Design and Diagnosis of current faults in electrical power systems of permanant magnet synchrones machine

Fatima Zohra Hamdi Pacha, A. Herizi, Walid Amri, Abdessattar Ben Amor
{"title":"Design and Diagnosis of current faults in electrical power systems of permanant magnet synchrones machine","authors":"Fatima Zohra Hamdi Pacha, A. Herizi, Walid Amri, Abdessattar Ben Amor","doi":"10.1109/IC_ASET53395.2022.9765862","DOIUrl":null,"url":null,"abstract":"This paper focuses on the diagnosis of electrical faults in electrical drives based on the permanent magnet synchronous machine (PMSM) which is supplied by a system of voltages delivered by a voltage inverter, this is controlled by the hysteresis strategy with three reference currents. High current or cut-off can cause problems for three-phase equipment and the most common impact of these faults is overheating of the equipment and consequently degradation of electrical insulation and reduction of service life. A modeling of the system performance in the healthy and faulty machine cases has been simulated. In this paper, firstly, the system is analyzed for the different supply current faults of types: unbalance and current break. Then, the fault detection of the permanent magnet synchronous machine can be illustrated by the evolution of the parameters that describe the electrical and mechanical characteristics of the machine. The results of the simulation are realized by Simulink MATLAB.","PeriodicalId":6874,"journal":{"name":"2022 5th International Conference on Advanced Systems and Emergent Technologies (IC_ASET)","volume":"1 1","pages":"204-209"},"PeriodicalIF":0.0000,"publicationDate":"2022-03-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2022 5th International Conference on Advanced Systems and Emergent Technologies (IC_ASET)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/IC_ASET53395.2022.9765862","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

This paper focuses on the diagnosis of electrical faults in electrical drives based on the permanent magnet synchronous machine (PMSM) which is supplied by a system of voltages delivered by a voltage inverter, this is controlled by the hysteresis strategy with three reference currents. High current or cut-off can cause problems for three-phase equipment and the most common impact of these faults is overheating of the equipment and consequently degradation of electrical insulation and reduction of service life. A modeling of the system performance in the healthy and faulty machine cases has been simulated. In this paper, firstly, the system is analyzed for the different supply current faults of types: unbalance and current break. Then, the fault detection of the permanent magnet synchronous machine can be illustrated by the evolution of the parameters that describe the electrical and mechanical characteristics of the machine. The results of the simulation are realized by Simulink MATLAB.
永磁同步电机电力系统电流故障的设计与诊断
本文研究了基于电压逆变器供电系统的永磁同步电机(PMSM)的电气故障诊断,该系统采用三个参考电流的磁滞控制策略。大电流或切断会导致三相设备出现问题,这些故障最常见的影响是设备过热,从而导致电气绝缘退化和使用寿命缩短。对系统在正常机和故障机两种情况下的性能进行了仿真。本文首先对系统中不同类型的供电电流故障进行了分析:不平衡故障和断流故障。然后,可以通过描述电机电气和机械特性的参数的演变来说明永磁同步电机的故障检测。仿真结果通过Simulink MATLAB实现。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信