{"title":"Voltammetric folic acid sensor based on nickel ferrite nanoparticles modified-screen printed graphite electrode","authors":"P. Mohammadzadeh Jahani, Mohammad Reza Aflatoonian","doi":"10.5599/jese.1607","DOIUrl":null,"url":null,"abstract":"In this study, an electrochemical sensor for the quantification of folic acid with voltam­metric detection in physiological conditions was constructed. For this purpose, nickel ferrite (NiFe2O4) nanoparticles were used to modify the surface of a screen-printed graphite electrode (NiFe2O4/SPGE) and applied in the determination of folic acid. The modified electrode displays a strong electrochemical response to folic acid. Folic acid was determined electrochemically using the differential pulse voltammetry (DPV) technique with a detection limit of 0.09±0.001 µM in 0.2–147.0 µM linear range in phosphate buffer solution (PBS) at pH 7.0 with this NiFe2O4/SPGE sensor, which has the best electron transfer rate. Also, the sensitivity of the modified electrode was obtained as 0.1139 µA µM-1. The NiFe2O4/SPGE sensor was successfully applied for the determination of folic acid in real samples.","PeriodicalId":15660,"journal":{"name":"Journal of Electrochemical Science and Engineering","volume":"100 1","pages":""},"PeriodicalIF":2.9000,"publicationDate":"2022-11-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Electrochemical Science and Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5599/jese.1607","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ELECTROCHEMISTRY","Score":null,"Total":0}
引用次数: 1

Abstract

In this study, an electrochemical sensor for the quantification of folic acid with voltam­metric detection in physiological conditions was constructed. For this purpose, nickel ferrite (NiFe2O4) nanoparticles were used to modify the surface of a screen-printed graphite electrode (NiFe2O4/SPGE) and applied in the determination of folic acid. The modified electrode displays a strong electrochemical response to folic acid. Folic acid was determined electrochemically using the differential pulse voltammetry (DPV) technique with a detection limit of 0.09±0.001 µM in 0.2–147.0 µM linear range in phosphate buffer solution (PBS) at pH 7.0 with this NiFe2O4/SPGE sensor, which has the best electron transfer rate. Also, the sensitivity of the modified electrode was obtained as 0.1139 µA µM-1. The NiFe2O4/SPGE sensor was successfully applied for the determination of folic acid in real samples.
镍铁氧体纳米颗粒修饰的丝网印刷石墨电极伏安式叶酸传感器
本研究构建了生理条件下伏安法测定叶酸的电化学传感器。为此,利用镍铁氧体(NiFe2O4)纳米颗粒修饰丝网印刷石墨电极(NiFe2O4/SPGE)的表面,并将其应用于叶酸的测定。修饰电极对叶酸表现出较强的电化学响应。采用差分脉冲伏安法(DPV)测定叶酸,在pH 7.0的磷酸盐缓冲溶液(PBS)中,在0.2 ~ 147.0µM线性范围内检测限为0.09±0.001µM,该传感器具有最佳的电子传递速率。修饰电极的灵敏度为0.1139µAµM-1。成功地将NiFe2O4/SPGE传感器应用于实际样品中叶酸的测定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
27.30%
发文量
90
审稿时长
6 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信