Evaluation of the compatibility of Phoenix 100 and Microflex LT MALDI-TOF MS systems in the identification of routinely isolated microorganisms in the clinic microbiology laboratory

IF 0.1 Q4 OTORHINOLARYNGOLOGY
C. Çelik, E. Uysal, Uğur Tutar, Rahşan Erturk, M. Z. Bakıcı, M. G. Gozel
{"title":"Evaluation of the compatibility of Phoenix 100 and Microflex LT MALDI-TOF MS systems in the identification of routinely isolated microorganisms in the clinic microbiology laboratory","authors":"C. Çelik, E. Uysal, Uğur Tutar, Rahşan Erturk, M. Z. Bakıcı, M. G. Gozel","doi":"10.1515/labmed-2015-0105","DOIUrl":null,"url":null,"abstract":"Abstract Background: Matrix-assisted laser desorption/ionization time-of flight mass spectrometry (MALDI-TOF MS) is a quick, reliable, and efficient system for identifying microorganisms. Many centers that use the Phoenix 100 system today may adopt a MALDI-TOF MS system in the future. Our laboratory recently undertook this pivot. The present study evaluates the reproducibility of species identifications made by the Phoenix 100 and MALDI-TOF MS systems, during a period of transitioning laboratory instrumentation. Methods: Eight hundred and twelve microbial isolates, from aerobic cultures of different clinical samples, were identified simultaneously with Phoenix 100 (Becton Dickinson, Sparks, MD, USA) and a Microflex LT MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) devices. Results: Both systems made identical species assignments for 98.9%, 92.1%, 95.1%, and 93.1% of Gram-negative isolates, catalase-positive Gram-positive cocci isolates, catalase-negative Gram-positive cocci isolates, and Candida isolates, respectively. Conclusions: Identifications made by two instruments commonly used in microbiology laboratories, the Phoenix 100 and the Microflex LT MALDI-TOF MS, are highly consistent.","PeriodicalId":49926,"journal":{"name":"Laboratoriumsmedizin-Journal of Laboratory Medicine","volume":"105 1","pages":"183 - 189"},"PeriodicalIF":0.1000,"publicationDate":"2016-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Laboratoriumsmedizin-Journal of Laboratory Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1515/labmed-2015-0105","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"OTORHINOLARYNGOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Abstract Background: Matrix-assisted laser desorption/ionization time-of flight mass spectrometry (MALDI-TOF MS) is a quick, reliable, and efficient system for identifying microorganisms. Many centers that use the Phoenix 100 system today may adopt a MALDI-TOF MS system in the future. Our laboratory recently undertook this pivot. The present study evaluates the reproducibility of species identifications made by the Phoenix 100 and MALDI-TOF MS systems, during a period of transitioning laboratory instrumentation. Methods: Eight hundred and twelve microbial isolates, from aerobic cultures of different clinical samples, were identified simultaneously with Phoenix 100 (Becton Dickinson, Sparks, MD, USA) and a Microflex LT MALDI-TOF MS (Bruker Daltonics, Bremen, Germany) devices. Results: Both systems made identical species assignments for 98.9%, 92.1%, 95.1%, and 93.1% of Gram-negative isolates, catalase-positive Gram-positive cocci isolates, catalase-negative Gram-positive cocci isolates, and Candida isolates, respectively. Conclusions: Identifications made by two instruments commonly used in microbiology laboratories, the Phoenix 100 and the Microflex LT MALDI-TOF MS, are highly consistent.
评价Phoenix 100与Microflex LT MALDI-TOF质谱系统在临床微生物实验室常规分离微生物鉴定中的兼容性
背景:基质辅助激光解吸/电离飞行时间质谱(MALDI-TOF MS)是一种快速、可靠、高效的微生物鉴定系统。许多目前使用Phoenix 100系统的中心将来可能会采用MALDI-TOF MS系统。我们的实验室最近进行了这项实验。在实验室仪器过渡期间,本研究评估了Phoenix 100和MALDI-TOF MS系统进行物种鉴定的可重复性。方法:采用Phoenix 100 (Becton Dickinson, Sparks, MD, USA)和Microflex LT MALDI-TOF MS (Bruker Daltonics, Bremen, Germany)设备同时对来自不同临床样品的好氧培养的812株微生物进行鉴定。结果:两种系统分别对革兰氏阴性菌、过氧化氢酶阳性革兰氏阳性球菌、过氧化氢酶阴性革兰氏阳性球菌和念珠菌分离株的鉴定结果相同,分别为98.9%、92.1%、95.1%和93.1%。结论:微生物实验室常用的两种仪器Phoenix 100和Microflex LT MALDI-TOF MS鉴定结果高度一致。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.80
自引率
0.00%
发文量
1
审稿时长
>12 weeks
期刊介绍: Information not localized
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信