Lucia Kottmann, Rene Franzen, Georg Conrads, Stefan Wolfart, Juliana Marotti
{"title":"侧射Er,Cr:YSGG激光对钛盘表面去污效果的体内外研究","authors":"Lucia Kottmann, Rene Franzen, Georg Conrads, Stefan Wolfart, Juliana Marotti","doi":"10.1186/s40729-023-00469-z","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc.</p><p><strong>Methods: </strong>In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures.</p><p><strong>Results: </strong>The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379).</p><p><strong>Conclusion: </strong>The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.</p>","PeriodicalId":14076,"journal":{"name":"International Journal of Implant Dentistry","volume":null,"pages":null},"PeriodicalIF":3.1000,"publicationDate":"2023-02-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10110821/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study.\",\"authors\":\"Lucia Kottmann, Rene Franzen, Georg Conrads, Stefan Wolfart, Juliana Marotti\",\"doi\":\"10.1186/s40729-023-00469-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc.</p><p><strong>Methods: </strong>In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures.</p><p><strong>Results: </strong>The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379).</p><p><strong>Conclusion: </strong>The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.</p>\",\"PeriodicalId\":14076,\"journal\":{\"name\":\"International Journal of Implant Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2023-02-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10110821/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Implant Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40729-023-00469-z\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40729-023-00469-z","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study.
Purpose: To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc.
Methods: In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures.
Results: The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379).
Conclusion: The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.
期刊介绍:
The International Journal of Implant Dentistry is a peer-reviewed open access journal published under the SpringerOpen brand. The journal is dedicated to promoting the exchange and discussion of all research areas relevant to implant dentistry in the form of systematic literature or invited reviews, prospective and retrospective clinical studies, clinical case reports, basic laboratory and animal research, and articles on material research and engineering.