Real-Time Measurement of Personal Exposure to Airborne Nano-Objects with the DiSCmini/Echtzeitmessung der persönlichen Exposition gegenüber luftgetragenen Nanoobjekten mit dem DISCmini. Teil 1: Arbeitsprinzip und Leistungsverhalten im Labortest

IF 0.1 4区 环境科学与生态学 Q4 ENGINEERING, CIVIL
Sébastien Bau, Raphaël Payer, Olivier Witschger, Sabyne Audignon, Louis Galey
{"title":"Real-Time Measurement of Personal Exposure to Airborne Nano-Objects with the DiSCmini/Echtzeitmessung der persönlichen Exposition gegenüber luftgetragenen Nanoobjekten mit dem DISCmini. Teil 1: Arbeitsprinzip und Leistungsverhalten im Labortest","authors":"Sébastien Bau, Raphaël Payer, Olivier Witschger, Sabyne Audignon, Louis Galey","doi":"10.37544/0949-8036-2023-03-04-37","DOIUrl":null,"url":null,"abstract":"The use of real-time measurement techniques for objectifying occupational exposure situations is rapidly expanding. However, in many cases, the calibration data provided by manufacturers must be completed by aerosols representative of those present in occupational environments. Present on the market for about ten years, the DiSCmini device is one of the few devices that measures personal exposure to nanometer sized aerosols in real time. Laboratory work conducted on 13 devices provided knowledge about their metrological performance. The experimental data, established for a large range of test aerosols, indicate that this instrument tends to overestimate concentration by 30 to 100 %, and underestimate particle diameter by 20 to 30 %.","PeriodicalId":55125,"journal":{"name":"Gefahrstoffe Reinhaltung der Luft","volume":"5 1","pages":""},"PeriodicalIF":0.1000,"publicationDate":"2023-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Gefahrstoffe Reinhaltung der Luft","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.37544/0949-8036-2023-03-04-37","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 0

Abstract

The use of real-time measurement techniques for objectifying occupational exposure situations is rapidly expanding. However, in many cases, the calibration data provided by manufacturers must be completed by aerosols representative of those present in occupational environments. Present on the market for about ten years, the DiSCmini device is one of the few devices that measures personal exposure to nanometer sized aerosols in real time. Laboratory work conducted on 13 devices provided knowledge about their metrological performance. The experimental data, established for a large range of test aerosols, indicate that this instrument tends to overestimate concentration by 30 to 100 %, and underestimate particle diameter by 20 to 30 %.
实施《员工实现空中纳米目标的后续措施》需要DiSCmini和实时数据第一部分:实验工作原则与表现
实时测量技术用于客观化职业暴露情况的使用正在迅速扩大。然而,在许多情况下,制造商提供的校准数据必须由职业环境中具有代表性的气溶胶来完成。DiSCmini设备在市场上已经存在了大约十年,它是为数不多的能够实时测量个人暴露于纳米尺寸气溶胶的设备之一。对13个设备进行的实验室工作提供了有关其计量性能的知识。为大范围的测试气溶胶建立的实验数据表明,该仪器倾向于高估浓度30%至100%,低估颗粒直径20%至30%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Gefahrstoffe Reinhaltung der Luft
Gefahrstoffe Reinhaltung der Luft 工程技术-工程:环境
CiteScore
0.50
自引率
33.30%
发文量
71
审稿时长
6-12 weeks
期刊介绍: - Expertenwissen Luftemissionen und -reinhaltung. - Filtertechniken, Lösungen zur Luftreinhaltung und Emissionsvermeidung. - Aktueller Diskurs der Community.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信