{"title":"Totally intracorporeal robotic ileal ureter replacement: focus on surgical technique and outcomes.","authors":"A. Grosso, F. di Maida, A. Mari, R. Campi, A. Crisci, G. Vignolini, L. Masieri, M. Carini, A. Minervini","doi":"10.23736/S0393-2249.20.04191-0","DOIUrl":null,"url":null,"abstract":"BACKGROUND\nAim of the study was to describe our totally intracorporeal robotic ileal ureter replacement technique, reporting perioperative and mid-term results and compare it with previous similar experiences, specifically focusing on technical considerations.\n\n\nMETHODS\nThree patients were submitted to robotic ileal ureter substitution for long ureteral defects in our institution during 2019. The procedures were carried out fully intracorporeally. Two patients received a complete replacement of the urinary tract using an ileal segment, while in one patient the lower ureteral stump was maintained, and an ileal-ureter anastomosis was performed distally. Patients' baseline characteristics, as well as, perioperative and mid-term results were collected. A detailed description of the technique is reported and compared with prior similar experiences.\n\n\nRESULTS\nMedian operative time was 270 (range 240-300) min. No Clavien-Dindo complications >2 were collected. All patients experienced a fast return to oral intake and canalization. Antegrade pyelography, performed a 1-month follow-up, revealed full passage of the medium contrast in those patients submitted to complete ileal ureter replacement while, in the third one, stenosis at the level of ileal-ureter anastomoses was found.\n\n\nCONCLUSIONS\nRobotic ileal ureter replacement can be performed completely intracorporeal with optimal results and limited complication rate, in selected cases. According to our considerations, specific surgical steps are needed to reduce the risks related to this procedure, including avoiding partial ileal substitution.","PeriodicalId":49015,"journal":{"name":"Minerva Urologica E Nefrologica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-01-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Minerva Urologica E Nefrologica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.23736/S0393-2249.20.04191-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4

Abstract

BACKGROUND Aim of the study was to describe our totally intracorporeal robotic ileal ureter replacement technique, reporting perioperative and mid-term results and compare it with previous similar experiences, specifically focusing on technical considerations. METHODS Three patients were submitted to robotic ileal ureter substitution for long ureteral defects in our institution during 2019. The procedures were carried out fully intracorporeally. Two patients received a complete replacement of the urinary tract using an ileal segment, while in one patient the lower ureteral stump was maintained, and an ileal-ureter anastomosis was performed distally. Patients' baseline characteristics, as well as, perioperative and mid-term results were collected. A detailed description of the technique is reported and compared with prior similar experiences. RESULTS Median operative time was 270 (range 240-300) min. No Clavien-Dindo complications >2 were collected. All patients experienced a fast return to oral intake and canalization. Antegrade pyelography, performed a 1-month follow-up, revealed full passage of the medium contrast in those patients submitted to complete ileal ureter replacement while, in the third one, stenosis at the level of ileal-ureter anastomoses was found. CONCLUSIONS Robotic ileal ureter replacement can be performed completely intracorporeal with optimal results and limited complication rate, in selected cases. According to our considerations, specific surgical steps are needed to reduce the risks related to this procedure, including avoiding partial ileal substitution.
全体内机器人回肠输尿管置换术:手术技术与效果的探讨。
本研究的目的是描述我们的全体内机器人回肠输尿管置换技术,报告围手术期和中期的结果,并将其与以往类似的经验进行比较,特别关注技术方面的考虑。方法2019年对3例长输尿管缺损患者行机器人回肠输尿管替代术。手术完全在体内进行。2例患者采用回肠段完全替代尿路,1例患者保留下段输尿管残端,并在远端进行回肠-输尿管吻合。收集患者的基线特征以及围手术期和中期结果。报告了该技术的详细描述,并与先前的类似经验进行了比较。结果中位手术时间270 (240 ~ 300)min,无Clavien-Dindo并发症>2例。所有患者均能快速恢复口服摄入和管化。行顺行肾盂造影,随访1个月,发现完成回肠输尿管置换术的患者中造影剂完全通过,而第三例患者发现回肠输尿管吻合处狭窄。结论机器人回肠输尿管置换术在一定的病例中可以完全在体内进行,效果良好,并发症发生率低。根据我们的考虑,需要采取特定的手术步骤来减少与该手术相关的风险,包括避免部分回肠替代。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Minerva Urologica E Nefrologica
Minerva Urologica E Nefrologica UROLOGY & NEPHROLOGY-
CiteScore
5.50
自引率
0.00%
发文量
0
审稿时长
>12 weeks
期刊介绍: The journal Minerva Urologica e Nefrologica publishes scientific papers on nephrology and urology. Manuscripts may be submitted in the form of Minerva opinion editorials, editorial comments, original articles, video illustrated articles, review articles and letters to the Editor.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信