Construction of partial discharge measurement system under influence of cylindrical metal particle in transformer oil

K. Azmi, D. Ishak, M. Kamarol, A. Zuhairi
{"title":"Construction of partial discharge measurement system under influence of cylindrical metal particle in transformer oil","authors":"K. Azmi, D. Ishak, M. Kamarol, A. Zuhairi","doi":"10.1109/SCORED.2016.7810071","DOIUrl":null,"url":null,"abstract":"This paper reported the construction of partial discharge measurement system under influence of cylindrical metal particle in transformer oil. The partial discharge of free cylindrical metal particle in the uniform electric field under AC applied voltage was studied in this paper. The partial discharge inception voltage (PDIV) for the single particle was measure to be 11kV. The typical waveform of positive PD and negative PD was also obtained. The result shows that the magnitude of negative PD is higher compared to positive PD. The observation on cylindrical metal particle movement revealed that there were a few stages of motion process involved.","PeriodicalId":6865,"journal":{"name":"2016 IEEE Student Conference on Research and Development (SCOReD)","volume":"78 1","pages":"1-4"},"PeriodicalIF":0.0000,"publicationDate":"2016-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2016 IEEE Student Conference on Research and Development (SCOReD)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/SCORED.2016.7810071","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 4

Abstract

This paper reported the construction of partial discharge measurement system under influence of cylindrical metal particle in transformer oil. The partial discharge of free cylindrical metal particle in the uniform electric field under AC applied voltage was studied in this paper. The partial discharge inception voltage (PDIV) for the single particle was measure to be 11kV. The typical waveform of positive PD and negative PD was also obtained. The result shows that the magnitude of negative PD is higher compared to positive PD. The observation on cylindrical metal particle movement revealed that there were a few stages of motion process involved.
变压器油中圆柱形金属颗粒影响下局部放电测量系统的构建
本文报道了变压器油中圆柱形金属颗粒影响下局部放电测量系统的构建。本文研究了在交流电压作用下,自由圆柱形金属颗粒在均匀电场中的局部放电现象。测定了单颗粒局部放电起始电压(PDIV)为11kV。得到了PD阳性和PD阴性的典型波形。结果表明,与正PD相比,负PD的强度更高。通过对圆柱形金属颗粒运动的观察,发现其运动过程包含几个阶段。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信