评估用于基因表达分析的常规、广泛使用的EDTA血管与用于放射性和核事件准备的昂贵、专用的PAX基因管的运输条件。

IF 2.1 4区 医学 Q2 BIOLOGY
Simone Schüle, Patrick Ostheim, Razan Muhtadi, Samantha Stewart, Gwendolyn Kaletka, Cornelius Hermann, Matthias Port, Michael Abend
{"title":"评估用于基因表达分析的常规、广泛使用的EDTA血管与用于放射性和核事件准备的昂贵、专用的PAX基因管的运输条件。","authors":"Simone Schüle, Patrick Ostheim, Razan Muhtadi, Samantha Stewart, Gwendolyn Kaletka, Cornelius Hermann, Matthias Port, Michael Abend","doi":"10.1080/09553002.2023.2250871","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Gene expression (GE) analysis of a radio-sensitive gene set (<i>FDXR, DDB2, WNT3, POU2AF1</i>) has been introduced in the last decade as an early and high-throughput prediction tool of later developing acute hematologic radiation syndrome (H-ARS) severity. The use of special tubes for RNA extraction from peripheral whole blood (PAXgene) represent an established standard in GE studies, although uncommonly used in clinics and not immediately available in the quantities needed in radiological/nuclear (R/N) incidents. On the other hand, EDTA blood tubes are widely utilized in clinical practice.</p><p><strong>Material and methods: </strong>Using blood samples from eleven healthy donors, we investigated GE changes associated with delayed processing of EDTA tubes up to 4 h at room temperature (RT) after venipuncture (simulating delays caused by daily clinical routine), followed by a subsequent transport time of 24 h at RT, 4 °C, and -20 °C. Differential gene expression (DGE) of the target genes was further examined after X-irradiation with 0 Gy and 4 Gy under optimal transport conditions.</p><p><strong>Results: </strong>No significant changes in DGE were observed when storing EDTA whole blood samples up to 4 h at RT and subsequently kept at 4 °C for 24 h which is in line with expected DGE. However, other storage conditions, such as -20 °C or RT, decreased RNA quality and/or (significantly) caused changes in DGE exceeding the known methodological variance of the qRT-PCR.</p><p><strong>Conclusion: </strong>Our data indicate that the use of EDTA whole blood tubes for GE-based H-ARS severity prediction is comparable to the quality of PAXgene tubes, when processed ≤ 4 h after venipuncture and the sample is transported within 24 hours at 4 °C.</p>","PeriodicalId":14261,"journal":{"name":"International Journal of Radiation Biology","volume":" ","pages":"99-107"},"PeriodicalIF":2.1000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluating transport conditions of conventional, widely used EDTA blood tubes for gene expression analysis in comparison to expensive, specialized PAXgene tubes in preparedness for radiological and nuclear events.\",\"authors\":\"Simone Schüle, Patrick Ostheim, Razan Muhtadi, Samantha Stewart, Gwendolyn Kaletka, Cornelius Hermann, Matthias Port, Michael Abend\",\"doi\":\"10.1080/09553002.2023.2250871\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Gene expression (GE) analysis of a radio-sensitive gene set (<i>FDXR, DDB2, WNT3, POU2AF1</i>) has been introduced in the last decade as an early and high-throughput prediction tool of later developing acute hematologic radiation syndrome (H-ARS) severity. The use of special tubes for RNA extraction from peripheral whole blood (PAXgene) represent an established standard in GE studies, although uncommonly used in clinics and not immediately available in the quantities needed in radiological/nuclear (R/N) incidents. On the other hand, EDTA blood tubes are widely utilized in clinical practice.</p><p><strong>Material and methods: </strong>Using blood samples from eleven healthy donors, we investigated GE changes associated with delayed processing of EDTA tubes up to 4 h at room temperature (RT) after venipuncture (simulating delays caused by daily clinical routine), followed by a subsequent transport time of 24 h at RT, 4 °C, and -20 °C. Differential gene expression (DGE) of the target genes was further examined after X-irradiation with 0 Gy and 4 Gy under optimal transport conditions.</p><p><strong>Results: </strong>No significant changes in DGE were observed when storing EDTA whole blood samples up to 4 h at RT and subsequently kept at 4 °C for 24 h which is in line with expected DGE. However, other storage conditions, such as -20 °C or RT, decreased RNA quality and/or (significantly) caused changes in DGE exceeding the known methodological variance of the qRT-PCR.</p><p><strong>Conclusion: </strong>Our data indicate that the use of EDTA whole blood tubes for GE-based H-ARS severity prediction is comparable to the quality of PAXgene tubes, when processed ≤ 4 h after venipuncture and the sample is transported within 24 hours at 4 °C.</p>\",\"PeriodicalId\":14261,\"journal\":{\"name\":\"International Journal of Radiation Biology\",\"volume\":\" \",\"pages\":\"99-107\"},\"PeriodicalIF\":2.1000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Radiation Biology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/09553002.2023.2250871\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"BIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Radiation Biology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/09553002.2023.2250871","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"BIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:在过去的十年中,放射敏感基因集(FDXR、DDB2、WNT3、POU2AF1)的基因表达(GE)分析已被引入,作为后期发展为急性血液学放射综合征(H-ARS)严重程度的早期高通量预测工具。从外周全血(PAXgene)中提取RNA的特殊管的使用代表了通用电气研究中的既定标准,尽管在临床中很少使用,并且在放射性/核(R/N)事件中无法立即获得所需的数量。另一方面,EDTA血管在临床实践中得到了广泛的应用。材料和方法:使用来自11名健康献血者的血液样本,我们研究了与EDTA试管延迟处理长达4小时相关的GE变化 静脉穿刺后在室温(RT)下放置h(模拟日常临床常规造成的延迟),随后运输时间为24 室温下的h,4 °C和-20 °C。靶基因的差异基因表达(DGE)在用0 Gy和4 Gy。结果:当EDTA全血样品储存至4小时时,DGE没有观察到显著变化 在RT下为h,随后保持在4 °C 24 h,这与预期的DGE一致。但是,其他储存条件,如-20 °C或RT,降低RNA质量和/或(显著)导致DGE变化超过qRT-PCR的已知方法学方差。结论:我们的数据表明,使用EDTA全血管进行基于GE的H-ARS严重程度预测与PAX基因管的质量相当,当处理≤4 静脉穿刺后h,样品在24小时内运输 4小时 °C。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluating transport conditions of conventional, widely used EDTA blood tubes for gene expression analysis in comparison to expensive, specialized PAXgene tubes in preparedness for radiological and nuclear events.

