements Urine L-2 met the acceptable range.</p><p><strong>Conclusion: </strong>The method is rapid, simple, accuracy, and suitable for the rapid analysis of titanium in human urine.</p>\",\"PeriodicalId\":23789,\"journal\":{\"name\":\"Wei sheng yan jiu = Journal of hygiene research\",\"volume\":\"52 4\",\"pages\":\"604-610\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wei sheng yan jiu = Journal of hygiene research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.19813/j.cnki.weishengyanjiu.2023.04.014\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wei sheng yan jiu = Journal of hygiene research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.19813/j.cnki.weishengyanjiu.2023.04.014","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:建立电感耦合等离子体串联质谱(ICP-MS/MS)快速测定人体尿液中钛(Ti)的方法。方法:通过对不同气相的比较,选择~(47)Ti作为分析元素。将NH_3注入碰撞/反应池,通过质谱扫描确定最佳质谱条件,质量数Q1=47, Q2=149(Ti -氨六聚体)。对内标元素的质谱条件、积分时间、反应气流量、数据处理方法等进行了优化。结果:在最佳分析条件下,Ti在0.1 ~ 5.00 μg/L范围内呈良好的线性关系。检出限为0.1 μg/L。日内、日间的rsd < 10%,平均加样回收率为93.7% ~ 112.2%。血清微量元素尿L-2检测结果符合可接受范围。结论:该方法快速、简便、准确,适用于人尿中钛的快速分析。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Rapid determination of titanium in human urine by inductively coupled plasma-tandem mass spectrometry].

Objective: To establish an inductively coupled plasma-tandem mass spectrometry(ICP-MS/MS) method to determinate the titanium(Ti) in human urine samples rapidly.

Methods: By comparing different gas mode, ~(47)Ti was selected as the analysis element. Injecting NH_3 to the collision/reaction cell, swept by mass spectrum to determine the optimal mass spectrum conditions with the mass number of Q1=47, Q2=149(Ti ammonia hexamer). The mass spectrometry conditions of internal standard elements, integration time, reaction gas flow rate and data processing method and so on were optimized.

Results: Ti had a good linear between 0.1-5.00 μg/L under the optimal analytical conditions. The detection limit was 0.1 μg/L. The RSDs of intra-day and inter-day were less than 10%, and the average recoveries were 93.7%-112.2%. The result of Seronorm Trace Elements Urine L-2 met the acceptable range.

Conclusion: The method is rapid, simple, accuracy, and suitable for the rapid analysis of titanium in human urine.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信