JURNAL TECHLINK最新文献

筛选
英文 中文
EFISIENSI PENURUNAN KADAR BOD DAN TSS DENGAN BAKTERI KULTUR EM4 PADA AIR LIMBAH RUMAH SAKIT DENGAN SISTEM AERASI BOD和TSS的效率降低,在医院废水中带有EM4培养细菌
JURNAL TECHLINK Pub Date : 2023-01-06 DOI: 10.59134/jtnk.v6i02.177
Eksa Agung Utomo, Nurhayati, Benjamin Lekatompessy
{"title":"EFISIENSI PENURUNAN KADAR BOD DAN TSS DENGAN BAKTERI KULTUR EM4 PADA AIR LIMBAH RUMAH SAKIT DENGAN SISTEM AERASI","authors":"Eksa Agung Utomo, Nurhayati, Benjamin Lekatompessy","doi":"10.59134/jtnk.v6i02.177","DOIUrl":"https://doi.org/10.59134/jtnk.v6i02.177","url":null,"abstract":"Water is an important resource for human life and other living things, and is also a valuable capital investment. Water quality is a problem because of the large amount of waste generated by human activities. This waste includes things like wastewater from households, factories, and other activities. Therefore, an effective micro-organism-4 (em4) is needed to treat wastewater. The purpose of this study was to determine whether the use of EM4 can reduce the amount of pollutants in hospital waste. The research method used is a laboratory experimental method used to study the effect of the variables studied. Experiment using the formula . The results of this study show the effectiveness of pollution levels using EM4 culture with a time of 16 days with the highest efficiency value found on day 16 in each parameter. Treatment on day 0 shows BOD 20.035 mg/L until treatment on day 16 results in BOD value of 6.087 mg/L and the second repetition (Y2) treatment on day 0 shows BOD value of 20.022 mg/L until treatment on day 16 BOD value is 5.022mg/L. It shows that the mean (Mean) BOD decreased from the initial concentration of 20.029 at 0 days to 5.555 at 16 days treatment. On the 16th day the efficiency value of setting aside BOD levels is 72.3%, on day 0 the TSS result is 85 mg/L until the repetition (Y1) on the 16th day the BOD result becomes 28 mg.L and the second repetition (Y2) on day 0 TSS result 83 mg/L until repetition (Y2) on day 16 the result TSS value 26 mg/L. Then the mean value (Mean) of TSS decreased from the initial concentration of TSS value of 84 mg/L on treatment day 0 and became 27 mg/L. on 16 days of treatment while for TSS levels that is equal to 67.86%.","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"70 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"127127141","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PENGARUH RELOKASI PEMUKIMAN KUMUH TERHADAP KUALITAS KESEHATAN LINGKUNGAN (STUDI KASUS KAMPUNG PULO JAKARTA TIMUR) 贫民窟安置对环境健康质量的影响(雅加达东部村庄案例研究)
JURNAL TECHLINK Pub Date : 2023-01-06 DOI: 10.59134/jtnk.v6i02.171
Irma Octalita Manurung, Charles Situmorang
{"title":"PENGARUH RELOKASI PEMUKIMAN KUMUH TERHADAP KUALITAS KESEHATAN LINGKUNGAN (STUDI KASUS KAMPUNG PULO JAKARTA TIMUR)","authors":"Irma Octalita Manurung, Charles Situmorang","doi":"10.59134/jtnk.v6i02.171","DOIUrl":"https://doi.org/10.59134/jtnk.v6i02.171","url":null,"abstract":"This study aims to determine the effect of slum relocation on environmental health quality (case study of Kampung Pulo, East Jakarta). The research method used is a survey with a quantitative approach. Data were analyzed using correlation and simple linear regression. This research was conducted on residents of Kampung Pulo slum relocation who were moved to West Jatinegara flats, East Jakarta, DKI Jakarta Province. This research was conducted from January to June 2022. The population of this study is 125 people of Kampung Pulo who were relocated to the West Jatinegara flats, East Jakarta. The sampling technique used is non-probability sampling, which is incidental sampling. The number of samples in this study using the Slovin formula of 95 Kampung Pulo people who were relocated to the West Jatinegara flats, East Jakarta. The results showed that the analysis obtained the regression equation = 32.185 + 0.603 X interpreted that every change in the Slum Settlement