Reihaneh Ravari, Mayank Rehani, Jacqueline S Hebert
{"title":"步态期间经股骨固定假体的生物力学特征:文献综述。","authors":"Reihaneh Ravari, Mayank Rehani, Jacqueline S Hebert","doi":"10.1097/PXR.0000000000000263","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Osseointegration (OI) is an emerging technique that allows a direct connection between the bone and a titanium metal implant, allowing the direct attachment of bone-anchored prostheses (BAP) to address the problems associated with socket prostheses. This review article aims to compare the biomechanical features of gait when using a transfemoral BAP in comparison to healthy gait, and in comparison to the gait of traditional transfemoral socket prosthesis users.</p><p><strong>Methods: </strong>A computer-based literature search of electronic databases since inception (ranging from 1967 to 2004 depending on the database) to June 14, 2022, identified peer-reviewed articles focusing on the temporal-spatial, kinematic, kinetic, and electromyography data related to transfemoral BAP gait. Eight articles were included that focused on these biomechanical features of gait in adults with BAP and were compared with socket prosthesis users or healthy gait.</p><p><strong>Results: </strong>Compared with healthy participants, prosthesis users after OI surgery have slower speed and cadence, lower symmetry, longer duration of swing phase, increased pelvic and trunk motion, more hip extension, larger moments on the intact limb, and lower forces on the prosthetic side. Compared with transfemoral socket prosthesis gait, BAP gait shows faster cadence and longer duration of support phase. There are limited and inconsistent data on changes in trunk, pelvic, and hip motion with OI.</p><p><strong>Conclusion: </strong>Based on this review, transfemoral BAP improve spatial-temporal parameters closer to normal gait when compared to socket gait, but there are persisting deficits compared with healthy gait. Additional studies are needed to confirm the changes in kinematics and kinetics when walking with a BAP.</p>","PeriodicalId":49657,"journal":{"name":"Prosthetics and Orthotics International","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Biomechanical characteristics of transfemoral bone-anchored prostheses during gait: A review of literature.\",\"authors\":\"Reihaneh Ravari, Mayank Rehani, Jacqueline S Hebert\",\"doi\":\"10.1097/PXR.0000000000000263\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Osseointegration (OI) is an emerging technique that allows a direct connection between the bone and a titanium metal implant, allowing the direct attachment of bone-anchored prostheses (BAP) to address the problems associated with socket prostheses. This review article aims to compare the biomechanical features of gait when using a transfemoral BAP in comparison to healthy gait, and in comparison to the gait of traditional transfemoral socket prosthesis users.</p><p><strong>Methods: </strong>A computer-based literature search of electronic databases since inception (ranging from 1967 to 2004 depending on the database) to June 14, 2022, identified peer-reviewed articles focusing on the temporal-spatial, kinematic, kinetic, and electromyography data related to transfemoral BAP gait. Eight articles were included that focused on these biomechanical features of gait in adults with BAP and were compared with socket prosthesis users or healthy gait.</p><p><strong>Results: </strong>Compared with healthy participants, prosthesis users after OI surgery have slower speed and cadence, lower symmetry, longer duration of swing phase, increased pelvic and trunk motion, more hip extension, larger moments on the intact limb, and lower forces on the prosthetic side. Compared with transfemoral socket prosthesis gait, BAP gait shows faster cadence and longer duration of support phase. There are limited and inconsistent data on changes in trunk, pelvic, and hip motion with OI.</p><p><strong>Conclusion: </strong>Based on this review, transfemoral BAP improve spatial-temporal parameters closer to normal gait when compared to socket gait, but there are persisting deficits compared with healthy gait. Additional studies are needed to confirm the changes in kinematics and kinetics when walking with a BAP.</p>\",\"PeriodicalId\":49657,\"journal\":{\"name\":\"Prosthetics and Orthotics International\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Prosthetics and Orthotics International\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/PXR.0000000000000263\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/8/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ORTHOPEDICS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prosthetics and Orthotics International","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/PXR.0000000000000263","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/8/25 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ORTHOPEDICS","Score":null,"Total":0}
Biomechanical characteristics of transfemoral bone-anchored prostheses during gait: A review of literature.
Background: Osseointegration (OI) is an emerging technique that allows a direct connection between the bone and a titanium metal implant, allowing the direct attachment of bone-anchored prostheses (BAP) to address the problems associated with socket prostheses. This review article aims to compare the biomechanical features of gait when using a transfemoral BAP in comparison to healthy gait, and in comparison to the gait of traditional transfemoral socket prosthesis users.
Methods: A computer-based literature search of electronic databases since inception (ranging from 1967 to 2004 depending on the database) to June 14, 2022, identified peer-reviewed articles focusing on the temporal-spatial, kinematic, kinetic, and electromyography data related to transfemoral BAP gait. Eight articles were included that focused on these biomechanical features of gait in adults with BAP and were compared with socket prosthesis users or healthy gait.
Results: Compared with healthy participants, prosthesis users after OI surgery have slower speed and cadence, lower symmetry, longer duration of swing phase, increased pelvic and trunk motion, more hip extension, larger moments on the intact limb, and lower forces on the prosthetic side. Compared with transfemoral socket prosthesis gait, BAP gait shows faster cadence and longer duration of support phase. There are limited and inconsistent data on changes in trunk, pelvic, and hip motion with OI.
Conclusion: Based on this review, transfemoral BAP improve spatial-temporal parameters closer to normal gait when compared to socket gait, but there are persisting deficits compared with healthy gait. Additional studies are needed to confirm the changes in kinematics and kinetics when walking with a BAP.
期刊介绍:
Prosthetics and Orthotics International is an international, multidisciplinary journal for all professionals who have an interest in the medical, clinical, rehabilitation, technical, educational and research aspects of prosthetics, orthotics and rehabilitation engineering, as well as their related topics.