Modélisation des temps de réponse des capteurs chimiques

Francis Ménil
{"title":"Modélisation des temps de réponse des capteurs chimiques","authors":"Francis Ménil","doi":"10.1016/S1387-1609(01)01334-2","DOIUrl":null,"url":null,"abstract":"<div><p>Modelling consists of considering the response and recovery times of a sensor to the target chemical species, as the sum of an ‘intrinsic’ response/recovery time, independent of the experimental conditions, and of an ‘extrinsic’ one, linked to the volume of the measurement cell and to the fluid flow. The experimental response/recovery times being almost always dominated by the extrinsic part, a dissymmetry between the response and recovery signals is observed for sensors whose response is not linear with the concentration of the target chemical species.</p></div>","PeriodicalId":100305,"journal":{"name":"Comptes Rendus de l'Académie des Sciences - Series IIC - Chemistry","volume":"4 12","pages":"Pages 899-904"},"PeriodicalIF":0.0000,"publicationDate":"2001-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S1387-1609(01)01334-2","citationCount":"11","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Comptes Rendus de l'Académie des Sciences - Series IIC - Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1387160901013342","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 11

Abstract

Modelling consists of considering the response and recovery times of a sensor to the target chemical species, as the sum of an ‘intrinsic’ response/recovery time, independent of the experimental conditions, and of an ‘extrinsic’ one, linked to the volume of the measurement cell and to the fluid flow. The experimental response/recovery times being almost always dominated by the extrinsic part, a dissymmetry between the response and recovery signals is observed for sensors whose response is not linear with the concentration of the target chemical species.

化学传感器响应时间建模
建模包括考虑传感器对目标化学物质的响应和恢复时间,作为独立于实验条件的“内在”响应/恢复时间和与测量单元的体积和流体流动有关的“外在”响应/恢复时间的总和。实验响应/恢复时间几乎总是由外部部分主导,对于响应与目标化学物质浓度不是线性的传感器,可以观察到响应和恢复信号之间的不对称性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信