Relocation variable score (X) was 1 point, it can be estimated that the Environmental Health Quality score (Y) would change by 0.603 in the same direction with a constant of 32,185. The results of the t-test for tcount of 7.068 are greater than ttable (95) of 1.661 at = 0.05. The significance value (sig.) of 0.000 is smaller than = 0.05. This means that there is a positive (7.068) and significant (0.000) effect between Slum Relocation (X) on Environmental Health Quality (Y). The conclusion of the t test results is that there is a significant positive effect between Slum Relocation (X) on Environmental Health Quality(Y). This means that the more the relocation of slums to the West Jatinegara flats, East Jakarta, DKI Jakarta Province, the quality of environmental health will also increase. The correlation coefficient of the effect of Slum Settlement Relocation (X) on Environmental Health Quality (Y) (R) of 0.591 is included in the category of moderate relationship (Table 3.3: Medium = 0.40 – 0.599). The coefficient of determination is obtained from the R square value of 0.349. So 34.9% of the variance in Environmental Health Quality (Y) can be explained by the Slum Settlement Relocation variable (X). The remaining 65.1% is influenced by other variables outside the research, such as environmental sanitation, clean and healthy living behavior (PHBS), clean living attitudes and so on. Based on the results ofhypothesis testing, research findings show that there is a significant positive effect between Slum Settlement Relocation (X) on Environmental Health Quality (Y). Thus, the conclusion of the study is that the more the relocation of slums to the West Jatinegara rusunawa, East Jakarta, DKI Jakarta Province, the quality of environmental health will also increase","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"37 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130769210","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PERANCANGAN SISTEM PLAMBING PADA BANGUNAN WISMA MESS SEPOLWAN CIPUTAT
JURNAL TECHLINK Pub Date : 2023-01-06 DOI: 10.59134/jtnk.v6i02.176
Ayo Pahpayungi, Hening Darpito, Mudarisin
{"title":"PERANCANGAN SISTEM PLAMBING PADA BANGUNAN WISMA MESS SEPOLWAN CIPUTAT","authors":"Ayo Pahpayungi, Hening Darpito, Mudarisin","doi":"10.59134/jtnk.v6i02.176","DOIUrl":"https://doi.org/10.59134/jtnk.v6i02.176","url":null,"abstract":"The construction of high-rise buildings in big cities is currently increasing rapidly, before the building is built, it is necessary to plan a plumbing system to meet the needs of water supply for daily needs in buildings and waste water disposal. In planning the plumbing of Wisma Mess Sepolwan 3 floors, the need for clean water is 28.92 m3/day, the GWT (Ground Water Tank) bottom tank capacity is 6.5 m3/day, the top tank capacity (Roof Tank) is 5.4 m3/day and the sewer tank 25 m3/day.The transfer of clean water from the ground water tank to the top water tank (roof tank) uses a transfer pump with a capacity of 5.4 m3/minute, pump head of 39.64 m. Fordistribution of clean water on 3 floors using a pressure booster pump with a capacity of 0.16 m3/minute and a pump head of 10.3 m.Transfer of clean water from the bottom water tank (Ground Water Tank) to the top water tank (Roof Tank) using a pipe size of 40 mm. The design of the diameter of the clean water distribution pipe for each floor gets a size of 150 mm diameter of the main pipe / water main pipe and 50 mm per floor.The design of the diameter of the sewerage pipe from (closet and toilet) size to the standpipe for each floor is 100 mm and the diameter of the riser standpipe is 150 mm. The design of the diameter of the waste water pipe from (hand sinks and traps) to the size of the standpipe for each floor is 80 mm and the diameter of the riser standpipe is 100 mm. The design of the vent pipe diameter for the size of the standpipe for each floor is 50 mm and the diameter of the riser standpipe is 80 mm","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2023-01-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128205186","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
