成人弱视患者摘除透明晶状体后视力的变化。

Q4 Medicine
J Halička, R Vida, M Gajdoš, M Králik, M Javorka, L Jančo, P Žiak
{"title":"成人弱视患者摘除透明晶状体后视力的变化。","authors":"J Halička,&nbsp;R Vida,&nbsp;M Gajdoš,&nbsp;M Králik,&nbsp;M Javorka,&nbsp;L Jančo,&nbsp;P Žiak","doi":"10.31348/2023/17","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The aim of the study was to retrospectively evaluate changes in vision after the implantation of trifocal (tIOL) or rotationally asymmetric multifocal artificial intraocular lenses (mIOL) in patients undergoing clear lens extraction. The main goal was to determine whether changes to central visual acuity occur after the implantation of an IOL at a follow-up examination after one year. Other objectives were to determine the difference between the groups with implanted diffractive and rotationally asymmetric artificial intraocular lenses, as well as to evaluate the risk of accurate correction in patients who had lived most of their lives \"undercorrected\".</p><p><strong>Material and methods: </strong>In our study, we present a retrospective longitudinal evaluation of results in patients after the implantation of an artificial intraocular lens. In the period from 2013 to 2020, we evaluated changes in the vision of 22 patients aged 39-59 years, of whom 18 were women and 5 were men. The average preoperative refraction of myopic eyes was +5.7 ±2.13 Dsf and +1.24 ±0.86 Dcyl. In amblyopic eyes, 7 diffractive lenses and 15 rotationally asymmetric lenses were used.</p><p><strong>Results: </strong>Uncorrected distance visual acuity before surgery and one year (1Y) after was 0.13 ±0.09 vs. 0.57 ±0.28 (p &lt; 0.001); the best corrected distance visual acuity before and 1Y after was 0.53 ±0.22 vs. 0.62 ±0.29 (p = 0.024); uncorrected near visual acuity before and 1Y after was 0.06 ±0.06 vs. 0.48 ±0.32 (p &lt; 0.001); the best corrected near visual acuity before and afér the surgical procedure was 0.45 ±0.27vs. 0.55 ±0.35 (p = 0.014).</p><p><strong>Conclusion: </strong>Implantation of tIOL and mIOL lenses was effective in our group of patients with amblyopia, thus improving uncorrected distance and near visual acuity and without serious adverse effects. At the same time, we evaluate that the change in refraction and the removal of anisometropia lead to a significant change in the best corrected visual acuity for distance or near vision at the one-year follow-up examination.</p>","PeriodicalId":39839,"journal":{"name":"Ceska a Slovenska Oftalmologie","volume":"79 3","pages":"118-123"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"CHANGES IN THE VISION OF ADULT AMBLYOPIC PATIENTS FOLLOWING CLEAR LENS EXTRACTION.\",\"authors\":\"J Halička,&nbsp;R Vida,&nbsp;M Gajdoš,&nbsp;M Králik,&nbsp;M Javorka,&nbsp;L Jančo,&nbsp;P Žiak\",\"doi\":\"10.31348/2023/17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>The aim of the study was to retrospectively evaluate changes in vision after the implantation of trifocal (tIOL) or rotationally asymmetric multifocal artificial intraocular lenses (mIOL) in patients undergoing clear lens extraction. The main goal was to determine whether changes to central visual acuity occur after the implantation of an IOL at a follow-up examination after one year. Other objectives were to determine the difference between the groups with implanted diffractive and rotationally asymmetric artificial intraocular lenses, as well as to evaluate the risk of accurate correction in patients who had lived most of their lives \\\"undercorrected\\\".</p><p><strong>Material and methods: </strong>In our study, we present a retrospective longitudinal evaluation of results in patients after the implantation of an artificial intraocular lens. In the period from 2013 to 2020, we evaluated changes in the vision of 22 patients aged 39-59 years, of whom 18 were women and 5 were men. The average preoperative refraction of myopic eyes was +5.7 ±2.13 Dsf and +1.24 ±0.86 Dcyl. In amblyopic eyes, 7 diffractive lenses and 15 rotationally asymmetric lenses were used.</p><p><strong>Results: </strong>Uncorrected distance visual acuity before surgery and one year (1Y) after was 0.13 ±0.09 vs. 0.57 ±0.28 (p &lt; 0.001); the best corrected distance visual acuity before and 1Y after was 0.53 ±0.22 vs. 0.62 ±0.29 (p = 0.024); uncorrected near visual acuity before and 1Y after was 0.06 ±0.06 vs. 0.48 ±0.32 (p &lt; 0.001); the best corrected near visual acuity before and afér the surgical procedure was 0.45 ±0.27vs. 0.55 ±0.35 (p = 0.014).</p><p><strong>Conclusion: </strong>Implantation of tIOL and mIOL lenses was effective in our group of patients with amblyopia, thus improving uncorrected distance and near visual acuity and without serious adverse effects. At the same time, we evaluate that the change in refraction and the removal of anisometropia lead to a significant change in the best corrected visual acuity for distance or near vision at the one-year follow-up examination.</p>\",\"PeriodicalId\":39839,\"journal\":{\"name\":\"Ceska a Slovenska Oftalmologie\",\"volume\":\"79 3\",\"pages\":\"118-123\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ceska a Slovenska Oftalmologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.31348/2023/17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ceska a Slovenska Oftalmologie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.31348/2023/17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是回顾性评价接受透明晶状体摘出术的患者在植入三焦(tIOL)或旋转不对称多焦人工晶状体(mIOL)后视力的变化。主要目的是在一年后的随访检查中确定人工晶状体植入后中央视力是否发生变化。其他目的是确定植入衍射和旋转不对称人工晶状体组之间的差异,以及评估那些大部分时间都处于“未矫正”状态的患者进行准确矫正的风险。材料和方法:在我们的研究中,我们对人工晶状体植入术后的患者进行了回顾性的纵向评价。在2013年至2020年期间,我们评估了22名年龄在39-59岁之间的患者的视力变化,其中18名女性,5名男性。术前近视眼平均屈光度分别为+5.7±2.13 Dsf和+1.24±0.86 Dcyl。弱视采用衍射晶状体7枚,旋转非对称晶状体15枚。结果:术前和术后1年(1Y)未矫正距离视力分别为0.13±0.09和0.57±0.28 (p <0.001);治疗前和治疗后1Y的最佳矫正距离视力分别为0.53±0.22和0.62±0.29 (p = 0.024);术前、术后1Y未矫正近视力分别为0.06±0.06∶0.48±0.32 (p <0.001);手术前后最佳矫正近视力为0.45±0.27。0.55±0.35 (p = 0.014)。结论:本组弱视患者行tIOL和mIOL晶状体植入术,可改善未矫正的远近视力,无严重不良反应。同时,在一年的随访检查中,我们评估了屈光的改变和屈光参差的去除导致远处或近处最佳矫正视力的显著变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
CHANGES IN THE VISION OF ADULT AMBLYOPIC PATIENTS FOLLOWING CLEAR LENS EXTRACTION.

