The Effect of Medium-Intensity Electromagnetic Stimulation on Pelvic Floor Muscle Activity in a Young Woman—A Case Report

J. Konrad, Magdalena Grygiel
{"title":"The Effect of Medium-Intensity Electromagnetic Stimulation on Pelvic Floor Muscle Activity in a Young Woman—A Case Report","authors":"J. Konrad, Magdalena Grygiel","doi":"10.5114/PHR.2021.104599","DOIUrl":null,"url":null,"abstract":"Aims: In recent years, devices for deep electromagnetic stimulation have been implemented in clinical practice. These devices generate pulses with a frequency of 1 to 50 Hz and magnetic induction of up to 2.5 T. Due to the possibility of producing or an effective deep-penetrating mechanical vibration, electromagnetic stimulation is increasingly used in the physiotherapy of urogynecological disorders. This study aimed to analyse of the effect of deep electromagnetic stimulation on the bioelectrical activity of pelvic floor muscles in a young woman. Case report: The case of a 24-year-old woman with no diagnosed stress urinary incontinence is presented. The subject underwent electromagnetic stimulation twice a week for one month (8 treatments). A single treatment lasted 15 minutes and used a magnetic induction of 1.0 T and a frequency that varied in each successive treatment to 50 Hz. The bioelectrical activity of the pelvic floor muscles was measured before and after the study period. After completion of the treatment series, a decrease in muscle tone was found. Summary: In the case of a young woman without symptoms of stress urinary incontinence, electromagnetic stimulation (with the parameters specified in the present study) was not effective for strengthening the pelvic floor muscles. Further clinical studies should be conducted to determine the appropriate management algorithm.","PeriodicalId":88183,"journal":{"name":"The Physiotherapy review","volume":"2 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Physiotherapy review","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5114/PHR.2021.104599","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Aims: In recent years, devices for deep electromagnetic stimulation have been implemented in clinical practice. These devices generate pulses with a frequency of 1 to 50 Hz and magnetic induction of up to 2.5 T. Due to the possibility of producing or an effective deep-penetrating mechanical vibration, electromagnetic stimulation is increasingly used in the physiotherapy of urogynecological disorders. This study aimed to analyse of the effect of deep electromagnetic stimulation on the bioelectrical activity of pelvic floor muscles in a young woman. Case report: The case of a 24-year-old woman with no diagnosed stress urinary incontinence is presented. The subject underwent electromagnetic stimulation twice a week for one month (8 treatments). A single treatment lasted 15 minutes and used a magnetic induction of 1.0 T and a frequency that varied in each successive treatment to 50 Hz. The bioelectrical activity of the pelvic floor muscles was measured before and after the study period. After completion of the treatment series, a decrease in muscle tone was found. Summary: In the case of a young woman without symptoms of stress urinary incontinence, electromagnetic stimulation (with the parameters specified in the present study) was not effective for strengthening the pelvic floor muscles. Further clinical studies should be conducted to determine the appropriate management algorithm.
中等强度电磁刺激对年轻女性骨盆底肌肉活动的影响——一例报告
目的:近年来,深部电磁刺激装置已在临床应用。这些装置产生频率为1 ~ 50hz,磁感应强度高达2.5 t的脉冲,由于可以产生或有效的深穿透机械振动,电磁刺激越来越多地用于泌尿妇科疾病的物理治疗。本研究旨在分析深部电磁刺激对年轻女性骨盆底肌肉生物电活动的影响。病例报告:一个24岁的妇女没有诊断压力性尿失禁的情况下提出。受试者接受电磁刺激,每周2次,连续1个月(共8次)。单次治疗持续15分钟,磁感应强度为1.0 T,每次连续治疗的频率为50 Hz。在研究前后测量盆底肌肉的生物电活动。在完成一系列治疗后,发现肌肉张力下降。摘要:在一名没有压力性尿失禁症状的年轻女性的病例中,电磁刺激(在本研究中指定的参数)对加强盆底肌肉无效。需要进一步的临床研究来确定合适的管理方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信