ANALISA RISIKO KECELAKAAN KERJA DENGAN MENGGUNAKAN METODE FMEA (FAILURE MODE AND EFFECT ANALYSIS)
JURNAL TECHLINK Pub Date : 2022-03-19 DOI: 10.59134/jtnk.v4i1.62
Fari Fatullah
{"title":"ANALISA RISIKO KECELAKAAN KERJA DENGAN MENGGUNAKAN METODE FMEA (FAILURE MODE AND EFFECT ANALYSIS)","authors":"Fari Fatullah","doi":"10.59134/jtnk.v4i1.62","DOIUrl":"https://doi.org/10.59134/jtnk.v4i1.62","url":null,"abstract":"The purpose of the study was to analyze the risk of work accidents using the FMEA (Failure Mode and Effect Analysis) method at the Bukit Tua ORF project at PT Raga Perkasa Ekaguna, Madura in 2018. The study used a descriptive method with a qualitative approach. The results showed the ranking of severity scale, failure mode with the highest scale with a value of 10 is the object falling on the lifting by crane activity and on the type of accident the collapsing excavation wall fell upon workers on the activity. The smallest severity scale of failure mode is exposed to UV rays for a long time with a scale of 2. The occurance scale, the highest cause of failure mode is a sling or broken steel rope with a value of 7 in lifting by crane activities. As for the occurance scale, the lowest cause of failure mode is the distance between workers too close to the value of 1 on the activities of road, drainage, foundation. The highest scale of detection, cause of failure mode is to ensure the condition of the equipment before work begins with a value of 7 in lifting by crane activities. The lowest detection scale is the distance between workers too close to the value 1. The highest RPN calculation result is the lifting by crane activity that causes the object to fall, with an RPN value of 490. Improvement of Fishbone diagram results, to humans or workers by providing training on hazards caused by lifting by crane activities, the chief coordinator or supervisor is expected to always supervise the performance of his subordinates. Machines, by conducting routine checks on each of the tools used in crane lifting activities. Regular company checks can schedule regular repairs to these tools. The method, by making SOPs and lifting plans correctly that is by using the right calculations, can be done by coming directly to the work area and doing simulations using cranes that will be used as well as seeing the material to be raised in this activity. So that the data obtained to make SOP and or lifting plan are accurate so that it gets a precise calculation. Environment, by installing barriers or prohibited signs to pass, so that no unauthorized person enters the area during the appointment. Check the condition of the soil so that it remains stable in the lifting area by the crane.","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"22 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"130554852","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
VALIDASI METODE UJI SENYAWA CYCLOHEXANE DI UDARA LINGKUNGAN KERJA DENGAN BERBAGAI MODIFIKASI METODE SECARA GAS CHROMATOGRAPHY MASS SPECTROMETRY 检验工作环境中周期性化合物的方法与气体色谱谱的不同改进
JURNAL TECHLINK Pub Date : 2022-03-19 DOI: 10.59134/jtnk.v4i1.65
Mochamad Rodjulun Kaffah
{"title":"VALIDASI METODE UJI SENYAWA CYCLOHEXANE DI UDARA LINGKUNGAN KERJA DENGAN BERBAGAI MODIFIKASI METODE SECARA GAS CHROMATOGRAPHY MASS SPECTROMETRY","authors":"Mochamad Rodjulun Kaffah","doi":"10.59134/jtnk.v4i1.65","DOIUrl":"https://doi.org/10.59134/jtnk.v4i1.65","url":null,"abstract":"Determination of the cyclohexane compound used refers to the National Institute of Occupational Safety and Health (NIOSH) method number 1500. Validation of the determination of cyclohexane in air samples of the work environment needs to be done due to modifications between them in different columns, glass columns 3.0 mx 2-mm , 20% SP-2100 