Koji Moriya, Yutaka Maki, Hisao Koda, Takuma Kuroda, Naoto Tsubokawa
{"title":"缝合线方向对屈肌腱修复后抗拉强度的影响。","authors":"Koji Moriya, Yutaka Maki, Hisao Koda, Takuma Kuroda, Naoto Tsubokawa","doi":"10.1177/17531934231186011","DOIUrl":null,"url":null,"abstract":"<p><p>We assessed the influence of different directions of suture strands using the double Tsuge repair on the resistance to gap formation and mode of failure. In total, 25 porcine flexor digitorum profundus tendons were split into two groups. One group was repaired using a conventional double Tsuge suture created by two bands of looped suture placed longitudinally parallel (parallel method), and the other group was repaired using a new technique comprising two bands of looped suture placed in a crossed fashion in the anterior and posterior half of the tendon (cruciate method). The repaired tendons were subjected to linear, non-cyclic load-to-failure tensile testing. The cruciate method had a significantly higher mean load at a 2-mm gap tensile load (29.7 N [SD, 8.3]) than the parallel method (21.6 N [SD, 4.9]) and failed significantly more often due to suture pull-out. The direction of a core suture and its location within the tendon affect both gap resistance and the mode of failure of repair when using the double Tsuge suture technique, with a cruciate configuration achieving a greater gap resistance than a parallel one.</p>","PeriodicalId":54813,"journal":{"name":"Journal of Hand Surgery-European Volume","volume":" ","pages":"1074-1079"},"PeriodicalIF":2.0000,"publicationDate":"2023-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of the direction of suture strands on the tensile strength after flexor tendon repairs.\",\"authors\":\"Koji Moriya, Yutaka Maki, Hisao Koda, Takuma Kuroda, Naoto Tsubokawa\",\"doi\":\"10.1177/17531934231186011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We assessed the influence of different directions of suture strands using the double Tsuge repair on the resistance to gap formation and mode of failure. In total, 25 porcine flexor digitorum profundus tendons were split into two groups. One group was repaired using a conventional double Tsuge suture created by two bands of looped suture placed longitudinally parallel (parallel method), and the other group was repaired using a new technique comprising two bands of looped suture placed in a crossed fashion in the anterior and posterior half of the tendon (cruciate method). The repaired tendons were subjected to linear, non-cyclic load-to-failure tensile testing. The cruciate method had a significantly higher mean load at a 2-mm gap tensile load (29.7 N [SD, 8.3]) than the parallel method (21.6 N [SD, 4.9]) and failed significantly more often due to suture pull-out. The direction of a core suture and its location within the tendon affect both gap resistance and the mode of failure of repair when using the double Tsuge suture technique, with a cruciate configuration achieving a greater gap resistance than a parallel one.</p>\",\"PeriodicalId\":54813,\"journal\":{\"name\":\"Journal of Hand Surgery-European Volume\",\"volume\":\" \",\"pages\":\"1074-1079\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2023-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Hand Surgery-European Volume\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/17531934231186011\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/7 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Hand Surgery-European Volume","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/17531934231186011","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/7 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Influence of the direction of suture strands on the tensile strength after flexor tendon repairs.
We assessed the influence of different directions of suture strands using the double Tsuge repair on the resistance to gap formation and mode of failure. In total, 25 porcine flexor digitorum profundus tendons were split into two groups. One group was repaired using a conventional double Tsuge suture created by two bands of looped suture placed longitudinally parallel (parallel method), and the other group was repaired using a new technique comprising two bands of looped suture placed in a crossed fashion in the anterior and posterior half of the tendon (cruciate method). The repaired tendons were subjected to linear, non-cyclic load-to-failure tensile testing. The cruciate method had a significantly higher mean load at a 2-mm gap tensile load (29.7 N [SD, 8.3]) than the parallel method (21.6 N [SD, 4.9]) and failed significantly more often due to suture pull-out. The direction of a core suture and its location within the tendon affect both gap resistance and the mode of failure of repair when using the double Tsuge suture technique, with a cruciate configuration achieving a greater gap resistance than a parallel one.
期刊介绍:
The Journal of Hand Surgery (European Volume) is essential reading for everyone involved in restoring the function to the hand and upper limb. Dedicated to the needs of hand, plastic, reconstructive and orthopaedic surgeons, it publishes the best selection of current papers on hand surgery.
The journal regularly highlights key developments in a range of original, authoritative and highly informative articles written by distinguished experts from around the world. Rapid coverage of the latest research, techniques, trends and ideas to make sure you stay up-to-date.
Subjects covered include:
joint replacement
fracture and joint injuries
microvascular surgery
congenital hand problems
You will also find editorials, book reviews, conference dates, case studies, detailed coverage of new techniques and full-length reviews articles.