根据使用双膦酸盐的患者假体类型评估骨小梁的变化:一项回顾性研究。

IF 2.5 4区 医学 Q2 Dentistry
Begüm Ünlü Kurşun, Ender Akan
{"title":"根据使用双膦酸盐的患者假体类型评估骨小梁的变化:一项回顾性研究。","authors":"Begüm Ünlü Kurşun,&nbsp;Ender Akan","doi":"10.1590/1807-3107bor-2023.vol37.0089","DOIUrl":null,"url":null,"abstract":"<p><p>The objective of the study was to retrospectively compare the fractal size values calculated in the trabecular bone according to the type of complete removable denture, removable partial denture, and partial fixed prosthesis between patients using bisphosphonates and healthy patients, retrospectively. Panoramic radiographs of a total of 200 patients, (100 using bisphosphonates,100 control group), were taken from the right and left molar regions before and after treatment with 72 × 72 pixels. The fractal dimension (FD) was computed by using ImageJ Software using the box-counting method on the images obtained. There was an interaction effect between the trabecular bone change-patient group-the type of prosthesis used and the parameters of the area (p < 0.05). In patients using complete removable dentures and removable partial dentures in the maxilla and mandibula in the molar region, a greater decrease in FD values was observed in the control group than in the patient group using bisphosphonates. An increase in FD values over time was observed in the patient group using bisphosphonates with partial fixed maxillary and mandibular prostheses compared to the control group. Partial fixed prostheses should be preferred primarily instead of complete removable or removable partial dentures in patients using bisphosphonates to prevent osteonecrosis due to dental trauma.</p>","PeriodicalId":48942,"journal":{"name":"Brazilian Oral Research","volume":null,"pages":null},"PeriodicalIF":2.5000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of trabecular bone changes according to the type of prosthesis in patients using bisphosphonates: a retrospective study.\",\"authors\":\"Begüm Ünlü Kurşun,&nbsp;Ender Akan\",\"doi\":\"10.1590/1807-3107bor-2023.vol37.0089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective of the study was to retrospectively compare the fractal size values calculated in the trabecular bone according to the type of complete removable denture, removable partial denture, and partial fixed prosthesis between patients using bisphosphonates and healthy patients, retrospectively. Panoramic radiographs of a total of 200 patients, (100 using bisphosphonates,100 control group), were taken from the right and left molar regions before and after treatment with 72 × 72 pixels. The fractal dimension (FD) was computed by using ImageJ Software using the box-counting method on the images obtained. There was an interaction effect between the trabecular bone change-patient group-the type of prosthesis used and the parameters of the area (p < 0.05). In patients using complete removable dentures and removable partial dentures in the maxilla and mandibula in the molar region, a greater decrease in FD values was observed in the control group than in the patient group using bisphosphonates. An increase in FD values over time was observed in the patient group using bisphosphonates with partial fixed maxillary and mandibular prostheses compared to the control group. Partial fixed prostheses should be preferred primarily instead of complete removable or removable partial dentures in patients using bisphosphonates to prevent osteonecrosis due to dental trauma.</p>\",\"PeriodicalId\":48942,\"journal\":{\"name\":\"Brazilian Oral Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.5000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Brazilian Oral Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1590/1807-3107bor-2023.vol37.0089\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian Oral Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1590/1807-3107bor-2023.vol37.0089","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

本研究的目的是回顾性比较使用双膦酸盐的患者和健康患者根据全可摘义齿、可摘局部义齿和部分固定义齿类型计算的小梁骨分形大小值。共200例患者(双膦酸盐组100例,对照组100例)在治疗前后取左右磨牙区全景x线片,像素为72 × 72。利用ImageJ软件对得到的图像采用盒计数法计算分形维数(FD)。骨小梁改变与患者组、使用的假体类型和面积参数之间存在交互作用(p < 0.05)。在上颌和下颌磨牙区使用可摘全口义齿和可摘局部义齿的患者中,对照组FD值的下降幅度大于使用双膦酸盐的患者组。与对照组相比,使用双膦酸盐和部分固定上颌和下颌假体的患者组的FD值随着时间的推移而增加。在使用双膦酸盐的患者中,应优先选择部分固定义齿,而不是完全可移动或可移动的局部义齿,以防止因牙齿创伤引起的骨坏死。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of trabecular bone changes according to the type of prosthesis in patients using bisphosphonates: a retrospective study.

The objective of the study was to retrospectively compare the fractal size values calculated in the trabecular bone according to the type of complete removable denture, removable partial denture, and partial fixed prosthesis between patients using bisphosphonates and healthy patients, retrospectively. Panoramic radiographs of a total of 200 patients, (100 using bisphosphonates,100 control group), were taken from the right and left molar regions before and after treatment with 72 × 72 pixels. The fractal dimension (FD) was computed by using ImageJ Software using the box-counting method on the images obtained. There was an interaction effect between the trabecular bone change-patient group-the type of prosthesis used and the parameters of the area (p < 0.05). In patients using complete removable dentures and removable partial dentures in the maxilla and mandibula in the molar region, a greater decrease in FD values was observed in the control group than in the patient group using bisphosphonates. An increase in FD values over time was observed in the patient group using bisphosphonates with partial fixed maxillary and mandibular prostheses compared to the control group. Partial fixed prostheses should be preferred primarily instead of complete removable or removable partial dentures in patients using bisphosphonates to prevent osteonecrosis due to dental trauma.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Brazilian Oral Research
Brazilian Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.70
自引率
4.00%
发文量
107
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信