on 80/100 mesh Supelcoport becomes Rtx-5MS column, the injector temperature difference, column temperature, detector temperature, and the test material used is cyclohexane pa to cyclohexane for gas chromatography, differences in measurements using FID detectors to spectrometer detectors mass. This experiment aims to ensure the performance of the cyclohexane determination method in the air sample of PT UP's work environment by gas chromatography mass spectrometry (GCMS) in accordance with the accepted method requirements set by PT. Unilab Prime. If all parameters meet the acceptance requirements, then this method can be used for routine analysis. Validation parameters carried out include linearity test, instrument detection limit (LDI), quantitation limit (LK), precision,accuracy, and strength of the method (robustness) using gas spectrometer mass chromatography. Based on the experimental results obtained by the value of the correlation coefficient linearity test (r) of 0.9998,% SBR for the precision test of 1.64%,% recovery obtained range of 89.26% - 105.35%. The instrument detection limit value is 0,0003mg / mL, the quantization limit is 0.0010mg / mL. Testing the strength parameters of the method (Robustness) produces cyclohexane concentrations in accordance with the accepted requirements of the working range of cyclohexane 0.5000mg / mL. Based on the test results obtained the performance of the cyclohexane determination method that has undergone modification in a sample of working air environment by gas chromatography mass spectrometry (GCMS) in accordance with the requirements set by thecompany so that it can be used for routine analysis in the PT Unilab Perdana environmental laboratory.","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"43 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125091400","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PENGARUH STAPHYLOCOCCUS AUREUS DALAM RUANGAN TERHADAP SICK BUILDING SYNDROME (SBS) DI PT UNILAB PERDANA, JAKARTA SELATAN
JURNAL TECHLINK Pub Date : 2022-03-19 DOI: 10.59134/jtnk.v4i1.64
Hendro Wiguno, Nurhayati, Hening Darpito
{"title":"PENGARUH STAPHYLOCOCCUS AUREUS DALAM RUANGAN TERHADAP SICK BUILDING SYNDROME (SBS) DI PT UNILAB PERDANA, JAKARTA SELATAN","authors":"Hendro Wiguno, Nurhayati, Hening Darpito","doi":"10.59134/jtnk.v4i1.64","DOIUrl":"https://doi.org/10.59134/jtnk.v4i1.64","url":null,"abstract":"This study aims to obtain information and determine the effect of Staphylococcus aureus in the room against sick building syndrome (SBS) on front office employees and operational space at PT Unilab Perdana, South Jakarta. The location of the study was conducted at PT Unilab Perdana, South Jakarta. When the study was conducted in March to July 2019. The results showed that: the influence of SBS symptoms at the front office location were 44 people, an average of 9 colonies of staphylococcus aureus bacteria. While the influence of SBS symptoms in the operational space location was 64 people, with an average of 18.3 colonies of staphylococcus aureus bacteria. The number of employees in the operational room experienced a frequency of Sick Building Syndrome (SBS) complaints dominated by headaches, fatigue, difficulty concentrating and nausea and dizziness with a category 1-3 times as many as 8 people (53.33%). The cause of the number of employees who are in the operational room experiences the frequency of Sick Building Syndrome (SBS) complaints because of the large number of employees who are in the operational space location, and employee activities are centralized in the operational space. Thus, there is an effect of the number ofstaphylococcus aureus bacterial colonies in the room on Sick Building Syndrome (SBS) in front office employees and the operating room of PT Unilab Perdana, South Jakarta. The dominance of symptomsand frequency of Sick Building Syndrome (SBS) complaints occurred in employees in the operatingroom of PT Unilab Perdana, South Jakarta","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"84 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"123271210","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PEMANFAATAN LARVA LALAT BLACK SOLDIER FLY (Hermetia illucens) UNTUK PEMBUATAN PUPUK KOMPOS PADAT DAN PUPUK KOMPOS CAIR 使用黑兵蝇幼虫(Hermetia illucens)生产固体肥料和液体堆肥
