[儿童颅骨减压术后自体骨植入重建手术]。

Q4 Medicine
Zh B Semenova, A I Salimon, A M Korsunsky, A V Melnikov, Yu A Sadykova, A V Marshintsev, E S Statnik, V I Lukyanov
{"title":"[儿童颅骨减压术后自体骨植入重建手术]。","authors":"Zh B Semenova, A I Salimon, A M Korsunsky, A V Melnikov, Yu A Sadykova, A V Marshintsev, E S Statnik, V I Lukyanov","doi":"10.17116/neiro20238704158","DOIUrl":null,"url":null,"abstract":"<p><p>The concept of post-traumatic skull defect closure is based on restoration of anatomical relationships for the maximum possible recovery of brain function, i.e. it is considered as a stage of surgical rehabilitation. The choice of implants in pediatric patients is limited. In this regard, the «gold standard» is still autologous bone implant.</p><p><strong>Material and methods: </strong>We propose a method for storage and sterilization of autologous bone implant. The last one implies keeping at a temperature of -80 ˚C with sterilization in a vacuum chamber filled with hydrogen peroxide vapors of biocidal plasma medium. Sterilization is provided by 45-minute cycle immediately before surgery. We report skull defect closure using autologous bone implants in 79 patients. Evaluation of effectiveness of storage and sterilization of autologous bone implant included analysis of mechanical properties of bone after sterilization, intra-operative microbiological monitoring, incidence of infections in early postoperative period, follow-up with assessment of resorption.</p><p><strong>Results: </strong>Early infectious complications occurred in 2 patients (2.5%). Complete resorption with redo surgery occurred in 6 (10.1%) cases. Sterilization in low-temperature plasma of hydrogen peroxide changes mechanical properties of the bone, increases durability under compressive stresses and decreases durability under tensile conditions. This does not affect functional tasks of autologous bone. The proposed method of storage and sterilization is accompanied by low risk of infections and resorption. Storage of autologous bone implant at a temperature of -80 ˚C with subsequent sterilization in low-temperature plasma of hydrogen peroxide can be considered as a safe and effective method for skull defect closure in children after decompressive surgery.</p>","PeriodicalId":24032,"journal":{"name":"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Autologous bone implant for reconstructive surgery after decompressive craniectomy in children].\",\"authors\":\"Zh B Semenova, A I Salimon, A M Korsunsky, A V Melnikov, Yu A Sadykova, A V Marshintsev, E S Statnik, V I Lukyanov\",\"doi\":\"10.17116/neiro20238704158\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The concept of post-traumatic skull defect closure is based on restoration of anatomical relationships for the maximum possible recovery of brain function, i.e. it is considered as a stage of surgical rehabilitation. The choice of implants in pediatric patients is limited. In this regard, the «gold standard» is still autologous bone implant.</p><p><strong>Material and methods: </strong>We propose a method for storage and sterilization of autologous bone implant. The last one implies keeping at a temperature of -80 ˚C with sterilization in a vacuum chamber filled with hydrogen peroxide vapors of biocidal plasma medium. Sterilization is provided by 45-minute cycle immediately before surgery. We report skull defect closure using autologous bone implants in 79 patients. Evaluation of effectiveness of storage and sterilization of autologous bone implant included analysis of mechanical properties of bone after sterilization, intra-operative microbiological monitoring, incidence of infections in early postoperative period, follow-up with assessment of resorption.</p><p><strong>Results: </strong>Early infectious complications occurred in 2 patients (2.5%). Complete resorption with redo surgery occurred in 6 (10.1%) cases. Sterilization in low-temperature plasma of hydrogen peroxide changes mechanical properties of the bone, increases durability under compressive stresses and decreases durability under tensile conditions. This does not affect functional tasks of autologous bone. The proposed method of storage and sterilization is accompanied by low risk of infections and resorption. Storage of autologous bone implant at a temperature of -80 ˚C with subsequent sterilization in low-temperature plasma of hydrogen peroxide can be considered as a safe and effective method for skull defect closure in children after decompressive surgery.</p>\",\"PeriodicalId\":24032,\"journal\":{\"name\":\"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17116/neiro20238704158\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhurnal voprosy neirokhirurgii imeni N. N. Burdenko","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17116/neiro20238704158","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

创伤后颅骨缺损闭合的概念是基于解剖关系的恢复,以最大限度地恢复脑功能,即它被认为是手术康复的一个阶段。儿科患者植入物的选择是有限的。在这方面,“金标准”仍然是自体骨植入。材料和方法:我们提出了一种自体骨种植体的储存和灭菌方法。最后一种方法是在充满双氧水等离子体介质的真空室中保持-80℃的灭菌温度。手术前立即进行45分钟周期的消毒。我们报告了79例使用自体骨植入物闭合颅骨缺损的病例。对自体骨植入物存放和灭菌效果的评价包括:灭菌后骨力学性能分析、术中微生物监测、术后早期感染发生率、随访并评估吸收情况。结果:2例患者出现早期感染并发症(2.5%)。6例(10.1%)发生完全吸收再手术。低温过氧化氢等离子体中的灭菌改变了骨骼的力学性能,增加了压缩应力下的耐久性,降低了拉伸条件下的耐久性。这并不影响自体骨的功能任务。所建议的储存和灭菌方法具有感染和再吸收的低风险。自体骨种植体在-80℃温度下保存,并在低温双氧水等离子体中灭菌,可以认为是一种安全有效的儿童减压术后颅骨缺损闭合方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Autologous bone implant for reconstructive surgery after decompressive craniectomy in children].

The concept of post-traumatic skull defect closure is based on restoration of anatomical relationships for the maximum possible recovery of brain function, i.e. it is considered as a stage of surgical rehabilitation. The choice of implants in pediatric patients is limited. In this regard, the «gold standard» is still autologous bone implant.

Material and methods: We propose a method for storage and sterilization of autologous bone implant. The last one implies keeping at a temperature of -80 ˚C with sterilization in a vacuum chamber filled with hydrogen peroxide vapors of biocidal plasma medium. Sterilization is provided by 45-minute cycle immediately before surgery. We report skull defect closure using autologous bone implants in 79 patients. Evaluation of effectiveness of storage and sterilization of autologous bone implant included analysis of mechanical properties of bone after sterilization, intra-operative microbiological monitoring, incidence of infections in early postoperative period, follow-up with assessment of resorption.

Results: Early infectious complications occurred in 2 patients (2.5%). Complete resorption with redo surgery occurred in 6 (10.1%) cases. Sterilization in low-temperature plasma of hydrogen peroxide changes mechanical properties of the bone, increases durability under compressive stresses and decreases durability under tensile conditions. This does not affect functional tasks of autologous bone. The proposed method of storage and sterilization is accompanied by low risk of infections and resorption. Storage of autologous bone implant at a temperature of -80 ˚C with subsequent sterilization in low-temperature plasma of hydrogen peroxide can be considered as a safe and effective method for skull defect closure in children after decompressive surgery.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
0.70
自引率
0.00%
发文量
75
期刊介绍: Scientific and practical peer-reviewed journal. This publication covers the theoretical, practical and organizational problems of modern neurosurgery, the latest advances in the treatment of various diseases of the central and peripheral nervous system. Founded in 1937. English version of the journal translates from Russian version since #1/2013.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信