Aims: The aim of the study was to retrospectively evaluate changes in vision after the implantation of trifocal (tIOL) or rotationally asymmetric multifocal artificial intraocular lenses (mIOL) in patients undergoing clear lens extraction. The main goal was to determine whether changes to central visual acuity occur after the implantation of an IOL at a follow-up examination after one year. Other objectives were to determine the difference between the groups with implanted diffractive and rotationally asymmetric artificial intraocular lenses, as well as to evaluate the risk of accurate correction in patients who had lived most of their lives "undercorrected".

Material and methods: In our study, we present a retrospective longitudinal evaluation of results in patients after the implantation of an artificial intraocular lens. In the period from 2013 to 2020, we evaluated changes in the vision of 22 patients aged 39-59 years, of whom 18 were women and 5 were men. The average preoperative refraction of myopic eyes was +5.7 ±2.13 Dsf and +1.24 ±0.86 Dcyl. In amblyopic eyes, 7 diffractive lenses and 15 rotationally asymmetric lenses were used.

Results: Uncorrected distance visual acuity before surgery and one year (1Y) after was 0.13 ±0.09 vs. 0.57 ±0.28 (p < 0.001); the best corrected distance visual acuity before and 1Y after was 0.53 ±0.22 vs. 0.62 ±0.29 (p = 0.024); uncorrected near visual acuity before and 1Y after was 0.06 ±0.06 vs. 0.48 ±0.32 (p < 0.001); the best corrected near visual acuity before and afér the surgical procedure was 0.45 ±0.27vs. 0.55 ±0.35 (p = 0.014).

Conclusion: Implantation of tIOL and mIOL lenses was effective in our group of patients with amblyopia, thus improving uncorrected distance and near visual acuity and without serious adverse effects. At the same time, we evaluate that the change in refraction and the removal of anisometropia lead to a significant change in the best corrected visual acuity for distance or near vision at the one-year follow-up examination.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ceska a Slovenska Oftalmologie
Ceska a Slovenska Oftalmologie Medicine-Ophthalmology
CiteScore
0.80
自引率
0.00%
发文量
0
期刊介绍: - Redakce přijímá pouze práce vyhovující po odborné stránce, které jsou na odpovídající profesionální a formální úrovni. - Uveřejněná práce se stává majetkem časopisu, přetisknout její část nebo obrázek lze jen s citací původu. - Rukopis zasílejte v originále a dobře čitelné kopii (je nutná také kopie tabulek, legend, podle možnosti i obrázků). - Listy číslujte v pravém horním rohu a spojujte svorkou, nesešívejte. Přijímáme práce psané na jedné straně kvalitního bílého nelesklého papíru formátu A4 (neprůklepový) na psacím stroji nebo počítači s obvyklými typy.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信