电网技术最新文献

筛选
英文 中文
A chance-constrained programming approach to determine requirement of optimal spinning reserve capacity 一种确定最优旋转备用容量需求的机会约束规划方法
Power system technology Pub Date : 2006-01-01 DOI: 10.13335/J.1000-3673.PST.2006.20.004
Lu Wang, C. Yu, F. Wen
{"title":"A chance-constrained programming approach to determine requirement of optimal spinning reserve capacity","authors":"Lu Wang, C. Yu, F. Wen","doi":"10.13335/J.1000-3673.PST.2006.20.004","DOIUrl":"https://doi.org/10.13335/J.1000-3673.PST.2006.20.004","url":null,"abstract":"Under the premise of chance-constrained programming,when the consideration to reliability and economy of system operation should be given,how to consider the uncertainty factors such as the fault outage of generators and the error of load forecasting is researched so as to determine the optimal spinning reserve capacity that power system requires.Taking the purchase cost of minimized spinning reserve as objective as well as the secure requirement of power system as chance-constraint,a mathematical model to determine optimal spinning reserve capacity required by power system is constructed,and Monte Carlo simulation based genetic algorithm is adopted to solve the constructed model.Taking a power system containing 18 generating units for example the proposed model is illustrated.","PeriodicalId":20420,"journal":{"name":"Power system technology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66319849","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 21
Impacts of different numbers of bidding blocks on generation companies’ bidding strategies 不同竞价块数对发电公司竞价策略的影响
Power system technology Pub Date : 2006-01-01 DOI: 10.13335/J.1000-3673.PST.2006.19.006
Lu Wang, F. Wen, C. Yu
{"title":"Impacts of different numbers of bidding blocks on generation companies’ bidding strategies","authors":"Lu Wang, F. Wen, C. Yu","doi":"10.13335/J.1000-3673.PST.2006.19.006","DOIUrl":"https://doi.org/10.13335/J.1000-3673.PST.2006.19.006","url":null,"abstract":"In view of stepwise bidding protocol that is commonly adopted in practical operated electricity market home and abroad,the impacts of different numbers of bidding blocks on the bidding strategies of generation companies are investigated.As a preliminary research,here,the generation companies,which act as price-taker,are taken as subject investigated.Firstly,the electricity price in the market is simulated by probabilistic methods,on this basis and by use of average probability of wins a multi-block bidding model that simulate optimal bidding strategy of generation company is built.Then,the impacts of both generation company's risk preference extent and market information asymmetry on the construction of generation company's optimal bidding strategy are researched.Finally,a numerical example is used to demonstrate the proposed model and method,with special emphasis on the impacts of different numbers of bidding blocks on the optimal bidding strategy of generation companies.","PeriodicalId":20420,"journal":{"name":"Power system technology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2006-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66320216","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Study of the transient current differential protection based on correlation analysis 基于相关分析的暂态电流差动保护研究
Power system technology Pub Date : 2002-10-06 DOI: 10.1109/TDC.2002.1177583
Li Yan, Cheng De-shu, Yuan Rong-xiang, Yin Xiang-Geri, Zhang Zhe
{"title":"Study of the transient current differential protection based on correlation analysis","authors":"Li Yan, Cheng De-shu, Yuan Rong-xiang, Yin Xiang-Geri, Zhang Zhe","doi":"10.1109/TDC.2002.1177583","DOIUrl":"https://doi.org/10.1109/TDC.2002.1177583","url":null,"abstract":"In this paper, the principle of the current correlation differential protection based on the correlation integration is analyzed first. The advantages of the correlation differential criterion are proved and the disadvantages are also pointed out. Aiming to the disadvantages of the correlation criterion, an improved scheme was proposed in the paper. The power system models of different structures using ATP program are built to simulate these criterion completely. Simulation studies show that the improved scheme not only preserves the advantages of correlation criterion, but also increases many new virtues such as better sensitivity and reliability, simple to understand, easy to give out setting values. Studies also show that the improved scheme is more reliable and very suitable for the protection of EHV/UHV transmission lines.","PeriodicalId":20420,"journal":{"name":"Power system technology","volume":"2 1","pages":"830-834 vol.2"},"PeriodicalIF":0.0,"publicationDate":"2002-10-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/TDC.2002.1177583","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"62841556","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 5
A NEW LOAD SHEDDING SCHEME FOR LIMITING UNDERFREQUENCY 一种限制低频的新型减载方案
Power system technology Pub Date : 2001-01-01 DOI: 10.1016/0967-0661(94)91795-7
Pan Zhen
{"title":"A NEW LOAD SHEDDING SCHEME FOR LIMITING UNDERFREQUENCY","authors":"Pan Zhen","doi":"10.1016/0967-0661(94)91795-7","DOIUrl":"https://doi.org/10.1016/0967-0661(94)91795-7","url":null,"abstract":"","PeriodicalId":20420,"journal":{"name":"Power system technology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0967-0661(94)91795-7","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"53912884","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
A new method for improving flashover and leakage characteristics of line insulators 一种改善线路绝缘子闪络和漏电特性的新方法
Power system technology Pub Date : 2001-01-01 DOI: 10.13335/J.1000-3673.PST.2001.10.016
Xian-dong Li, Zhiyuan Li, J. Chen, Y. Wang, G. Zhang, J. MacAlpine
{"title":"A new method for improving flashover and leakage characteristics of line insulators","authors":"Xian-dong Li, Zhiyuan Li, J. Chen, Y. Wang, G. Zhang, J. MacAlpine","doi":"10.13335/J.1000-3673.PST.2001.10.016","DOIUrl":"https://doi.org/10.13335/J.1000-3673.PST.2001.10.016","url":null,"abstract":"In this paper a new method is described in which an annular metal sheet coated with silicone rubber is added at the base of the conventional insul ator cap to improve the insulator unit's performance under both clean and pollut ed conditions. The annular metal sheet is connected to the insulator iron cap an d makes the electric field distribution more uniform, which increases the corona onset voltage. The annular metal sheet also makes the electric field direction on the insulator upper surface approximately perpendicular to the insulator surf ace, rather than parallel, as on the conventional insulator, therefore the devel opment of the discharge is restrained. At same time, the annular coated with sil icon rubber which possesses good pollution-proof performance can increase the c r eepage distance, reduce leakage current and raise the flashover voltage. The exp erimental results obtained coincide with the results of theoretical analyses. Th e fine performance of novel insulator is approved. After fully immersing the nov el insulator into the sodium chloride solution at density of 10g/l, its flashov er voltage is multiplied, the corona onset voltage increased more than 70% and t he leakage current decreased nearly 30% under the same polluted conditions.","PeriodicalId":20420,"journal":{"name":"Power system technology","volume":"1 1","pages":""},"PeriodicalIF":0.0,"publicationDate":"2001-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"66320159","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信