Real time glucose monitoring system based on enzymatic nanosensor

S. N. Naveen Kumar, K. Gayithri, S. Kiran, N. Santhosh Kumar
{"title":"Real time glucose monitoring system based on enzymatic nanosensor","authors":"S. N. Naveen Kumar, K. Gayithri, S. Kiran, N. Santhosh Kumar","doi":"10.1109/ICANMEET.2013.6609324","DOIUrl":null,"url":null,"abstract":"In the present study Microcontroller based system for glucose monitoring is developed. The output of the conductometric nanosensor is taken as input to the glucose monitoring system. The output of the sensor varies with respect to the variation in glucose concentration. The output of the sensor is amplified by using an amplifier designed using IC 741. Amplified signal is fed to the input port “PORT A” of PIC 16F877 microcontroller. Microcontroller processes and analyses the amplified voltage and the result will be displayed on 16×2 LCD interfaced to it. An LCD displays various glucose concentration based on the condition as LOW, NORMAL, and HIGH.","PeriodicalId":13708,"journal":{"name":"International Conference on Advanced Nanomaterials & Emerging Engineering Technologies","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2013-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Conference on Advanced Nanomaterials & Emerging Engineering Technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICANMEET.2013.6609324","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In the present study Microcontroller based system for glucose monitoring is developed. The output of the conductometric nanosensor is taken as input to the glucose monitoring system. The output of the sensor varies with respect to the variation in glucose concentration. The output of the sensor is amplified by using an amplifier designed using IC 741. Amplified signal is fed to the input port “PORT A” of PIC 16F877 microcontroller. Microcontroller processes and analyses the amplified voltage and the result will be displayed on 16×2 LCD interfaced to it. An LCD displays various glucose concentration based on the condition as LOW, NORMAL, and HIGH.
基于酶促纳米传感器的葡萄糖实时监测系统
本研究开发了一种基于单片机的血糖监测系统。电导纳米传感器的输出作为葡萄糖监测系统的输入。传感器的输出值随葡萄糖浓度的变化而变化。传感器的输出通过使用IC 741设计的放大器进行放大。放大后的信号被送入pic16f877微控制器的输入端口“port A”。单片机对放大后的电压进行处理和分析,结果显示在16×2液晶显示器上。LCD显示各种葡萄糖浓度的基础上的条件为低,正常,和高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信