Use of automatic steam sterilizer for disinfection of immunobiological waste contaminated with pathogenic biological agents

A. D. Belousov, M. V. Antonycheva, O. A. Volokh, Elena Gennadievna Abramova, Marina Vyacheslavovna Gordeeva, Mikhail Mikhailovich Chalbushev, A. K. Nikiforov
{"title":"Use of automatic steam sterilizer for disinfection of immunobiological waste contaminated with pathogenic biological agents","authors":"A. D. Belousov, M. V. Antonycheva, O. A. Volokh, Elena Gennadievna Abramova, Marina Vyacheslavovna Gordeeva, Mikhail Mikhailovich Chalbushev, A. K. Nikiforov","doi":"10.35411/2076-457x-2023-2-14-22","DOIUrl":null,"url":null,"abstract":"One of the ways to neutralize immunobiological production waste is their treatment in sterilizers with saturated water vapor under pressure. Currently, medical and pharmaceutical industries and laboratories use sterilizers with sterilization and disinfection programs preset by manufacturers. Decontamination modes are defined in Federal sanitary rules, norms and hygienic standards, SanPiN 3.3686-21, while the parameters of preliminary phases of the cycle must be tested experimentally and validated for specific conditions. Within the frames of this study, we have tested the modes of disinfection of an automatic steam sterilizer by the example of waste products from the production of cholera vaccine and anti-rabies immunoglobulin manufactured by the FSSI Russian Anti-Plague Institute «Microbe» of the Rospotrebnadzor. The wastes are used nutrient media, carcasses of laboratory animals (rabbits) and consumables. The chamber was loaded with «clean» objects in quantity and configuration, repeating the loading of material with pathogenic biological agents (PBA). The mode of inactivation inside the chamber and the objects was controlled by physical, chemical and biological methods. Based on the results of the experiments, corrective actions were taken to change the program and design of containers for autoclaving. It was concluded that the default disinfection programs set by manufacturers do not fully take into account specific conditions and need to be adjusted with further validation. It is necessary to develop standard operating procedures for personnel involved in the decontamination of pathogenic materials, in which should be stated the order of placement of objects and the means of control in the containers with PBA and the sterilizer chamber. Keywords: steam sterilizers, pathogenic biological agents, disinfection with saturated water vapor, phases of the steam disinfection cycle, validation.","PeriodicalId":11317,"journal":{"name":"Disinfection affairs","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2023-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Disinfection affairs","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.35411/2076-457x-2023-2-14-22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

One of the ways to neutralize immunobiological production waste is their treatment in sterilizers with saturated water vapor under pressure. Currently, medical and pharmaceutical industries and laboratories use sterilizers with sterilization and disinfection programs preset by manufacturers. Decontamination modes are defined in Federal sanitary rules, norms and hygienic standards, SanPiN 3.3686-21, while the parameters of preliminary phases of the cycle must be tested experimentally and validated for specific conditions. Within the frames of this study, we have tested the modes of disinfection of an automatic steam sterilizer by the example of waste products from the production of cholera vaccine and anti-rabies immunoglobulin manufactured by the FSSI Russian Anti-Plague Institute «Microbe» of the Rospotrebnadzor. The wastes are used nutrient media, carcasses of laboratory animals (rabbits) and consumables. The chamber was loaded with «clean» objects in quantity and configuration, repeating the loading of material with pathogenic biological agents (PBA). The mode of inactivation inside the chamber and the objects was controlled by physical, chemical and biological methods. Based on the results of the experiments, corrective actions were taken to change the program and design of containers for autoclaving. It was concluded that the default disinfection programs set by manufacturers do not fully take into account specific conditions and need to be adjusted with further validation. It is necessary to develop standard operating procedures for personnel involved in the decontamination of pathogenic materials, in which should be stated the order of placement of objects and the means of control in the containers with PBA and the sterilizer chamber. Keywords: steam sterilizers, pathogenic biological agents, disinfection with saturated water vapor, phases of the steam disinfection cycle, validation.
应用自动蒸汽灭菌器对受致病性生物制剂污染的免疫生物废物进行消毒
其中一种中和免疫生物生产废物的方法是在高压下用饱和水蒸气灭菌器处理它们。目前,医疗和制药行业和实验室使用的消毒器是由制造商预置的灭菌和消毒程序。去污模式在联邦卫生规则、规范和卫生标准SanPiN 3.3686-21中有定义,而循环的初步阶段的参数必须经过实验测试并针对特定条件进行验证。在本研究的框架内,我们以FSSI俄罗斯Rospotrebnadzor的“微生物”抗鼠疫研究所生产的霍乱疫苗和抗狂犬病免疫球蛋白的废料为例,测试了自动蒸汽灭菌器的消毒模式。这些废物是用过的营养培养基、实验动物(兔子)的尸体和消耗品。该室在数量和结构上装载“清洁”物体,重复装载病原体生物制剂(PBA)的材料。通过物理、化学和生物三种方法控制实验室内和实验对象的灭活方式。根据实验结果,对高压灭菌容器的程序和设计进行了改进。结论是,生产企业设置的默认消毒方案没有充分考虑具体情况,需要进一步验证进行调整。有必要为参与病原材料净化的人员制定标准操作程序,其中应说明物品的放置顺序和在装有PBA的容器和灭菌室中的控制方法。关键词:蒸汽灭菌器,致病性生物制剂,饱和水蒸气消毒,蒸汽消毒循环阶段,验证
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
文献相关原料
公司名称 产品信息 采购帮参考价格
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信