Study of Electro-osmotic flow in microfluidic devices 微流体装置中电渗透流动的研究
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360115
Romena Sabur, M. A. Matin
{"title":"Study of Electro-osmotic flow in microfluidic devices","authors":"Romena Sabur, M. A. Matin","doi":"10.1109/ISSMDBS.2006.360115","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360115","url":null,"abstract":"Several fluid movement techniques in microchannel have been introduced in the past, the most recent technique is by applying an electric field to a fluid enclosed between capillary surfaces. This technique is called electrokinetically driven flow. The modeling and simulation of electrokinetic transports of fluid in various typical micro-channel geometries such as T-channel, L-channel, and curved channel were done in this paper using commercial simulation software Coventorwarereg. The study has focused on finding the effects of electroosmotic forces on the micro-scale flow fields, and flow control of electroosmotic flow in micro-geometries including the dispersion of liquid flow in the micro channels of different geometries.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130146135","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
Magnetic and Capacitive Monitoring of Heart and Lung Activity as an Example for Personal Healthcare 磁性和电容监测心肺活动作为个人医疗保健的一个例子
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360096
S. Leonhardt, A. Aleksandrowicz, M. Steffen
{"title":"Magnetic and Capacitive Monitoring of Heart and Lung Activity as an Example for Personal Healthcare","authors":"S. Leonhardt, A. Aleksandrowicz, M. Steffen","doi":"10.1109/ISSMDBS.2006.360096","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360096","url":null,"abstract":"This paper provides first experimental results on two methods for non-conductive monitoring of heart and lung activity that bear the potential for mobile application in a personal healthcare scenario. Specifically, the paper reports on the techniques and on some preliminary results for magnetic bioimpedance monitoring and capacitive ECG recording. Draw-backs and limitations of these methods as well as future work to improve these techniques are discussed.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"23 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"121200877","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 10
Estimation of sleeping posture for M-Health by a wearable tri-axis accelerometer 用可穿戴三轴加速度计估计M-Health的睡眠姿势
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360093
Y. Kishimoto, A. Akahori, Koji Oguri
{"title":"Estimation of sleeping posture for M-Health by a wearable tri-axis accelerometer","authors":"Y. Kishimoto, A. Akahori, Koji Oguri","doi":"10.1109/ISSMDBS.2006.360093","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360093","url":null,"abstract":"Sensor technology has been developed for measuring daily activity. Measurement instruments of all kinds have continued to become much smaller, consume less power, and increase in resolution and/or sensitivity. This study proposed a way to detect sleeping postures from data acquired using a tri-axis accelerometer strapped to subject's chest. We defined sleeping postures as five states focusing on basal-surface, which indicates the place of human's body on the ground. An evaluation was performed both manually by a technician and automatically by designed software. Results is that the accelerometer allowed us to accurately classify postures. Changes in posture were detected with a mean error of less than 3 s, which is acceptable for clinical cardiovascular applications.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"19 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115692536","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 18
The Challenge of Motion Artifact Suppression in Wearable Monitoring Solutions 运动伪影抑制在可穿戴监测解决方案中的挑战
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360094
O. Such, J. Muehlsteff
{"title":"The Challenge of Motion Artifact Suppression in Wearable Monitoring Solutions","authors":"O. Such, J. Muehlsteff","doi":"10.1109/ISSMDBS.2006.360094","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360094","url":null,"abstract":"Motion artifact is a major limitation in most practical implementations of wearable health monitoring devices. Especially in applications requiring continuous monitoring and high specificity, motion artifact can render a solution infeasible in real world use cases. We believe that the single most important technical challenge that will decide the success of wearable biomedical sensor systems is signal integrity. Principle possibilities to reduce artifact are explained, and some historical and modern examples are given, showing the relevance of this subject. However, still no proper models for artifact exist, nor is there a generalized approach to deal with this problem. This paper intends to call to attention the need for a common understanding in the community for a method of addressing this area objectively, and proposes next steps toward this goal.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"54 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127035026","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 25
Sensing Fabrics for Monitoring Physiological and Biomechanical Variables: E-textile solutions 监测生理和生物力学变量的传感织物:电子纺织品解决方案
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360082
M. Pacelli, G. Loriga, N. Taccini, R. Paradiso
{"title":"Sensing Fabrics for Monitoring Physiological and Biomechanical Variables: E-textile solutions","authors":"M. Pacelli, G. Loriga, N. Taccini, R. Paradiso","doi":"10.1109/ISSMDBS.2006.360082","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360082","url":null,"abstract":"In this paper is reported the experience gained in the last five years, in the implementation of wearable systems for personalized health care and their evolution in time. Sensing bio clothes for vital signs monitoring and wearable systems for gesture and posture recognition are specifically illustrated, resulting from the EU funded projects: Wealthy and My Heart.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"16 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125596887","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 172
The Design of Medical Assistant System for Ward Doctors 病房医生医疗辅助系统的设计
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360110
Jiehui Jiang, Zhuangzhi Yan, Jun Shi
