IEEE Nuclear Science Symposuim & Medical Imaging Conference最新文献

筛选
英文 中文
Configurable digital multi-channel processing for emulation and elaboration of radiation events 可配置的数字多通道处理,用于模拟和阐述辐射事件
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5873734
A. Abba, A. Geraci
{"title":"Configurable digital multi-channel processing for emulation and elaboration of radiation events","authors":"A. Abba, A. Geraci","doi":"10.1109/NSSMIC.2010.5873734","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5873734","url":null,"abstract":"We present a digital fully configurable architecture that performs the function of signal generation for emulation of radiation detectors and front-end electronics and the function of processor of signals from radiation detectors. The proposed architecture has been conceived to serve as a general purpose investigation instrument in digital spectroscopy applications, both at hardware and firmware level. It allows the emulation of all parts of an acquisition and processing setup and consequently implements a real and complete hardware and firmware co-design platform. The system has been prototyped and is being fully tested.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"1 1","pages":"145-152"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"87350025","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
Crystal growth and Scintillation properties of AGd2Cl7:Ce3+ (A = Cs, K) for gamma and neutron detection 用于伽马和中子探测的AGd2Cl7:Ce3+ (A = Cs, K)晶体生长和闪烁特性
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5873978
Kan Yang, M. Zhuravleva, H. Rothfuss, C. Melcher
{"title":"Crystal growth and Scintillation properties of AGd2Cl7:Ce3+ (A = Cs, K) for gamma and neutron detection","authors":"Kan Yang, M. Zhuravleva, H. Rothfuss, C. Melcher","doi":"10.1109/NSSMIC.2010.5873978","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5873978","url":null,"abstract":"A new family of Ce-containing scintillator materials is introduced. In this work, we report on the crystal growth of KGd<inf>2</inf>Cl<inf>7</inf>:Ce and CsGd<inf>2</inf>Cl<inf>7</inf>:Ce via the Vertical Gradient Freeze method. Various Ce concentrations from 0.5 to 10 at% have been tested to study the effect of dopant concentration on scintillation performance. Both KGd<inf>2</inf>Cl<inf>7</inf>:Ce and CsGd<inf>2</inf>Cl<inf>7</inf>:Ce have demonstrated good properties for gamma ray and thermal neutron detection. Scintillation light yield was ∼30,000 ph/MeV for KGd<inf>2</inf>Cl<inf>7</inf>: 3% Ce and ∼38,000 ph/MeV for CsGd<inf>2</inf>Cl<inf>7</inf>: 3% Ce. The crystals exhibited layered structure with cleavage planes.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"59 1","pages":"1300-1303"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90627839","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Thermal neutron imaging tests using Ce doped LiCaAlF6 and sealed 252Cf source 采用Ce掺杂LiCaAlF6和密封252Cf源进行热中子成像测试
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5874560
N. Kawaguchi, T. Yanagida, Y. Fujimoto, Y. Yokota, K. Kamada, K. Fukuda, T. Suyama, Kenichi Watanabe, A. Yamazaki, A. Yoshikawa
{"title":"Thermal neutron imaging tests using Ce doped LiCaAlF6 and sealed 252Cf source","authors":"N. Kawaguchi, T. Yanagida, Y. Fujimoto, Y. Yokota, K. Kamada, K. Fukuda, T. Suyama, Kenichi Watanabe, A. Yamazaki, A. Yoshikawa","doi":"10.1109/NSSMIC.2010.5874560","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5874560","url":null,"abstract":"Thermal neutron imaging with Ce doped <sup>6</sup>LiCaAlF<inf>6</inf>, which is a novel thermal neutron scintillator, was demonstrated. Ce doped <sup>6</sup>LiCaAlF<inf>6</inf> single crystal was grown by Czochralski technique and grown crystal was cut and polished to a plate shape. Setup of the thermal neutron imaging consisted of the plate shaped Ce doped <sup>6</sup>LiCaAlF<inf>6</inf>, a position sensitive photomultiplier tube, alphabet-shaped Cd-masks and <sup>252</sup>Cf in the polyethylene container. As a result, clear neutron image was successfully observed.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"6 1","pages":"3968-3970"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"88166719","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Optimization of a mixed multiplicity counter using Monte Carlo simulations and measurements 使用蒙特卡罗模拟和测量的混合多重计数器的优化
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5873964
A. Enqvist, K. Weinfurther, M. Flaska, S. Pozzi
