The Safety of Long Inframammary Fold to Nipple Lengths in Inferior Pedicle Breast Reductions: A Decade of Experience.

Eplasty Pub Date : 2023-01-01
Taruni A Kumar, Aran Yoo, Adeem M Nachabe, Daniel J Womac, Jonathan C Boraski
{"title":"The Safety of Long Inframammary Fold to Nipple Lengths in Inferior Pedicle Breast Reductions: A Decade of Experience.","authors":"Taruni A Kumar,&nbsp;Aran Yoo,&nbsp;Adeem M Nachabe,&nbsp;Daniel J Womac,&nbsp;Jonathan C Boraski","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Breast reduction is one of the most common procedures performed by plastic surgeons, and the inferior pedicle is a technique frequently used to maintain vascular supply to the nipple areolar complex (NAC). One of the relative contraindications for its use is the presence of a long nipple-to-inframammary fold (IMF) length; however, in the authors' practice, inferior pedicle mammoplasties have been successfully performed for over 10 years on almost all patients.</p><p><strong>Methods: </strong>The authors performed a retrospective study including patients who underwent bilateral breast reduction with inferior pedicle technique from October 2009 to April 2021 by 2 different surgeons in New Orleans, Louisiana. Patient baseline characteristics as well as surgical outcomes were recorded.</p><p><strong>Results: </strong>The study population consisted of 221 patients and 436 breasts. The average age of patients was 38 years, and average body mass index was 32.35 kg/m<sup>2</sup>. Average follow-up time was 135 days. The average nipple-to-IMF distance for the patient population was 16.03 cm, and the average pedicle width of the inferior pedicles used for breast reductions was 10 cm. There was no incidence of total nipple necrosis. The most common complication was a superficial wound at the T junction of the breast reduction incision (23%).</p><p><strong>Conclusions: </strong>Breast reductions with an inferior pedicle are safe to perform, without the risk of nipple necrosis, for all patients with inferior pedicle length up to 33 cm.</p>","PeriodicalId":11687,"journal":{"name":"Eplasty","volume":"23 ","pages":"e11"},"PeriodicalIF":0.0000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10008301/pdf/eplasty-23-e11.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eplasty","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Breast reduction is one of the most common procedures performed by plastic surgeons, and the inferior pedicle is a technique frequently used to maintain vascular supply to the nipple areolar complex (NAC). One of the relative contraindications for its use is the presence of a long nipple-to-inframammary fold (IMF) length; however, in the authors' practice, inferior pedicle mammoplasties have been successfully performed for over 10 years on almost all patients.

Methods: The authors performed a retrospective study including patients who underwent bilateral breast reduction with inferior pedicle technique from October 2009 to April 2021 by 2 different surgeons in New Orleans, Louisiana. Patient baseline characteristics as well as surgical outcomes were recorded.

Results: The study population consisted of 221 patients and 436 breasts. The average age of patients was 38 years, and average body mass index was 32.35 kg/m2. Average follow-up time was 135 days. The average nipple-to-IMF distance for the patient population was 16.03 cm, and the average pedicle width of the inferior pedicles used for breast reductions was 10 cm. There was no incidence of total nipple necrosis. The most common complication was a superficial wound at the T junction of the breast reduction incision (23%).

Conclusions: Breast reductions with an inferior pedicle are safe to perform, without the risk of nipple necrosis, for all patients with inferior pedicle length up to 33 cm.

长乳下褶对乳头长度的安全性:十年的经验。
背景:乳房缩小是整形外科最常见的手术之一,下蒂是一种常用的技术,用于维持乳头乳晕复合体(NAC)的血管供应。其使用的相对禁忌症之一是存在较长的乳头到乳房下褶皱(IMF)长度;然而,在作者的实践中,近10年来几乎所有患者都成功地进行了下蒂乳房成形术。方法:作者对2009年10月至2021年4月在路易斯安那州新奥尔良由2位不同的外科医生行双侧乳房下蒂缩乳术的患者进行回顾性研究。记录患者的基线特征以及手术结果。结果:研究人群包括221名患者和436个乳房。患者平均年龄38岁,平均体重指数32.35 kg/m2。平均随访时间为135天。患者乳头至乳头状动脉的平均距离为16.03 cm,下蒂缩乳的平均宽度为10 cm。无乳头全坏死发生。最常见的并发症是缩乳切口T型交界处的浅表伤口(23%)。结论:对于所有下椎弓根长度大于33 cm的患者,采用下椎弓根的乳房缩小术是安全的,没有乳头坏死的风险。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信