PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER

Taufiqurahman Taufiqurahman, A. A. Harnawan, I. Sugriwan
{"title":"PROTOTYPE OF THE WELL WATER CONDUCTIVITY SENSOR SYSTEM BASED MICROCONTROLLER","authors":"Taufiqurahman Taufiqurahman, A. A. Harnawan, I. Sugriwan","doi":"10.18860/neu.v10i2.4895","DOIUrl":null,"url":null,"abstract":"Electrical conductivity is one of the water quality parameters. The value of conductivity is an early indication of water pollution. Standard of the water conductivity value according to WHO should be less than 400 μS/cm. The prototype of the well-water conductivity sensor system consists of the power supply, temperature sensor circuit, conductivity sensor circuit, Arduino UNO microcontroller, 16x2 I2C LCD characters and the conversion equation. Therefore, It presents the conductivity value at various temperature and conductivity at 25oC by conversion equation. Furthermore, it measured the conductivity of water within 15.24 - 1031.60 μS/cm with error 0.39 – 21.48 μS/cm and the temperature of water within  20.10 – 50.20oC with error 0.13 – 0.72oC.  The test of measurement from 11 sample points in the Pesayangan Martapura and Antasan Senor East Martapura, Banjar, South Kalimantan, Indonesia showed the conductivity of the well-water at the actual temperature was at the range of 128.50 – 364.51 μS/cm and the 161.97 – 364.51 μS/cm at 25oC.","PeriodicalId":17685,"journal":{"name":"Jurnal Neutrino","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Neutrino","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18860/neu.v10i2.4895","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Electrical conductivity is one of the water quality parameters. The value of conductivity is an early indication of water pollution. Standard of the water conductivity value according to WHO should be less than 400 μS/cm. The prototype of the well-water conductivity sensor system consists of the power supply, temperature sensor circuit, conductivity sensor circuit, Arduino UNO microcontroller, 16x2 I2C LCD characters and the conversion equation. Therefore, It presents the conductivity value at various temperature and conductivity at 25oC by conversion equation. Furthermore, it measured the conductivity of water within 15.24 - 1031.60 μS/cm with error 0.39 – 21.48 μS/cm and the temperature of water within  20.10 – 50.20oC with error 0.13 – 0.72oC.  The test of measurement from 11 sample points in the Pesayangan Martapura and Antasan Senor East Martapura, Banjar, South Kalimantan, Indonesia showed the conductivity of the well-water at the actual temperature was at the range of 128.50 – 364.51 μS/cm and the 161.97 – 364.51 μS/cm at 25oC.
基于单片机的井水电导率传感器系统原型
电导率是水质参数之一。电导率值是水污染的早期指标。WHO规定的水电导率值应小于400 μS/cm。井水电导率传感器系统样机由电源、温度传感器电路、电导率传感器电路、Arduino UNO单片机、16x2 I2C液晶显示字符和转换方程组成。因此,用转换方程表示了不同温度下的电导率值和25oC时的电导率。测得15.24 ~ 1031.60 μS/cm范围内的水电导率,误差为0.39 ~ 21.48 μS/cm;测得20.10 ~ 50.20oC范围内的水温度,误差为0.13 ~ 0.72oC。在印度尼西亚南加里曼丹班贾尔的Pesayangan Martapura和Antasan Senor East Martapura的11个样点进行了测试,结果表明,井水在实际温度下的电导率为128.50 ~ 364.51 μS/cm,在25℃时的电导率为161.97 ~ 364.51 μS/cm。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信