Ex vivo evaluation of the effectiveness of XP-endo Finisher on the removal of smear layer from the root canal

Sângela Maria da Silva Pereira, C. Carvalho, Rudys Rodolfo Tavarez, P. Nelson-Filho, L. A. D. Da Silva, E. M. Maia Filho
{"title":"Ex vivo evaluation of the effectiveness of XP-endo Finisher on the removal of smear layer from the root canal","authors":"Sângela Maria da Silva Pereira, C. Carvalho, Rudys Rodolfo Tavarez, P. Nelson-Filho, L. A. D. Da Silva, E. M. Maia Filho","doi":"10.1590/1981-863720200005720210021","DOIUrl":null,"url":null,"abstract":"ABSTRACT Objective: The aim of this study was to evaluate the effectiveness of XP-endo Finisher (XP) on removal of the smear layer in root canals by comparing different irrigation protocols. Methods: Seventy-two human single-rooted teeth were similarly instrumented using R25 Reciproc files (VDW, Munich, Germany) applied in reciprocating mode with a VDW GOLD endo motor (VDW, Munich, Germany). The working length was determined at 1 mm short of the apical foramen. The canals were irrigated with 5 mL of 2.5% sodium hypochlorite during instrumentation. The teeth were divided at random into six groups (n=12). A control group, which was not submitted to the final irrigation protocol, and five experimental groups with different irrigants and agitation techniques: EDTA/File, EDTA/XP, EDTA/Passive Ultrasonic Irrigation (PUI), Distilled Water (DW)/XP, and DW/PUI). Smear layer removal quality scores were assessed in the apical, middle, and cervical thirds of the root canal based on images obtained by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test, followed by two-by-two comparisons with the Dunn test (α=5%). Results: EDTA/File, EDTA/PUI, and EDTA/XP groups demonstrated significantly lower scores than the other groups (P<0.05) in all thirds evaluated. No significant difference was observed between the groups in which distilled water was used and the control group in all thirds evaluated (P> 0.05). Conclusion: The XP-endo Finisher file did not increase the efficiency of EDTA in removal of the smear layer in root canals.","PeriodicalId":30069,"journal":{"name":"RGO Revista Gaucha de Odontologia","volume":"60 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RGO Revista Gaucha de Odontologia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/1981-863720200005720210021","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

ABSTRACT Objective: The aim of this study was to evaluate the effectiveness of XP-endo Finisher (XP) on removal of the smear layer in root canals by comparing different irrigation protocols. Methods: Seventy-two human single-rooted teeth were similarly instrumented using R25 Reciproc files (VDW, Munich, Germany) applied in reciprocating mode with a VDW GOLD endo motor (VDW, Munich, Germany). The working length was determined at 1 mm short of the apical foramen. The canals were irrigated with 5 mL of 2.5% sodium hypochlorite during instrumentation. The teeth were divided at random into six groups (n=12). A control group, which was not submitted to the final irrigation protocol, and five experimental groups with different irrigants and agitation techniques: EDTA/File, EDTA/XP, EDTA/Passive Ultrasonic Irrigation (PUI), Distilled Water (DW)/XP, and DW/PUI). Smear layer removal quality scores were assessed in the apical, middle, and cervical thirds of the root canal based on images obtained by scanning electron microscopy. Data were analyzed using the Kruskal-Wallis test, followed by two-by-two comparisons with the Dunn test (α=5%). Results: EDTA/File, EDTA/PUI, and EDTA/XP groups demonstrated significantly lower scores than the other groups (P<0.05) in all thirds evaluated. No significant difference was observed between the groups in which distilled water was used and the control group in all thirds evaluated (P> 0.05). Conclusion: The XP-endo Finisher file did not increase the efficiency of EDTA in removal of the smear layer in root canals.
体外评价XP-endo Finisher清除根管涂片层的有效性
摘要目的:本研究通过比较不同灌洗方案,评价XP-endo Finisher (XP)对根管内涂抹层清除的效果。方法:使用R25 Reciproc锉(VDW, Munich, Germany)和VDW GOLD endo马达(VDW, Munich, Germany)以往复方式对72颗人单根牙齿进行类似的矫治。工作长度确定在根尖孔短1mm处。在器械过程中,用5ml 2.5%次氯酸钠冲洗管道。将牙齿随机分为6组(n=12)。对照组(未提交最终冲洗方案)和5个不同冲洗和搅拌技术的实验组:EDTA/File、EDTA/XP、EDTA/被动超声冲洗(PUI)、蒸馏水(DW)/XP和DW/PUI。根据扫描电镜获得的图像,对根管的根尖、中间和颈部三分之一的涂片层去除质量评分进行评估。采用Kruskal-Wallis检验对数据进行分析,然后采用Dunn检验进行二乘二比较(α=5%)。结果:EDTA/File组、EDTA/PUI组、EDTA/XP组得分显著低于其他组(P < 0.05)。结论:XP-endo Finisher锉对EDTA清除根管内涂片层的效果无显著影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
35
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信