Anatomical Feasibility of an Off-the-shelf Single-Renal Scalloped Stent-Graft for Hostile Neck Abdominal Aortic Aneurysm: A Preclinical Study.

IF 1.7 2区 医学 Q3 PERIPHERAL VASCULAR DISEASE
Journal of Endovascular Therapy Pub Date : 2025-02-01 Epub Date: 2023-04-25 DOI:10.1177/15266028231169164
Stefano Gennai, Nicola Leone, Francesco Andreoli, Mattia Migliari, Roberto Silingardi
{"title":"Anatomical Feasibility of an Off-the-shelf Single-Renal Scalloped Stent-Graft for Hostile Neck Abdominal Aortic Aneurysm: A Preclinical Study.","authors":"Stefano Gennai, Nicola Leone, Francesco Andreoli, Mattia Migliari, Roberto Silingardi","doi":"10.1177/15266028231169164","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To evaluate the feasibility of a standardized single-renal scallop stent-graft.</p><p><strong>Design: </strong>Preclinical, single-center, real-world, all-comers, retrospective cohort study.</p><p><strong>Methods: </strong>A total of 1347 abdominal aortic aneurysm (AAA) repairs (endovascular and open) performed between 2010 and 2020 were screened for elective treatment and retrievable preoperative high-quality computed tomography angiography (CTA) performed <6 months of the surgical procedure. Six hundred of the included CTAs involved prespecified measurements and a morphological assessment protocol (NCT05150873). The proximal sealing zones suitable for standard stent-graft implantations were further analyzed (N=547). The primary outcome assessed the feasibility of 2 single-renal scallop designs (10×10 mm and 15×10 mm, height × width). The feasibility was the inter-renal length ≥10 mm and ≥15 mm for prototypes #10 and #15, respectively. The secondary outcome quantified hypothetical length and surface improvements comparing those suitable for investigational devices implantation (study group) versus those not (control group).</p><p><strong>Results: </strong>Of the total, 24.7% (n=135) was feasible with prototype #10. The study versus control group sealing zones were shorter (p=0.008), with a smaller surface (p=0.009) and a higher alpha angle (p=0.039). The length and surface area increased by about 25% and 23%, respectively, (both p<0.001) within the study group and became significantly better versus the control group (standard stent-graft; both p<0.001). Of the total, 7.1% (n=39) was suitable for prototype #15. The study versus control group sealing zones were shorter (p=0.148), with a smaller surface (p=0.077) and a higher alpha angle (p=0.027). The length and surface area increased by about 34% and 31%, respectively, (both p<0.001) within the study group and became significantly higher versus the control group (standard stent-graft; both p<0.001).</p><p><strong>Conclusions: </strong>The use of single-renal scalloped stent-graft might be feasible in a considerable number of AAA patients. The breakthrough stands in treating hostile AAAs presenting in mismatched renal arteries, keeping the complexity of the repair as similar as possible to standard endovascular repair with a remarkable improvement in sealing.</p><p><strong>Clinical impact: </strong>The anatomic feasibility of a single renal stent graft for the treatment of \"hostile\" abdominal aortic aneurysm (AAA) with mismatched renal arteries was evaluated. The experimental device could be feasible in a considerable number of patients with AAA, approaching 25%, and demonstrate significant improvements in sealing. As far as we know, this is the first paper to report the prevalence of mismatched renal arteries in a large cohort of AAA patients in the real world, while proposing a dedicated device. The breakthrough is to keep the complexity of the repair as close as possible to standard endovascular repair.</p>","PeriodicalId":50210,"journal":{"name":"Journal of Endovascular Therapy","volume":" ","pages":"159-169"},"PeriodicalIF":1.7000,"publicationDate":"2025-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Endovascular Therapy","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028231169164","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/4/25 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To evaluate the feasibility of a standardized single-renal scallop stent-graft.

Design: Preclinical, single-center, real-world, all-comers, retrospective cohort study.

