Willemina A van Veldhuizen, Richte C L Schuurmann, Roy Zuidema, Anna C M Geraedts, Frank F A IJpma, Rogier H J Kropman, George A Antoniou, Marc R H M van Sambeek, Ron Balm, Jelmer M Wolterink, Jean-Paul P M de Vries
{"title":"A Statistical Shape Model of Infrarenal Aortic Necks in Patients With and Without Late Type Ia Endoleak After Endovascular Aneurysm Repair.","authors":"Willemina A van Veldhuizen, Richte C L Schuurmann, Roy Zuidema, Anna C M Geraedts, Frank F A IJpma, Rogier H J Kropman, George A Antoniou, Marc R H M van Sambeek, Ron Balm, Jelmer M Wolterink, Jean-Paul P M de Vries","doi":"10.1177/15266028221149913","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Hostile aortic neck characteristics, including short length, severe suprarenal and infrarenal angulation, conicity, and large diameter, have been associated with increased risk for type Ia endoleak (T1aEL) after endovascular aneurysm repair (EVAR). This study investigates the mid-term discriminative ability of a statistical shape model (SSM) of the infrarenal aortic neck morphology compared with or in combination with conventional measurements in patients who developed T1aEL post-EVAR.</p><p><strong>Materials and methods: </strong>The dataset composed of EVAR patients who developed a T1aEL during follow-up and a control group without T1aEL. Principal component (PC) analysis was performed using a parametrization to create an SSM. Three logistic regression models were created. To discriminate between patients with and without T1aEL, sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve (AUC) were calculated.</p><p><strong>Results: </strong>In total, 126 patients (84% male) were included. Median follow-up time in T1aEl group and control group was 52 (31, 78.5) and 51 (40, 62.5) months, respectively. Median follow-up time was not statistically different between the groups (p=0.72). A statistically significant difference between the median PC scores of the T1aEL and control groups was found for the first, eighth, and ninth PC. Sensitivity, specificity, and AUC values for the SSM-based versus the conventional measurements-based logistic regression models were 79%, 70%, and 0.82 versus 74%, 73%, and 0.85, respectively. The model of the SSM and conventional measurements combined resulted in sensitivity, specificity, and AUC of 81%, 81%, and 0.92.</p><p><strong>Conclusion: </strong>An SSM of the infrarenal aortic neck determines its 3-dimensional geometry. The SSM is a potential valuable tool for risk stratification and T1aEL prediction in EVAR. The SSM complements the conventional measurements of the individual preoperative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleak after standard EVAR.</p><p><strong>Clinical impact: </strong>A statistical shape model (SSM) determines the 3-dimensional geometry of the infrarenal aortic neck. The SSM complements the conventional measurements of the individual pre-operative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleaks post-EVAR. The SSM is a potential valuable tool for risk stratification and late T1aEL prediction in EVAR and it is a first step toward implementation of a treatment planning support tool in daily clinical practice.</p>","PeriodicalId":1,"journal":{"name":"Accounts of Chemical Research","volume":null,"pages":null},"PeriodicalIF":16.4000,"publicationDate":"2024-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11402265/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Accounts of Chemical Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15266028221149913","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/16 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0
Abstract
Purpose: Hostile aortic neck characteristics, including short length, severe suprarenal and infrarenal angulation, conicity, and large diameter, have been associated with increased risk for type Ia endoleak (T1aEL) after endovascular aneurysm repair (EVAR). This study investigates the mid-term discriminative ability of a statistical shape model (SSM) of the infrarenal aortic neck morphology compared with or in combination with conventional measurements in patients who developed T1aEL post-EVAR.
Materials and methods: The dataset composed of EVAR patients who developed a T1aEL during follow-up and a control group without T1aEL. Principal component (PC) analysis was performed using a parametrization to create an SSM. Three logistic regression models were created. To discriminate between patients with and without T1aEL, sensitivity, specificity, and the area under the receiver operating characteristic (ROC) curve (AUC) were calculated.
Results: In total, 126 patients (84% male) were included. Median follow-up time in T1aEl group and control group was 52 (31, 78.5) and 51 (40, 62.5) months, respectively. Median follow-up time was not statistically different between the groups (p=0.72). A statistically significant difference between the median PC scores of the T1aEL and control groups was found for the first, eighth, and ninth PC. Sensitivity, specificity, and AUC values for the SSM-based versus the conventional measurements-based logistic regression models were 79%, 70%, and 0.82 versus 74%, 73%, and 0.85, respectively. The model of the SSM and conventional measurements combined resulted in sensitivity, specificity, and AUC of 81%, 81%, and 0.92.
Conclusion: An SSM of the infrarenal aortic neck determines its 3-dimensional geometry. The SSM is a potential valuable tool for risk stratification and T1aEL prediction in EVAR. The SSM complements the conventional measurements of the individual preoperative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleak after standard EVAR.
Clinical impact: A statistical shape model (SSM) determines the 3-dimensional geometry of the infrarenal aortic neck. The SSM complements the conventional measurements of the individual pre-operative infrarenal aortic neck geometry by increasing the predictive value for late type Ia endoleaks post-EVAR. The SSM is a potential valuable tool for risk stratification and late T1aEL prediction in EVAR and it is a first step toward implementation of a treatment planning support tool in daily clinical practice.
期刊介绍:
Accounts of Chemical Research presents short, concise and critical articles offering easy-to-read overviews of basic research and applications in all areas of chemistry and biochemistry. These short reviews focus on research from the author’s own laboratory and are designed to teach the reader about a research project. In addition, Accounts of Chemical Research publishes commentaries that give an informed opinion on a current research problem. Special Issues online are devoted to a single topic of unusual activity and significance.
Accounts of Chemical Research replaces the traditional article abstract with an article "Conspectus." These entries synopsize the research affording the reader a closer look at the content and significance of an article. Through this provision of a more detailed description of the article contents, the Conspectus enhances the article's discoverability by search engines and the exposure for the research.