Effect of aging and cementation systems on the bond strength to root dentin after fiber post cementation.

Q2 Medicine
Caio Henrique de Paula Nogueira, Mariana Bena Gelio, João Felipe Besegato, Anna Thereza Peroba Rezende Ramos, Eduardo Fernández, Milton Carlos Kuga, José Roberto Cury Saad
{"title":"Effect of aging and cementation systems on the bond strength to root dentin after fiber post cementation.","authors":"Caio Henrique de Paula Nogueira,&nbsp;Mariana Bena Gelio,&nbsp;João Felipe Besegato,&nbsp;Anna Thereza Peroba Rezende Ramos,&nbsp;Eduardo Fernández,&nbsp;Milton Carlos Kuga,&nbsp;José Roberto Cury Saad","doi":"10.1590/0103-6440202305082","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the effect of aging and cementation of fiber posts using glass ionomer and resin cements on push-out bond strength, failure mode, and resin tag formation. One hundred and twenty bovine incisors were used. After post-space preparation, the specimens were randomly allocated into 12 groups (n = 10) according to the cementation system used: GC - GC Gold Label Luting & Lining); RL - RelyX Luting 2; MC - MaxCem Elite; RU - RelyX U200 and the aging periods (24 hours, 6 months, and 12 months). Slices from the cervical, middle, and apical thirds were obtained and analyzed by push-out bond strength test and confocal laser scanning microscopy. One-way ANOVA and Tukey's post-hoc test was used at a significance level of 5%. For the push-out bond strength test, no differences among GC, RU, and MC in the cervical and middle thirds were observed, regardless of the period of storage (P > 0.05). In the apical third, GC and RU showed similar bond strength but higher than other groups (P > 0.05). After 12 months, GC showed the highest bond strength (P < 0.05). Bond strength to post-space dentin decreased over time, regardless of the cementation system used. Cohesive failure was the most frequent, regardless of the period of storage, cementation system, and post-space third. Tag formation was similar among all groups. After 12 months, GC showed the highest bond strength values.</p>","PeriodicalId":9211,"journal":{"name":"Brazilian dental journal","volume":"34 1","pages":"52-60"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10027095/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Brazilian dental journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/0103-6440202305082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

Abstract

This study evaluated the effect of aging and cementation of fiber posts using glass ionomer and resin cements on push-out bond strength, failure mode, and resin tag formation. One hundred and twenty bovine incisors were used. After post-space preparation, the specimens were randomly allocated into 12 groups (n = 10) according to the cementation system used: GC - GC Gold Label Luting & Lining); RL - RelyX Luting 2; MC - MaxCem Elite; RU - RelyX U200 and the aging periods (24 hours, 6 months, and 12 months). Slices from the cervical, middle, and apical thirds were obtained and analyzed by push-out bond strength test and confocal laser scanning microscopy. One-way ANOVA and Tukey's post-hoc test was used at a significance level of 5%. For the push-out bond strength test, no differences among GC, RU, and MC in the cervical and middle thirds were observed, regardless of the period of storage (P > 0.05). In the apical third, GC and RU showed similar bond strength but higher than other groups (P > 0.05). After 12 months, GC showed the highest bond strength (P < 0.05). Bond strength to post-space dentin decreased over time, regardless of the cementation system used. Cohesive failure was the most frequent, regardless of the period of storage, cementation system, and post-space third. Tag formation was similar among all groups. After 12 months, GC showed the highest bond strength values.

Abstract Image

Abstract Image

Abstract Image

老化和胶结系统对纤维后胶结后与根-牙本质结合强度的影响。
本研究评估了使用玻璃离聚物和树脂胶结物对纤维桩的老化和胶结对推出粘结强度、失效模式和树脂标签形成的影响。使用了一百二十颗牛门牙。后间隙制备后,根据所用的胶结系统将试样随机分为12组(n=10):GC-GC Gold Label Luting&Lineing);RL-RelyX Luting 2;MC-MaxCem精英;RU-RelyX U200和老化期(24小时、6个月和12个月)。通过推出结合强度测试和共聚焦激光扫描显微镜获得并分析来自颈部、中部和顶端三分之一的切片。使用单向方差分析和Tukey的事后检验,显著性水平为5%。对于推出结合强度测试,无论储存时间长短,颈三分之一和中三分之一的GC、RU和MC之间都没有差异(P>0.05)。在根尖三分之一,GC和RU表现出相似的结合强度,但高于其他组(P>0.05);12个月后,GC表现出最高的结合强度(P<0.05)。与间隙后牙本质的结合强度随着时间的推移而降低,而与所使用的胶结系统无关。粘结失效是最常见的,无论储存期、胶结系统和后期空间如何。标签形成在所有组之间是相似的。12个月后,GC显示出最高的结合强度值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Brazilian dental journal
Brazilian dental journal Dentistry-Dentistry (all)
CiteScore
2.20
自引率
0.00%
发文量
69
审稿时长
12 weeks
期刊介绍: Brazilian Dental Journal, publishes Full-Length Papers, Short Communications and Case Reports, dealing with dentistry or related disciplines and edited six times a year.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信