LASERS: Modeling of a 10-liter electric-discharge XeCl laser

A. Dem’yanov, I. Kochetov, A. Napartovich, M. Capitelli, C. Gorse, S. Longo
{"title":"LASERS: Modeling of a 10-liter electric-discharge XeCl laser","authors":"A. Dem’yanov, I. Kochetov, A. Napartovich, M. Capitelli, C. Gorse, S. Longo","doi":"10.1070/QE1992V022N09ABEH003597","DOIUrl":null,"url":null,"abstract":"Theoretical models developed independently by groups in Russia and Italy were used to describe the operation of a 10-liter electric-discharge XeCl laser. The calculations gave similar results for an HCl pressure of 1.5 Torr, but diverged strongly at low (0.5 Torr) and high (4 Torr) HCl pressures. The reasons for this discrepancy were determined. It was found that homogeneous models cannot describe the experimental data satisfactorily.","PeriodicalId":21878,"journal":{"name":"Soviet Journal of Quantum Electronics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1992-09-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Soviet Journal of Quantum Electronics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1070/QE1992V022N09ABEH003597","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Theoretical models developed independently by groups in Russia and Italy were used to describe the operation of a 10-liter electric-discharge XeCl laser. The calculations gave similar results for an HCl pressure of 1.5 Torr, but diverged strongly at low (0.5 Torr) and high (4 Torr) HCl pressures. The reasons for this discrepancy were determined. It was found that homogeneous models cannot describe the experimental data satisfactorily.
激光器:10升放电XeCl激光器的建模
由俄罗斯和意大利的小组独立开发的理论模型被用来描述10升放电XeCl激光器的操作。在HCl压力为1.5 Torr时,计算结果相似,但在低(0.5 Torr)和高(4 Torr) HCl压力下,计算结果大相径庭。造成这种差异的原因已经确定。结果表明,均匀模型不能很好地描述实验数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信