JURNAL TECHLINK Pub Date : 2022-03-19 DOI: 10.59134/jtnk.v4i1.60
Prisilia Eka Kusumawati, Yusriani Sapta Dewi, Rofiq Sunaryanto
{"title":"PEMANFAATAN LARVA LALAT BLACK SOLDIER FLY (Hermetia illucens) UNTUK PEMBUATAN PUPUK KOMPOS PADAT DAN PUPUK KOMPOS CAIR","authors":"Prisilia Eka Kusumawati, Yusriani Sapta Dewi, Rofiq Sunaryanto","doi":"10.59134/jtnk.v4i1.60","DOIUrl":"https://doi.org/10.59134/jtnk.v4i1.60","url":null,"abstract":"Composting is a form of decomposing organic matter with the help of organisms for bioconversion. The composting process requires several requirements to produce good quality compost, namely water content, pH and nutrient availability which is reflected in the C / N ratio. One type of insect larvae that can be used as an element of organism is the Black Soldier Fly (BSF) insect. The effort to recycle organic waste involving Black Soldier Fly (BSF) insect larvae is a new paradigm in the management of organic waste as decomposers or decomposers of organic waste. The result of the conversion of organic waste into solid compost fertilizer has a moisture content value that exceeds quality standards, C-organic value and C / N ratio which is below the quality standard, has a basic pH, and macro nutrients (N + P2O5 + K2O) located in the Permentan quality standard No. 261 / KPTS / SR.30 / M /4/2019, while for liquid compost fertilizer the value of C-organic and macro nutrients (N + P2O5 + K2O) is in Permentan quality standard No.261 / KPTS / SR.30 / M / 4/2019.","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"8 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"124341458","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 4
PENGEMBANGAN METODE ANALISIS BENZENA, TOLUENA, DAN XYLENA DALAM UDARA LINGKUNGAN KERJA MENGGUNAKAN IN HOUSE METODE DI PT UNILAB PERDANA 在空气环境中采用的苯、托鲁埃纳和木质素分析方法的改进使用的是首次使用PT UNILAB的内部方法
JURNAL TECHLINK Pub Date : 2022-03-19 DOI: 10.59134/jtnk.v4i1.61
Rendi Maulana, Rofiq Sunaryanto, Charles Situmorang
{"title":"PENGEMBANGAN METODE ANALISIS BENZENA, TOLUENA, DAN XYLENA DALAM UDARA LINGKUNGAN KERJA MENGGUNAKAN IN HOUSE METODE DI PT UNILAB PERDANA","authors":"Rendi Maulana, Rofiq Sunaryanto, Charles Situmorang","doi":"10.59134/jtnk.v4i1.61","DOIUrl":"https://doi.org/10.59134/jtnk.v4i1.61","url":null,"abstract":"Benzene, Toluene and Xylene (BTX) compounds are compounds that have colorless and flammable characteristics, have a sweet odor with a low toxicity level, and are not soluble in water. This compound is often used as a solvent, extractor and as a chemical intermediary. The testing of BTX parameters in the working environment refers to the National Institute of Occupational Safety and Health (NIOSH) method number 1501. The method must be modified or developed in terms of equipment and instruments, due to looking at the condition of the materials and equipment in PT UP, i.e. using different columns, capillary columns, fused silica, 30m x 0.32-mm ID; 1-μm film 100% PEG becomes a Rtx-5MS column, and measurements using a FID detector become a Mass Spectrometer detector. And the solvent used is Carbon Disulfiida (CS2) to Methanol for gas chromatography. CS2 solvents are carcinogenic in the body so that they are harmful to human health. Besides being harmful to health, the waste produced by CS2 causes damage to the ozone layer on the earth's surface so that it can trigger global warming which will make the earth feel hot. In addition, CS2 solvents in Indonesia have begun to be reduced in production and will be illegal inthe future. Therefore, this method needs to be validated before doing a routine analysis so that the data obtained is valid.","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"32 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"125178412","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