Purpose: Gene expression (GE) analysis of a radio-sensitive gene set (FDXR, DDB2, WNT3, POU2AF1) has been introduced in the last decade as an early and high-throughput prediction tool of later developing acute hematologic radiation syndrome (H-ARS) severity. The use of special tubes for RNA extraction from peripheral whole blood (PAXgene) represent an established standard in GE studies, although uncommonly used in clinics and not immediately available in the quantities needed in radiological/nuclear (R/N) incidents. On the other hand, EDTA blood tubes are widely utilized in clinical practice.

Material and methods: Using blood samples from eleven healthy donors, we investigated GE changes associated with delayed processing of EDTA tubes up to 4 h at room temperature (RT) after venipuncture (simulating delays caused by daily clinical routine), followed by a subsequent transport time of 24 h at RT, 4 °C, and -20 °C. Differential gene expression (DGE) of the target genes was further examined after X-irradiation with 0 Gy and 4 Gy under optimal transport conditions.

Results: No significant changes in DGE were observed when storing EDTA whole blood samples up to 4 h at RT and subsequently kept at 4 °C for 24 h which is in line with expected DGE. However, other storage conditions, such as -20 °C or RT, decreased RNA quality and/or (significantly) caused changes in DGE exceeding the known methodological variance of the qRT-PCR.

Conclusion: Our data indicate that the use of EDTA whole blood tubes for GE-based H-ARS severity prediction is comparable to the quality of PAXgene tubes, when processed ≤ 4 h after venipuncture and the sample is transported within 24 hours at 4 °C.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.00
自引率
11.50%
发文量
142
审稿时长
3 months
期刊介绍: The International Journal of Radiation Biology publishes original papers, reviews, current topic articles, technical notes/reports, and meeting reports on the effects of ionizing, UV and visible radiation, accelerated particles, electromagnetic fields, ultrasound, heat and related modalities. The focus is on the biological effects of such radiations: from radiation chemistry to the spectrum of responses of living organisms and underlying mechanisms, including genetic abnormalities, repair phenomena, cell death, dose modifying agents and tissue responses. Application of basic studies to medical uses of radiation extends the coverage to practical problems such as physical and chemical adjuvants which improve the effectiveness of radiation in cancer therapy. Assessment of the hazards of low doses of radiation is also considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信