{"title":"Optimization of a mixed multiplicity counter using Monte Carlo simulations and measurements","authors":"A. Enqvist, K. Weinfurther, M. Flaska, S. Pozzi","doi":"10.1109/NSSMIC.2010.5873964","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5873964","url":null,"abstract":"A measurement system capable of multiplicity measurements for both neutrons and gamma rays has been developed at the University of Michigan. The benefit of such an approach is in the increased number of available measurables. A pure neutron assay results in three measurables for third-order multiples, while a combined neutron/gamma-ray assay results in 9 measurables for the same order of multiples. The idea is to use the additional measurables to achieve greater accuracy when determining unknown parameters of the sample such as the fissile mass. The measurement system is based on liquid scintillation detectors (EJ-309) which feed detected pulses to a digital data-acquisition system. The excellent pulse shape discrimination capabilities of the EJ-309s allow for accurate differentiation between gamma-ray pulses and neutron pulses. The PSD is vital to correctly identify the different multiples up to the third order: n, γ, nn, nγ, γγ, nnn, nnγ, nγγ and γγγ. Previous investigation of the measurement system showed that good counting statistics can be achieved within minutes for spontaneous-fission sources such as 252Cf. In this paper, we present new measurement results and corresponding Monte Carlo simulations aimed at charaterizing the measurement system. Comparison of the measured and simulated multiples count rates is discussed in detailed and a relatively good agreement on trends and count rates is found.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"1 1","pages":"1232-1238"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91208104","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Hardware setup for the next generation of 3D Ultrasound Computer Tomography 下一代三维超声计算机断层扫描的硬件设置
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5874228
H. Gemmeke, L. Berger, M. Birk, Georg Göbel, A. Menshikov, D. Tcherniakhovski, M. Zapf, N. Ruiter
{"title":"Hardware setup for the next generation of 3D Ultrasound Computer Tomography","authors":"H. Gemmeke, L. Berger, M. Birk, Georg Göbel, A. Menshikov, D. Tcherniakhovski, M. Zapf, N. Ruiter","doi":"10.1109/NSSMIC.2010.5874228","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5874228","url":null,"abstract":"We describe the second generation of a 3D-Ultrasound Computer Tomography (USCT) system. After we achieved in the first generation a device with sub-wavelength resolution and three imaging modalities (reflection, attenuation, speed of sound) and tested it with static phantoms, we developed a device for in-vivo imaging. In the new system the geometry of transducers and their spatial distribution is optimized in respect to uniformity and high value of: contrast, resolution, and illumination. Furthermore we developed new electronics which allows faster DAQ (≤ 2 min) and contains larger and faster FPGAs to use their processing power for data pre-processing.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"73 1","pages":"2449-2454"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"91248034","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 24
An intelligent HV control and monitoring system for the PHENIX Hadron Blind Detector at the relativistic heavy ion collider 相对论重离子对撞机PHENIX强子盲探测器的智能高压控制与监测系统
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5873884
M. Proissl, B. Azmoun, S. Boose, M. Durham, T. Hemmick, A. Milov, S. Polizzo, M. Purschke, C. Woody
{"title":"An intelligent HV control and monitoring system for the PHENIX Hadron Blind Detector at the relativistic heavy ion collider","authors":"M. Proissl, B. Azmoun, S. Boose, M. Durham, T. Hemmick, A. Milov, S. Polizzo, M. Purschke, C. Woody","doi":"10.1109/NSSMIC.2010.5873884","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5873884","url":null,"abstract":"The PHENIX Hadron Blind Detector (HBD) is a high-performance Cherenkov counter used to detect electrons in relativistic heavy ion collisions at RHIC. A High Voltage Control and Monitoring System (HVC) was developed to provide optimal control over the detector for maximal performance and protection against damage from possible discharges. The HVC comprises several novel hardware components including a voltage divider board and trip detection/protection boards for each power supply module, while actual control of the HV is maintained by a software suite which incorporates Modern Optimal Control Theory and Artificial Intelligence concepts. The software suite is made up of several concurrently operating subsystems, which periodically processes measurements fed back from the HV mainframe, the HBD gas pressure (P) and temperature (T) sensors, analyzes the GEM module behavior in reference to its performance over time, determines a custom response and modifies the HV when necessary. Since the HBD gain is very sensitive to P/T fluctuations, the HVC automatically modifies the GEM/Mesh voltage accordingly in order to keep the gain variations within a nominal operating range of +/− 10%. Both hardware and software components of the HVC will be described, along with the successful performance results throughout the commissioning p+p Run-9 and the HBD's final and most important Au+Au Run-10.