PERBEDAAN TANAMAN MELATI AIR (Echinodorus paleafolius) DAN KIAMBANG (Salvinia natans) SEBAGAI FITOREMEDIASI DALAM PROSES PENGOLAHAN LIMBAH CAIR LAUNDRY 茉莉花(Echinodorus paleafolius)和kiport (Salvinia natans)的不同之处在于处理洗衣房污水的过程中
JURNAL TECHLINK Pub Date : 2022-03-19 DOI: 10.59134/jtnk.v4i1.63
Fitri Hidayah
{"title":"PERBEDAAN TANAMAN MELATI AIR (Echinodorus paleafolius) DAN KIAMBANG (Salvinia natans) SEBAGAI FITOREMEDIASI DALAM PROSES PENGOLAHAN LIMBAH CAIR LAUNDRY","authors":"Fitri Hidayah","doi":"10.59134/jtnk.v4i1.63","DOIUrl":"https://doi.org/10.59134/jtnk.v4i1.63","url":null,"abstract":"Laundry waste that is directly discharged into the environment can cause environmental pollution. Seeing this condition, of course it is necessary to strive for an environmental mitigation engineering system, so it is necessary to find an alternative treatment that is easy, inexpensive and effective in its application. The research aims to examine the ability of these aquatic plants to reduce phosphate, BOD, COD, TSS, temperature and pH content in laundry wastewater treatment using phytoremediation. The type of research used is experimental research that is to see the relationship between water jasmine and kiambang plants as phytoremediation in the process of laundry wastewater treatment. Data analysis using ANOVA analysis and different test. The results showed that there were significant differences in the parameters of BOD5, COD, TSS and Pospat (PO4) in water jasmine (Echinodorus paleafolius) and Kiambang (Salvinia natans) plants as phytoremediation in the laundry wastewater treatment process","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"113 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"131353414","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
Efektifitas Arang Tempurung Kelapa dalam Menurunkan Kadar Logam Perak dan Kromium pada Limbah Laboratorium 椰子壳炭在减少实验室废物中的银和铬水平方面的有效性
JURNAL TECHLINK Pub Date : 2022-03-18 DOI: 10.59134/jtnk.v3i1.57
Darma Putra Deni
{"title":"Efektifitas Arang Tempurung Kelapa dalam Menurunkan Kadar Logam Perak dan Kromium pada Limbah Laboratorium","authors":"Darma Putra Deni","doi":"10.59134/jtnk.v3i1.57","DOIUrl":"https://doi.org/10.59134/jtnk.v3i1.57","url":null,"abstract":"Laboratorium waste is one of the causes that can contaminate the environment. Heavy metal that can contaminate the environment such as silver metal (Ag) and Cromium metal should be removed.The purposefor this research is for remove silver metal (Ag) and Crom metal from the laboratorium waste.Method thatuse in this reasearch is completely randomized factorial.The result of this analysis is show that charcoalcoconut shell is very effective to reduce silver metal (Ag) 85,49 %; 89,27 %; 93,01 %; 96;71 % and Crommetal (Cr) 13,81 %; 24,73 %; 31,92 %; 38,60 % at the addition of Charcoal coconut shell 0,5 g;1,5 g; 2,5g; 3,5 g in laboratorium waste.Result of varian analysis show thatconfidence level F count > F table atthe 95 % and 99 % , it means that addition of charcoal coconut shell give the significant result for removalof silver metal and Crom meta","PeriodicalId":127483,"journal":{"name":"JURNAL TECHLINK","volume":"1 1","pages":"0"},"PeriodicalIF":0.0,"publicationDate":"2022-03-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":null,"resultStr":null,"platform":"Semanticscholar","paperid":"128005386","PeriodicalName":null,"FirstCategoryId":null,"ListUrlMain":null,"RegionNum":0,"RegionCategory":"","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":"","EPubDate":null,"PubModel":null,"JCR":null,"JCRName":null,"Score":null,"Total":0}
引用次数: 0
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
相关产品
×
本文献相关产品
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信