Maria-Celeste T. Diniz, André Fernando Oliveira, Orlando Fatibello-Filho
{"title":"Turbidimetric determination of orthophosphate in digested plant material by flow-injection analysis","authors":"Maria-Celeste T. Diniz, André Fernando Oliveira, Orlando Fatibello-Filho","doi":"10.1002/1098-2728(2000)12:5<236::AID-LRA3>3.0.CO;2-L","DOIUrl":null,"url":null,"abstract":"<p>A simple, fast, and low-cost flow-injection system is proposed for the determination of orthophosphate in digested plant material. The determination is based on the precipitation reaction of orthophosphate with 0.05 mol L<sup>−1</sup> zinc solution in 0.05 mol L<sup>−1</sup> triethanolamine buffer (TEA/TEAH<sup>+</sup>, pH 6.0) solution containing 0.025% (w/v) poly-(vinylalcohol). The zinc orthophosphate suspension produced was directly measured at 410 nm. Under the best experimental conditions, orthophosphate was determinated in the concentration range from 5 to 60 mg P L<sup>−1</sup>, and the relative standard deviations were less than 1.6% for 10 and 20 mg P L<sup>−1</sup> solutions (n = 9). The analytical frequency was 180 h<sup>−1</sup>. The results obtained using the proposed FIA procedure and those obtained using a standard spectrophotometric procedure agree at the 95% confidence level. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:236–240, 2000</p>","PeriodicalId":100863,"journal":{"name":"Laboratory Robotics and Automation","volume":"12 5","pages":"236-240"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/1098-2728(2000)12:5<236::AID-LRA3>3.0.CO;2-L","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratory Robotics and Automation","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/1098-2728%282000%2912%3A5%3C236%3A%3AAID-LRA3%3E3.0.CO%3B2-L","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 3
Abstract
A simple, fast, and low-cost flow-injection system is proposed for the determination of orthophosphate in digested plant material. The determination is based on the precipitation reaction of orthophosphate with 0.05 mol L−1 zinc solution in 0.05 mol L−1 triethanolamine buffer (TEA/TEAH+, pH 6.0) solution containing 0.025% (w/v) poly-(vinylalcohol). The zinc orthophosphate suspension produced was directly measured at 410 nm. Under the best experimental conditions, orthophosphate was determinated in the concentration range from 5 to 60 mg P L−1, and the relative standard deviations were less than 1.6% for 10 and 20 mg P L−1 solutions (n = 9). The analytical frequency was 180 h−1. The results obtained using the proposed FIA procedure and those obtained using a standard spectrophotometric procedure agree at the 95% confidence level. © 2000 John Wiley & Sons, Inc. Lab Robotics and Automation 12:236–240, 2000
流动注射分析法浊度法测定消化植物原料中正磷酸盐
提出了一种简单、快速、低成本的流动注射系统,用于测定消化植物材料中的正磷酸盐。在0.05 mol L−1的三乙醇胺缓冲液(TEA/TEAH+, pH 6.0)含0.025% (w/v)聚乙烯醇溶液中,正磷酸盐与0.05 mol L−1锌溶液沉淀反应。制备的正磷酸锌悬浮液在410 nm处直接测定。在最佳实验条件下,正磷酸盐的测定浓度范围为5 ~ 60 mg P L−1,10和20 mg P L−1溶液(n = 9)的相对标准偏差小于1.6%,分析频率为180 h−1。使用建议的FIA程序获得的结果和使用标准分光光度法程序获得的结果在95%的置信水平上一致。©2000 John Wiley &儿子,Inc。机械工程学报,2009 (12):356 - 356
本文章由计算机程序翻译,如有差异,请以英文原文为准。