Suchit Kumar, Kyu Chan Lee, Jong-Min Kim, J. Seo, Chulhyun Lee, Chang-Hyun Oh
{"title":"Multislice B1 Mapping Method Using Magnetic Resonance Composite Spin Echo Sequences and Simultaneous Echo Refocusing","authors":"Suchit Kumar, Kyu Chan Lee, Jong-Min Kim, J. Seo, Chulhyun Lee, Chang-Hyun Oh","doi":"10.1155/2023/7642095","DOIUrl":null,"url":null,"abstract":"Radiofrequency (RF) transmit field (B1) mapping is a promising method in mitigating the B1 inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or magnitude-based B1 mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B1 mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B1 mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B1 mapping with short data acquisition time. To evaluate the performance of the proposed B1 mapping method, computational simulations were performed and compared with Morrell’s method, double angle method, and Yarnykh’s method. These results showed that the angle-to-noise ratio of the proposed B1 mapping method has wider B1 range compared to that of other B1 mapping methods. In addition, the proposed B1 mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B1 mapping method is suitable for accurately measuring B1 propagation under the condition providing reduced scan time and wider 3D coverage of B1 mapping by applying composite RF pulse and SER techniques into the phase-sensitive method.","PeriodicalId":55216,"journal":{"name":"Concepts in Magnetic Resonance Part A","volume":"36 1","pages":""},"PeriodicalIF":0.4000,"publicationDate":"2023-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Concepts in Magnetic Resonance Part A","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1155/2023/7642095","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Radiofrequency (RF) transmit field (B1) mapping is a promising method in mitigating the B1 inhomogeneity in various magnetic resonance imaging (MRI) applications. Although several phase- or magnitude-based B1 mapping methods have been proposed, these methods often require complex modeling, long acquisition time, or specialized MRI sequences. A recently introduced simultaneous echo refocusing (SER) technique can be applied in the B1 mapping method to extend the three-dimensional (3D) spatial coverage only without long data acquisition. Therefore, in this study, a multislice B1 mapping method using composite spin echo sequences and SER techniques is proposed to obtain more accurate B1 mapping with short data acquisition time. To evaluate the performance of the proposed B1 mapping method, computational simulations were performed and compared with Morrell’s method, double angle method, and Yarnykh’s method. These results showed that the angle-to-noise ratio of the proposed B1 mapping method has wider B1 range compared to that of other B1 mapping methods. In addition, the proposed B1 mapping methods were compared to the multislice iterative signal intensity mapping method in both phantom and in vivo human experiments, and there was no remarkable difference between the two methods regarding the flip angle distribution in these experiments. Based on these results, this study demonstrated that the proposed B1 mapping method is suitable for accurately measuring B1 propagation under the condition providing reduced scan time and wider 3D coverage of B1 mapping by applying composite RF pulse and SER techniques into the phase-sensitive method.
期刊介绍:
Concepts in Magnetic Resonance Part A brings together clinicians, chemists, and physicists involved in the application of magnetic resonance techniques. The journal welcomes contributions predominantly from the fields of magnetic resonance imaging (MRI), nuclear magnetic resonance (NMR), and electron paramagnetic resonance (EPR), but also encourages submissions relating to less common magnetic resonance imaging and analytical methods.
Contributors come from academic, governmental, and clinical communities, to disseminate the latest important experimental results from medical, non-medical, and analytical magnetic resonance methods, as well as related computational and theoretical advances.
Subject areas include (but are by no means limited to):
-Fundamental advances in the understanding of magnetic resonance
-Experimental results from magnetic resonance imaging (including MRI and its specialized applications)
-Experimental results from magnetic resonance spectroscopy (including NMR, EPR, and their specialized applications)
-Computational and theoretical support and prediction for experimental results
-Focused reviews providing commentary and discussion on recent results and developments in topical areas of investigation
-Reviews of magnetic resonance approaches with a tutorial or educational approach