L. Pedrotti, I. Crivellari, A. Degrate, Federica De Rosa, F. Ruggiero, M. Mosconi
{"title":"Interpreting neonatal hip sonography: intraobserver and interobserver variability","authors":"L. Pedrotti, I. Crivellari, A. Degrate, Federica De Rosa, F. Ruggiero, M. Mosconi","doi":"10.1097/BPB.0000000000000670","DOIUrl":null,"url":null,"abstract":"The purpose of this study is to state the reliability of neonatal hip ultrasound interpretation, defining the intra and interoperator variability in the evaluation of the scans. We considered a sample of 2071 scans (coming from 798 patients who attended the screening programme for hip dysplasia), which were interpreted by the operator who obtained and read the images at the screening time and then by a different operator who saw the images for the first time. Both the intra and interoperator variability of α and β angles’ values resulted statistically not significative (intraclass correlation coefficient > 0.8) and determining a class shift (according to the Graf’s classification) in a nonstatistically significative number of cases (agreement percentage >91% and Cohen’s κ >0.8). Hip sonography can reliably detect hip dysplasia and the intra and interoperator variability in the interpretation of the exam is NS when the examination is correctly executed.","PeriodicalId":16709,"journal":{"name":"Journal of Pediatric Orthopaedics B","volume":"18 1","pages":"214 - 218"},"PeriodicalIF":0.0000,"publicationDate":"2020-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Pediatric Orthopaedics B","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1097/BPB.0000000000000670","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9
Abstract
The purpose of this study is to state the reliability of neonatal hip ultrasound interpretation, defining the intra and interoperator variability in the evaluation of the scans. We considered a sample of 2071 scans (coming from 798 patients who attended the screening programme for hip dysplasia), which were interpreted by the operator who obtained and read the images at the screening time and then by a different operator who saw the images for the first time. Both the intra and interoperator variability of α and β angles’ values resulted statistically not significative (intraclass correlation coefficient > 0.8) and determining a class shift (according to the Graf’s classification) in a nonstatistically significative number of cases (agreement percentage >91% and Cohen’s κ >0.8). Hip sonography can reliably detect hip dysplasia and the intra and interoperator variability in the interpretation of the exam is NS when the examination is correctly executed.
本研究的目的是陈述新生儿髋关节超声解释的可靠性,定义扫描评估中操作者内部和操作者之间的可变性。我们考虑了2071个扫描样本(来自参加髋关节发育不良筛查计划的798名患者),这些扫描由在筛查时获得并读取图像的操作员进行解释,然后由第一次看到图像的另一个操作员进行解释。α和β角度值的内部和操作符间变异性均导致统计学上不显著(类内相关系数>0.8),并在非统计学显著的情况下(一致性百分比>91%,Cohen ' s κ >0.8)确定类移位(根据Graf分类)。髋关节超声检查可以可靠地检测出髋关节发育不良,当检查正确执行时,检查结果的内部和操作者之间的差异是NS的。