{"title":"The Design of Medical Assistant System for Ward Doctors","authors":"Jiehui Jiang, Zhuangzhi Yan, Jun Shi","doi":"10.1109/ISSMDBS.2006.360110","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360110","url":null,"abstract":"To help the ward doctors care inpatients better, a medical assistant system is designed in this paper. The functions of this system include basic information (electronic records) operation and healthcare information (ECG, Pulse, etc.,) measurement. Comparing with the conventional systems, our system is at a low cost because no special hardware or software is needed, and a personal digital assistant (PDA) or tablet personal computer can be used as the doctor's terminal. The current system is composed with three parts: the measurement system for health information, the server side in doctor's office and the client side for ward doctors. The system has been tested in the experiment and a wireless LAN is used as the transferring condition.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"133299483","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
Using the Surgery Suturing Progress Consequences to Design a Minimally Invasive Suturing Device 利用手术缝合进展的结果设计一种微创缝合装置
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360117
S. H. Farkoush
{"title":"Using the Surgery Suturing Progress Consequences to Design a Minimally Invasive Suturing Device","authors":"S. H. Farkoush","doi":"10.1109/ISSMDBS.2006.360117","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360117","url":null,"abstract":"Device form and operation conditions make some constraints for surgeon during MIS. Performing some of these tasks automatically will help to provide a precise and fast operation. In this paper we will consider the endoscopic suturing task as the case study which can be operated automatically by a smart suturing device. The standard procedures in performing a conventional suturing task are derived by analyzing this type of operation. An automatic system is designed based on this information. Then the performance of the system is evaluated.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"115352765","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Modeling of the Cuffless Blood Pressure Measurement Errors for the Evaluation of a Wearable Medical Device 可穿戴医疗设备无袖带血压测量误差建模
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360109
X. Xiang, Carmen C. Y. Poon, Yuan-ting Zhang
{"title":"Modeling of the Cuffless Blood Pressure Measurement Errors for the Evaluation of a Wearable Medical Device","authors":"X. Xiang, Carmen C. Y. Poon, Yuan-ting Zhang","doi":"10.1109/ISSMDBS.2006.360109","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360109","url":null,"abstract":"The two widely used standards for validating the conventional cuff-based BP devices are those set up by the American Association for the Advancement of Medical Instrumentation (AAMI) and the British Hypertension Society (BHS) respectively. It was reported that although both standards work well for most BP devices, they do not agree with each other in all circumstances. Previous attempts to model the measurement errors as Gaussian could not explain the phenomena. Results of this study indicate that the general t distribution fits better to the BP measurement errors reported in previous literatures and collected from our clinical experiments. Furthermore, the theoretical mapping of the AAMI accuracy criteria and BHS grading system derived from the t distribution model can better reflect the real situations, where some devices can pass the BHS criteria but fail that of the AAMI. Based on this mapping relationship, it is found that current standards work well for devices with error distribution close to Gaussian but they may not be suitable for the newly developed wearable BP measuring devices used in the experiment, where the errors followed a t distribution with a smaller degree of freedom. It is suggested that a statistical measure that takes into account both the probability and the absolute value of the extreme errors could be introduced into the standard in order to better evaluate this kind of wearable, cuffless BP measuring devices.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"39 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"116300520","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 7
A Broad Range of New Clinical Applications for a Magnetic Sensor Measuring Distance on the Human Body 一种测量人体距离的磁传感器的广泛临床应用
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360100
E. Graas, V. Remouchamps, D. Dive, R. Poirrier
{"title":"A Broad Range of New Clinical Applications for a Magnetic Sensor Measuring Distance on the Human Body","authors":"E. Graas, V. Remouchamps, D. Dive, R. Poirrier","doi":"10.1109/ISSMDBS.2006.360100","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360100","url":null,"abstract":"This paper describes the features of a magnetic distance meter initially intended to detect sleep-related breathing efforts through the recording and analysis of jaw movements. The design of the device made it a very sensitive, non-invasive, wearable and easy-to-use motion detector. As such, it rapidly became an interesting equipment in wholly different clinical domains like radiotherapy and biomechanics. The new prospects offered by this magnetic motion-sensing solution in various clinical applications are presented and discussed here.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"13 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"114259539","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Design Concept of Clothing Recognizing Back Postures 识别背部姿势的服装设计理念
2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors Pub Date : 2006-09-01 DOI: 10.1109/ISSMDBS.2006.360088
Corinne Mattmann, Gerhard Tröster
{"title":"Design Concept of Clothing Recognizing Back Postures","authors":"Corinne Mattmann, Gerhard Tröster","doi":"10.1109/ISSMDBS.2006.360088","DOIUrl":"https://doi.org/10.1109/ISSMDBS.2006.360088","url":null,"abstract":"Continuous observation of the back enables an online feedback concerning malpositions or unhealthy movements. In this paper a design concept of clothing measuring back postures is presented. The posture detection is based on elongation measurements captured by strain sensitive fibres attached to the undershirt. The feasibility of this approach is shown by reference measurements, which provide a basis to define requirements for textile strain sensors. With these reference measurements, elongations in the range of 20% were measured on the back. The paper is completed by an overview of the state-of-the-art of potential technologies necessary for the proposed design.","PeriodicalId":409380,"journal":{"name":"2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2006-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"134441667","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 13
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信