The effects of technical factors on the fractal dimension in different dental radiographic images.

IF 0.9 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Mehmet Amuk, Gamze Sirin Saribal, Nihal Ersu, Serkan Yilmaz
{"title":"The effects of technical factors on the fractal dimension in different dental radiographic images.","authors":"Mehmet Amuk, Gamze Sirin Saribal, Nihal Ersu, Serkan Yilmaz","doi":"10.26650/eor.2023984422","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to assess the impact of exposure parameters and image formats on fractal dimension (FD) values in periapical, panoramic, and CBCT images.</p><p><strong>Materials and methods: </strong>Seven dry male mandibles were selected, and a Gutta-Percha was used to identify identical regions of interest. A periapical radiograph was taken with 60 kVp/7 mA and exported in DICOM, JPEG, TIFF, and PNG formats. Nine periapical radiographs (60, 65, 70 kVp; 4, 5, 6 mA) were taken from seven dry human mandibles. Additionally, 12 panoramic radiographs (60, 70, 81, 90 kVp; 5, 8, 13 mA) and 10 CBCT images (with different scanning options and FOVs) were taken from each mandible. FDs were measured from a standard area.</p><p><strong>Results: </strong>The intra-class correlation coefficient demonstrated a high degree of agreement between observers. No significant difference was found between TIFF and PNG formats (p > 0.05). The highest FD mean was found in TIFF format, while the lowest FD mean was found in JPEG format (p<0.001). There was no significant difference between kVp and mA settings in periapical images. In panoramic images, a significant difference was found at 90 kVp (p = 0.001) and 13 mA (p<0.001), with lower FD values observed at these settings. There was no significant difference between FOV and resolution in CBCT images (p > 0.05).</p><p><strong>Conclusion: </strong>The format of the image can influence FD. For periapical and panoramic radiographs, kVp and mA settings do not have a significant impact on FD. However, fractal analysis may not be an ideal method for evaluating three-dimensional images, such as those obtained with CBCT.</p>","PeriodicalId":41993,"journal":{"name":"European Oral Research","volume":null,"pages":null},"PeriodicalIF":0.9000,"publicationDate":"2023-05-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/60/34/eor-057-068.PMC10387138.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Oral Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26650/eor.2023984422","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study was to assess the impact of exposure parameters and image formats on fractal dimension (FD) values in periapical, panoramic, and CBCT images.

Materials and methods: Seven dry male mandibles were selected, and a Gutta-Percha was used to identify identical regions of interest. A periapical radiograph was taken with 60 kVp/7 mA and exported in DICOM, JPEG, TIFF, and PNG formats. Nine periapical radiographs (60, 65, 70 kVp; 4, 5, 6 mA) were taken from seven dry human mandibles. Additionally, 12 panoramic radiographs (60, 70, 81, 90 kVp; 5, 8, 13 mA) and 10 CBCT images (with different scanning options and FOVs) were taken from each mandible. FDs were measured from a standard area.

Results: The intra-class correlation coefficient demonstrated a high degree of agreement between observers. No significant difference was found between TIFF and PNG formats (p > 0.05). The highest FD mean was found in TIFF format, while the lowest FD mean was found in JPEG format (p<0.001). There was no significant difference between kVp and mA settings in periapical images. In panoramic images, a significant difference was found at 90 kVp (p = 0.001) and 13 mA (p<0.001), with lower FD values observed at these settings. There was no significant difference between FOV and resolution in CBCT images (p > 0.05).

Conclusion: The format of the image can influence FD. For periapical and panoramic radiographs, kVp and mA settings do not have a significant impact on FD. However, fractal analysis may not be an ideal method for evaluating three-dimensional images, such as those obtained with CBCT.

Abstract Image

Abstract Image

Abstract Image

技术因素对不同牙科放射影像分形维度的影响。
目的:本研究旨在评估曝光参数和图像格式对根尖周图像、全景图像和 CBCT 图像分形维度(FD)值的影响:选取 7 个干燥的男性下颌骨,用 Gutta-Percha 确定相同的感兴趣区。以 60 kVp/7 mA 的电压拍摄根尖周X光片,并导出为 DICOM、JPEG、TIFF 和 PNG 格式。九张根尖周X光片(60、65、70 kVp;4、5、6 mA)取自七个干燥的人类下颌骨。此外,每个下颌骨还拍摄了 12 张全景 X 光片(60、70、81、90 kVp;5、8、13 mA)和 10 张 CBCT 图像(采用不同的扫描选项和 FOV)。结果:类内相关系数显示观察者之间的一致性很高。TIFF 和 PNG 格式之间无明显差异(p > 0.05)。TIFF 格式的 FD 平均值最高,而 JPEG 格式的 FD 平均值最低(p 0.05):结论:图像格式会影响 FD。对于根尖周和全景 X 光片,kVp 和 mA 设置对 FD 的影响不大。不过,分形分析可能不是评估三维图像(如 CBCT 获得的图像)的理想方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
European Oral Research
European Oral Research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
1.60
自引率
0.00%
发文量
23
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信