Y. Kataoka, Masakazu Takayama, Y. Matsushima, Y. Anazawa
{"title":"Comparison of three magnet array-type rotors in surface permanent magnet-type vernier motor","authors":"Y. Kataoka, Masakazu Takayama, Y. Matsushima, Y. Anazawa","doi":"10.11142/JICEMS.2013.2.1.1","DOIUrl":null,"url":null,"abstract":"Surface permanent magnet-type vernier motors with three magnet array-type rotors (parallel magnetized type, repulsion type, and Halbach type) are compared based on the pull-out torque. It was clarified that increasing the rotor radius increases the pull-out torque at a fixed three-phase alternating voltage. The mechanism for the pull-out torque increase on each magnet array type was different, when the effects of the increase were analyzed based on an induced electromotive force and a synchronous reactance. As a result, the design of the Halbach-type rotor was found to be especially effective for achieving high pull-out torque, because this array type achieves a large induced electromotive force E0 and a small synchronous reactance xs.","PeriodicalId":6398,"journal":{"name":"2012 15th International Conference on Electrical Machines and Systems (ICEMS)","volume":"91 1","pages":"1-6"},"PeriodicalIF":0.0000,"publicationDate":"2012-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"17","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"2012 15th International Conference on Electrical Machines and Systems (ICEMS)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11142/JICEMS.2013.2.1.1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 17
Abstract
Surface permanent magnet-type vernier motors with three magnet array-type rotors (parallel magnetized type, repulsion type, and Halbach type) are compared based on the pull-out torque. It was clarified that increasing the rotor radius increases the pull-out torque at a fixed three-phase alternating voltage. The mechanism for the pull-out torque increase on each magnet array type was different, when the effects of the increase were analyzed based on an induced electromotive force and a synchronous reactance. As a result, the design of the Halbach-type rotor was found to be especially effective for achieving high pull-out torque, because this array type achieves a large induced electromotive force E0 and a small synchronous reactance xs.