{"title":"Description of a Harmless Method for Determining Trenbolone Acetate Together with 17B-Trenbolone in Beef","authors":"N. Furusawa","doi":"10.9734/bpi/cacb/v9/1742c","DOIUrl":null,"url":null,"abstract":"The simultaneous measurement of trenbolone acetate and 17\\(\\beta\\)-trenbolone in cattle muscle is described using an affordable, safe, and rapid sample preparation procedure followed by reversed-phase high-performance liquid chromatography (HPLC). HPLC analysis with a photo-diode array detector was carried out on a short C1 column with an isocratic mobile phase. The method was validated through analyses of spiked samples, resulting recoveries (\\(\\ge\\) 87.9%; relative standard deviations \\(\\le\\) 3.4%), analytical total time (< 20 min/sample, where, a batch of 12 samples was completed in 2 hours), and quantitation limits (\\(\\le\\) 1.8 ng/g). The proposed technique for determination of TBa and \\(\\beta\\)-TB in beef (cattle muscle) is a useful tool for the routine residue monitoring in beef and the withdrawal control of beef farm. No harmful organic solvents and reagents were used at all.","PeriodicalId":10902,"journal":{"name":"Current Advances in Chemistry and Biochemistry Vol. 9","volume":"12 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Advances in Chemistry and Biochemistry Vol. 9","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.9734/bpi/cacb/v9/1742c","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The simultaneous measurement of trenbolone acetate and 17\(\beta\)-trenbolone in cattle muscle is described using an affordable, safe, and rapid sample preparation procedure followed by reversed-phase high-performance liquid chromatography (HPLC). HPLC analysis with a photo-diode array detector was carried out on a short C1 column with an isocratic mobile phase. The method was validated through analyses of spiked samples, resulting recoveries (\(\ge\) 87.9%; relative standard deviations \(\le\) 3.4%), analytical total time (< 20 min/sample, where, a batch of 12 samples was completed in 2 hours), and quantitation limits (\(\le\) 1.8 ng/g). The proposed technique for determination of TBa and \(\beta\)-TB in beef (cattle muscle) is a useful tool for the routine residue monitoring in beef and the withdrawal control of beef farm. No harmful organic solvents and reagents were used at all.
同时测量牛肌肉中的醋酸trenbolone和17 \(\beta\) -trenbolone,使用价格合理,安全,快速的样品制备程序,然后是反相高效液相色谱(HPLC)。HPLC分析采用光电二极管阵列检测器,色谱柱为C1短柱,流动相为等等温。通过对加标样品的分析,验证了该方法的有效性,回收率为\(\ge\) 87.9%; relative standard deviations \(\le\) 3.4%), analytical total time (< 20 min/sample, where, a batch of 12 samples was completed in 2 hours), and quantitation limits (\(\le\) 1.8 ng/g). The proposed technique for determination of TBa and \(\beta\)-TB in beef (cattle muscle) is a useful tool for the routine residue monitoring in beef and the withdrawal control of beef farm. No harmful organic solvents and reagents were used at all.