Korrosion in Trennrissen nach Rissinjektion mit Polyurethan / Reinforcement Corrosion in Separation Cracks after Injection with PUR

M. Kosalla, M. Raupach
{"title":"Korrosion in Trennrissen nach Rissinjektion mit Polyurethan / Reinforcement Corrosion in Separation Cracks after Injection with PUR","authors":"M. Kosalla, M. Raupach","doi":"10.12900/rbm14.20.5-0032","DOIUrl":null,"url":null,"abstract":"In separation cracks in RC elements (e. g. park decks), a short-term chloride exposure can already cause reinforcement corrosion. It is questionable, if a deep injection of the crack as an exclusive procedure is sufficient for effectively stopping the corrosion process. For investigating the corrosion activity during the chloride exposition and after the crack maintenance, cracked beams with crack-crossing reinforcement were fabricated. The cracks have been grout injected with PUR after a winter season of six month with a periodic chloride exposure. The anodic (element) current was recorded both before and after the injection. During chloride exposure the measured current flows were very high (sometimes > 200 μA). After the injection they slowly decreased and dropped nearly to zero in the next winter period. In the next summer the current flows increased just marginally, which seems to be mostly uncritical.","PeriodicalId":20957,"journal":{"name":"Restoration of Buildings and Monuments","volume":"107 1","pages":"51 - 64"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Restoration of Buildings and Monuments","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.12900/rbm14.20.5-0032","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

In separation cracks in RC elements (e. g. park decks), a short-term chloride exposure can already cause reinforcement corrosion. It is questionable, if a deep injection of the crack as an exclusive procedure is sufficient for effectively stopping the corrosion process. For investigating the corrosion activity during the chloride exposition and after the crack maintenance, cracked beams with crack-crossing reinforcement were fabricated. The cracks have been grout injected with PUR after a winter season of six month with a periodic chloride exposure. The anodic (element) current was recorded both before and after the injection. During chloride exposure the measured current flows were very high (sometimes > 200 μA). After the injection they slowly decreased and dropped nearly to zero in the next winter period. In the next summer the current flows increased just marginally, which seems to be mostly uncritical.
聚氨酯/钢筋在注入PUR后分离裂纹中的腐蚀
在钢筋混凝土构件(如公园甲板)的分离裂缝中,短期的氯化物暴露已经可以引起钢筋腐蚀。这是值得怀疑的,如果深注入裂缝作为一个排他的程序是足以有效地停止腐蚀过程。为了研究氯化物暴露期间和裂缝维修后的腐蚀活性,制作了带有裂缝交叉加固的裂缝梁。经过六个月的冬季定期氯化物暴露后,裂缝已经注入了PUR灌浆。在注射前后分别记录阳极(元件)电流。在氯化物暴露过程中,测量到的电流非常大(有时大于200 μA)。注射后,它们缓慢下降,在下一个冬季几乎降至零。在接下来的夏天,目前的流量只是略微增加,这似乎是不重要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信