The association between NIRS and Doppler ultrasonography in preterm infants with patent ductus arteriosus

Didem Arman, S. Sancak, T. Gürsoy, S. Topçuoğlu, G. Karatekin, F. Ovalı
{"title":"The association between NIRS and Doppler ultrasonography in preterm infants with patent ductus arteriosus","authors":"Didem Arman, S. Sancak, T. Gürsoy, S. Topçuoğlu, G. Karatekin, F. Ovalı","doi":"10.1080/14767058.2019.1639661","DOIUrl":null,"url":null,"abstract":"Abstract Objective: To determine if near-infrared spectroscopy (NIRS), which is easier to obtain than Doppler ultrasonography (USG), may be used in accordance with Doppler USG to provide additional data for assessment of organ blood flow velocities in preterm infants with hemodynamically significant PDA. Study design: Thirty-one infants who were treated with ibuprofen for closure of PDA were monitored continuously with NIRS. Cerebral, mesenteric, and renal arterial blood flow velocities were measured with Doppler USG before and after the treatment. Results: While cerebral, mesenteric, and renal fractional oxygen extraction (FTOE) measurements decreased significantly (p = .042, p < .001, p < .001, respectively), NIRS measurements (p = .016, p < .001, p < .001, respectively) and mean blood flow velocities (p = .003, p = .011, p = .002, respectively) increased significantly after the treatment. There was a significant correlation between pretreatment cerebral and mesenteric FTOE and resistive index (RI) values (r = 0.45, p = .01, and r = 0.46, p = .01, respectively). However, no correlation was observed between renal FTOE values and renal RI (r = 0.33, p = .06). Posttreatment cerebral, renal, and mesenteric FTOE values correlated positively with corresponding RI (r = 0.41, p = .02; r = 0.39, p = .02; r = 0.65, p < 01; respectively). Pretreatment and posttreatment cerebral, mesenteric, and renal FTOE values and arterial mean velocities were inversely correlated (pretreatment: r = 0.69, p < .01; r = 0.72, p < .01; r = 0.77, p < .01; posttreatment: r = 0.54, p = .01; r = 0.69, p < .01; r = 0.38, p = .01; respectively). Conclusion: As Doppler and NIRS measurements correlated significantly, we concluded that NIRS might be used in monitoring organ blood flow in preterm infants with PDA, which may provide additional data for management of this condition.","PeriodicalId":22921,"journal":{"name":"The Journal of Maternal-Fetal & Neonatal Medicine","volume":"6 1","pages":"1245 - 1252"},"PeriodicalIF":0.0000,"publicationDate":"2020-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"22","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Maternal-Fetal & Neonatal Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/14767058.2019.1639661","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 22

Abstract

Abstract Objective: To determine if near-infrared spectroscopy (NIRS), which is easier to obtain than Doppler ultrasonography (USG), may be used in accordance with Doppler USG to provide additional data for assessment of organ blood flow velocities in preterm infants with hemodynamically significant PDA. Study design: Thirty-one infants who were treated with ibuprofen for closure of PDA were monitored continuously with NIRS. Cerebral, mesenteric, and renal arterial blood flow velocities were measured with Doppler USG before and after the treatment. Results: While cerebral, mesenteric, and renal fractional oxygen extraction (FTOE) measurements decreased significantly (p = .042, p < .001, p < .001, respectively), NIRS measurements (p = .016, p < .001, p < .001, respectively) and mean blood flow velocities (p = .003, p = .011, p = .002, respectively) increased significantly after the treatment. There was a significant correlation between pretreatment cerebral and mesenteric FTOE and resistive index (RI) values (r = 0.45, p = .01, and r = 0.46, p = .01, respectively). However, no correlation was observed between renal FTOE values and renal RI (r = 0.33, p = .06). Posttreatment cerebral, renal, and mesenteric FTOE values correlated positively with corresponding RI (r = 0.41, p = .02; r = 0.39, p = .02; r = 0.65, p < 01; respectively). Pretreatment and posttreatment cerebral, mesenteric, and renal FTOE values and arterial mean velocities were inversely correlated (pretreatment: r = 0.69, p < .01; r = 0.72, p < .01; r = 0.77, p < .01; posttreatment: r = 0.54, p = .01; r = 0.69, p < .01; r = 0.38, p = .01; respectively). Conclusion: As Doppler and NIRS measurements correlated significantly, we concluded that NIRS might be used in monitoring organ blood flow in preterm infants with PDA, which may provide additional data for management of this condition.
早产儿动脉导管未闭的近红外光谱与多普勒超声的关系
摘要目的:探讨近红外光谱(NIRS)技术是否可与多普勒超声(USG)技术相结合,为血流动力学显著性PDA早产儿器官血流速度评估提供额外数据。研究设计:31名接受布洛芬治疗的婴儿用近红外光谱仪连续监测PDA。治疗前后分别用多普勒USG测量脑、肠系膜、肾动脉血流速度。结果:脑、肠系膜和肾的分数氧提取(FTOE)测量值显著降低(p =。042, p <。001, p <。001),近红外光谱测量(p =。[16], p <。001, p <。0.001)和平均血流速度(p = 0.001)。003, p =。011, p =。002,分别)治疗后显著增高。预处理脑及肠系膜FTOE与阻力指数(RI)值有显著相关性(r = 0.45, p = 0.45)。0.01, r = 0.46, p =。分别为01)。然而,肾脏FTOE值与肾脏RI之间没有相关性(r = 0.33, p = 0.06)。治疗后脑、肾、肠系膜FTOE值与相应的RI呈正相关(r = 0.41, p = 0.02;R = 0.39, p = 0.02;R = 0.65, p < 01;分别)。治疗前后脑、肠系膜、肾FTOE值与动脉平均流速呈负相关(治疗前:r = 0.69, p < 0.01;R = 0.72, p < 0.01;R = 0.77, p < 0.01;后处理:r = 0.54, p = 0.01;R = 0.69, p < 0.01;R = 0.38, p = 0.01;分别)。结论:由于多普勒和近红外光谱测量结果显著相关,我们得出结论,近红外光谱可能用于监测PDA早产儿的器官血流,这可能为该疾病的治疗提供额外的数据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信