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"23 1","pages":"865-870"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89508395","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Cosmic ray muon tomography system using drift chambers for the detection of Special Nuclear Materials 用漂移室探测特殊核材料的宇宙射线介子层析成像系统
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5873821
V. Anghel, J. Armitage, J. Botte, K. Boudjemline, D. Bryman, E. Charles, T. Cousins, A. Erlandson, G. Gallant, C. Jewett, G. Jonkmans, Z. Liu, S. Noel, G. Oakham, T. Stocki, M. Thompson, D. Waller
{"title":"Cosmic ray muon tomography system using drift chambers for the detection of Special Nuclear Materials","authors":"V. Anghel, J. Armitage, J. Botte, K. Boudjemline, D. Bryman, E. Charles, T. Cousins, A. Erlandson, G. Gallant, C. Jewett, G. Jonkmans, Z. Liu, S. Noel, G. Oakham, T. Stocki, M. Thompson, D. Waller","doi":"10.1109/NSSMIC.2010.5873821","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5873821","url":null,"abstract":"The smuggling of illicit Special Nuclear Materials (SNM) and Radiological Materials (RM) is a major security concern. Current radiation detection systems for cargo are not sensitive to well-shielded nuclear materials. The Muon Scattering Tomography (MST) method that we are developing might be a solution to this problem. It is based on the measurement of multiple scattering of cosmic ray-induced muons, traversing high-Z materials such as uranium and plutonium. This is possible due to the muons' highly penetrating nature. The technique involves measuring the angular deflections of these muons with charged particle tracking detectors placed around the object to be probed. One candidate detector is the single wire drift chamber. It can measure the 2-D impact position of a muon. The CRIPT (Cosmic Ray Inspection and Passive Tomography) collaboration has performed computer simulations of detectors designed to detect SNM via MST. We have also worked on the development of image reconstruction algorithms, and simulated the performances of different muon spectrometer designs and the response of the drift chambers. In addition to these efforts, the collaboration has built three prototypes which are being tested.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"21 1","pages":"547-551"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89990176","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 16
Detection and track visualization of primary and secondary radiation in hadron therapy beams with the pixel detector Timepix 用像素探测器Timepix检测强子治疗光束的一次和二次辐射并跟踪可视化
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5874118
J. Jakubek, C. Granja, O. Jakel, M. Martišíková, Stanislav Pospicil
{"title":"Detection and track visualization of primary and secondary radiation in hadron therapy beams with the pixel detector Timepix","authors":"J. Jakubek, C. Granja, O. Jakel, M. Martišíková, Stanislav Pospicil","doi":"10.1109/NSSMIC.2010.5874118","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5874118","url":null,"abstract":"The interaction of proton and hadron beams of relativistic energy in matter is accompanied by the production of penetrating highly energetic secondary particles and nuclear reaction products which can affect the desired highly localized deposition of energy of the primary high LET particles for radiotherapy purposes. The observation of all ionizing particles arising from and accompanying the primary radiation as well as the direct measurement of particle energy loss, trajectory, local energy deposition and lateral straggling can be directly provided by the semiconductor pixel detector Timepix. This device operates as an active nuclear emulsion providing on-line visualization of particle traces. Results of a pilot experiment are presented with proton and carbon ion beams in the energy range 48–220 MeV/u and 88–430 MeV, respectively produced at the Heavy Ion Therapy HIT facility in Heidelberg.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"16 1","pages":"1967-1969"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90008408","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 20
PMT- cross-display scintillator block detector design and Monte Carlo study PMT-交叉显示闪烁块探测器的设计与蒙特卡罗研究
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5874217
