Lene Nyhus Andreasen, Evald Høj Christiansen, Lone Juul Hune Mogensen, Niels Ramsing Holm
{"title":"比较冠状动脉参考尺寸的定义以及对支架选择和支架扩张评估的影响。","authors":"Lene Nyhus Andreasen, Evald Høj Christiansen, Lone Juul Hune Mogensen, Niels Ramsing Holm","doi":"10.1007/s10554-023-02890-2","DOIUrl":null,"url":null,"abstract":"<p><p>Accurate determination of coronary reference size is essential for optimal stent selection and evaluation of stent expansion during percutaneous coronary intervention (PCI). Several approaches for reference size estimation have been published with no universal agreement. The aim of this study was to investigate if potential differences in coronary reference size estimation lead to differences in stent and balloon selection and in detection of stent under expansion. Definitions for coronary reference size estimation, stent size selection, and stent expansion were identified in 17 randomized controlled trials. The identified methods were applied in a population of 32 clinical cases. Reference size estimates ranged up to 1.35mm, and indicated nominal stent size ranged up to 1.0 mm in the same case depending on method. Mean relative stent expansion ranged from 54±12% to mean 100±29% depending on the applied reference method. Choice of method for reference size estimation using intravascular imaging may influence stent selection and greatly affects evaluation of post-PCI stent expansion.</p>","PeriodicalId":50332,"journal":{"name":"International Journal of Cardiovascular Imaging","volume":" ","pages":"1825-1837"},"PeriodicalIF":1.5000,"publicationDate":"2023-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520108/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparison of definitions of coronary artery reference sizes and effects on stent selection and evaluation of stent expansion.\",\"authors\":\"Lene Nyhus Andreasen, Evald Høj Christiansen, Lone Juul Hune Mogensen, Niels Ramsing Holm\",\"doi\":\"10.1007/s10554-023-02890-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Accurate determination of coronary reference size is essential for optimal stent selection and evaluation of stent expansion during percutaneous coronary intervention (PCI). Several approaches for reference size estimation have been published with no universal agreement. The aim of this study was to investigate if potential differences in coronary reference size estimation lead to differences in stent and balloon selection and in detection of stent under expansion. Definitions for coronary reference size estimation, stent size selection, and stent expansion were identified in 17 randomized controlled trials. The identified methods were applied in a population of 32 clinical cases. Reference size estimates ranged up to 1.35mm, and indicated nominal stent size ranged up to 1.0 mm in the same case depending on method. Mean relative stent expansion ranged from 54±12% to mean 100±29% depending on the applied reference method. Choice of method for reference size estimation using intravascular imaging may influence stent selection and greatly affects evaluation of post-PCI stent expansion.</p>\",\"PeriodicalId\":50332,\"journal\":{\"name\":\"International Journal of Cardiovascular Imaging\",\"volume\":\" \",\"pages\":\"1825-1837\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10520108/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Cardiovascular Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s10554-023-02890-2\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/7/5 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Cardiovascular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s10554-023-02890-2","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/7/5 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Comparison of definitions of coronary artery reference sizes and effects on stent selection and evaluation of stent expansion.
Accurate determination of coronary reference size is essential for optimal stent selection and evaluation of stent expansion during percutaneous coronary intervention (PCI). Several approaches for reference size estimation have been published with no universal agreement. The aim of this study was to investigate if potential differences in coronary reference size estimation lead to differences in stent and balloon selection and in detection of stent under expansion. Definitions for coronary reference size estimation, stent size selection, and stent expansion were identified in 17 randomized controlled trials. The identified methods were applied in a population of 32 clinical cases. Reference size estimates ranged up to 1.35mm, and indicated nominal stent size ranged up to 1.0 mm in the same case depending on method. Mean relative stent expansion ranged from 54±12% to mean 100±29% depending on the applied reference method. Choice of method for reference size estimation using intravascular imaging may influence stent selection and greatly affects evaluation of post-PCI stent expansion.
期刊介绍:
The International Journal of Cardiovascular Imaging publishes technical and clinical communications (original articles, review articles and editorial comments) associated with cardiovascular diseases. The technical communications include the research, development and evaluation of novel imaging methods in the various imaging domains. These domains include magnetic resonance imaging, computed tomography, X-ray imaging, intravascular imaging, and applications in nuclear cardiology and echocardiography, and any combination of these techniques. Of particular interest are topics in medical image processing and image-guided interventions. Clinical applications of such imaging techniques include improved diagnostic approaches, treatment , prognosis and follow-up of cardiovascular patients. Topics include: multi-center or larger individual studies dealing with risk stratification and imaging utilization, applications for better characterization of cardiovascular diseases, and assessment of the efficacy of new drugs and interventional devices.