Methods: A total of 1347 abdominal aortic aneurysm (AAA) repairs (endovascular and open) performed between 2010 and 2020 were screened for elective treatment and retrievable preoperative high-quality computed tomography angiography (CTA) performed <6 months of the surgical procedure. Six hundred of the included CTAs involved prespecified measurements and a morphological assessment protocol (NCT05150873). The proximal sealing zones suitable for standard stent-graft implantations were further analyzed (N=547). The primary outcome assessed the feasibility of 2 single-renal scallop designs (10×10 mm and 15×10 mm, height × width). The feasibility was the inter-renal length ≥10 mm and ≥15 mm for prototypes #10 and #15, respectively. The secondary outcome quantified hypothetical length and surface improvements comparing those suitable for investigational devices implantation (study group) versus those not (control group).

Results: Of the total, 24.7% (n=135) was feasible with prototype #10. The study versus control group sealing zones were shorter (p=0.008), with a smaller surface (p=0.009) and a higher alpha angle (p=0.039). The length and surface area increased by about 25% and 23%, respectively, (both p<0.001) within the study group and became significantly better versus the control group (standard stent-graft; both p<0.001). Of the total, 7.1% (n=39) was suitable for prototype #15. The study versus control group sealing zones were shorter (p=0.148), with a smaller surface (p=0.077) and a higher alpha angle (p=0.027). The length and surface area increased by about 34% and 31%, respectively, (both p<0.001) within the study group and became significantly higher versus the control group (standard stent-graft; both p<0.001).

Conclusions: The use of single-renal scalloped stent-graft might be feasible in a considerable number of AAA patients. The breakthrough stands in treating hostile AAAs presenting in mismatched renal arteries, keeping the complexity of the repair as similar as possible to standard endovascular repair with a remarkable improvement in sealing.

Clinical impact: The anatomic feasibility of a single renal stent graft for the treatment of "hostile" abdominal aortic aneurysm (AAA) with mismatched renal arteries was evaluated. The experimental device could be feasible in a considerable number of patients with AAA, approaching 25%, and demonstrate significant improvements in sealing. As far as we know, this is the first paper to report the prevalence of mismatched renal arteries in a large cohort of AAA patients in the real world, while proposing a dedicated device. The breakthrough is to keep the complexity of the repair as close as possible to standard endovascular repair.

一种现成的单肾扇贝支架移植治疗恶性颈部腹主动脉瘤的解剖学可行性:临床前研究。
目的:评价标准化单肾扇贝支架移植的可行性。设计:临床前、单中心、真实世界、所有患者、回顾性队列研究。方法:对2010年至2020年间进行的1347例腹主动脉瘤(AAA)修复(血管内和开放)进行筛选,选择治疗并进行术前可检索的高质量计算机断层扫描血管造影(CTA)。结果:其中24.7% (n=135)的原型#10是可行的。实验组与对照组相比,封闭区更短(p=0.008),表面更小(p=0.009), α角更大(p=0.039)。结论:单肾扇贝支架移植在相当数量的AAA患者中是可行的。突破在于治疗出现在不匹配肾动脉的不良AAAs,使修复的复杂性尽可能与标准血管内修复相似,并显著改善了密封。临床影响:评估单肾支架治疗肾动脉不匹配的“敌对”腹主动脉瘤(AAA)的解剖学可行性。该实验装置在相当数量的AAA患者中是可行的,接近25%,并且在密封方面有显着改善。据我们所知,这是第一篇报道现实世界中大量AAA患者肾动脉错配发生率的论文,同时提出了一种专用装置。其突破在于使修复的复杂性尽可能接近标准的血管内修复。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
15.40%
发文量
203
审稿时长
6-12 weeks
期刊介绍: The Journal of Endovascular Therapy (formerly the Journal of Endovascular Surgery) was established in 1994 as a forum for all physicians, scientists, and allied healthcare professionals who are engaged or interested in peripheral endovascular techniques and technology. An official publication of the International Society of Endovascular Specialists (ISEVS), the Journal of Endovascular Therapy publishes peer-reviewed articles of interest to clinicians and researchers in the field of peripheral endovascular interventions.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信