Qingyang Wei, Yaqiang Liu, Tianyu Ma, Yan Xia, Shi Wang, Zhaoxia Wu, Yongjie Jin
{"title":"PMT- cross-display scintillator block detector design and Monte Carlo study","authors":"Qingyang Wei, Yaqiang Liu, Tianyu Ma, Yan Xia, Shi Wang, Zhaoxia Wu, Yongjie Jin","doi":"10.1109/NSSMIC.2010.5874217","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5874217","url":null,"abstract":"Block detector using crystals coupled to circular photomultipliers (PMTs) is commonly used in positron emission tomography (PET). We design a novel PET block detector with cross-shape PMT layout (CSPL). The block detector consists of 9×9 lutetium orthosilicate (LSO) pixelated crystal array (2.2mm×2.2mm×10mm) and five PMTs (four 3/4 inch with circular envelope, one 3/8 inch with square envelope) arranging in a cross-shape layout with the small one in the middle. The crystals are separated by Teflon reflectors and optical grease to control the light distribution. Monte Carlo simulation package GATE is used to simulate the processes of both gamma ray interaction and light spread in LSO crystals. Impact of major resolution limiting parameters, including inter-crystal scattering, parallax effect and light spread in the crystals on the performance of the proposed detector design is investigated. Simulation results show that the proposed block detector design could get higher light collection and better position profile.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"11 1","pages":"2400-2402"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"90867802","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 2
Task based assessment of cardiac function in Monte Carlo simulated gated Tl-201 perfusion SPECT: A human observer study 基于任务的蒙特卡罗模拟门控Tl-201灌注SPECT心功能评估:一项人类观察研究
IEEE Nuclear Science Symposuim & Medical Imaging Conference Pub Date : 2010-10-01 DOI: 10.1109/NSSMIC.2010.5874341
P. Pretorius, J. M. O'Connor, R. Licho, J. Brankov
{"title":"Task based assessment of cardiac function in Monte Carlo simulated gated Tl-201 perfusion SPECT: A human observer study","authors":"P. Pretorius, J. M. O'Connor, R. Licho, J. Brankov","doi":"10.1109/NSSMIC.2010.5874341","DOIUrl":"https://doi.org/10.1109/NSSMIC.2010.5874341","url":null,"abstract":"Different implementations of the receiver operator characteristic (ROC) method in cardiac perfusion SPECT have been described. However, none has attempted to independently assess cardiac function. The aim of this study was, therefore, to design and execute a human observer ROC study that includes the evaluation of cardiac function and perfusion. Due to the lack of a gold standard, our initial design used an improved Mathematical Cardiac Torso (MCAT) phantom to generate normal and abnormal regional function. Abnormal heart function included hypokinesis, akinesis, and dyskinesis. Two heart sizes (124 ml and 100 ml left ventricular cavities) were used for male and female patients, respectively. Eight different locations around the LV myocardium were selected and perfusion defects of various sizes generated. Sixteen gated hearts across the cardiac cycle with abnormal cardiac function according to the different motion models were generated. The SIMIND Monte Carlo package was used to simulate a clinical Tl-201 perfusion SPECT acquisition protocol on the 3-headed IRIX gamma camera (Philips Medical Systems, Cleveland, Ohio). Data were reconstructed using the rescaled block iterative (RBI) technique with 17 subsets (4 projections/subset) and 5 iterations. Three sets of sixty-five cases were shown to an observer, the first 10 cases were used as training while the remainder (55 cases) were read and scored. The readings of the total 165 observed cases served as input data for ROC curve generation. The observer read the data in two ways. In the first reading the observer gave a confidence rating for regional myocardial function followed by a separate confidence rating for a perfusion defect. In the second reading, the order was reversed. ROC curves and areas under curve (AUCs) were determined separately for each reading approach. ROCs and AUCs were calculated for the three coronary artery territories as well as an overall calculation for the heart. While several ideas to further improve the methodology were generated during this study, we believe that we have clearly demonstrated that one can perform an independent quantitative task based assessment of cardiac function.","PeriodicalId":13048,"journal":{"name":"IEEE Nuclear Science Symposuim & Medical Imaging Conference","volume":"1 1","pages":"2972-2976"},"PeriodicalIF":0.0,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"89617212","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 1
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信